Kepware Drivers
A Drivers
ABB Totalflow Driver
Overview
Setup
Channel Properties
Channel Properties — General
Channel Properties — Serial Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Channel Properties — Communication Serialization
Device Properties
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Tag Generation
Device Properties — Time Synchronization
Device Properties — Settings
Device Properties — EFM Meters
Device Properties — Trend
Automatic Tag Database Generation
Data Types Description
Address Descriptions
Characteristic Address Descriptions
DB2 Protocol Address Descriptions
Trend Address Descriptions
Statistics Items
EFM Pointer Rollback
Error Descriptions
A communication error occurred while <reading/writing> address <tag address> on device <device name>: <verbose communication error>.
A communication error occurred while reading address <tag address> on device <device name>: Device did not respond.
A communication error occurred while reading address <tag address> on device <device name>: General remote NACK error.
A communication error occurred while reading address <tag address> on device <device name>: Illegal register read or write.
A communication error occurred while reading address <tag address> on device <device name>: Invalid data structure.
A communication error occurred while reading address <tag address> on device <device name>: Received data had a CRC error.
A communication error occurred while reading address <tag address> on device <device name>: Transaction ID did not match.
A communication error occurred while reading register block <tag address 1 - tag address 2> on device <device name>: Invalid VCB Array.
Bit index out of range for register address <tag address> on device <device name>.
Configuration Invalid XML document: XML Validation Error. Failed to parse.
Could not write data for trend file <trend file> on device <device> to disk: <reason>.
<Device name> - Failed to read EFM pointer file. <Extended error>.
<Device name> - Failed to read trend pointer file. <Extended error>.
<Device name> - Failed to write EFM pointer file. <Extended error>.
<Device name> - Failed to write trend pointer file. <Extended error>.
Device <device name> is not responding.
EFM meter <meter name> on device <device name> is invalid.
Max. sequence number of 0 reported from device. Cancelling <EFM history type> poll.
EFM type mismatch for meter <meter name> on device <device name>. The meter is configured for <meter type> in the server but it is a <meter type> meter in the device.
Extra data revision not supported. The EFM output file for <meter name> on device <device name> will be missing some data. Extra data revision = <extra data revision>, extra data size = <extra data size>
Extra data size is 0 bytes. The EFM output file for <meter name> on device <device name> will be missing some data. Extra data revision = <extra data revision>, extra data size = <extra data size>
Failed to send communication request for address <tag address> on device <device name>.
Invalid address for register block <App>.<Array>.<Register X> - <App>.<Array>.<Register Y> on device <device name>.
Invalid data type <data type> for address <tag address> for device <device name>.
Register blocking error, verify that data type <data type> is valid for address <tag address> on device <device name>.
Serialization of EFM data to temporary file <file name> failed. Reason: <file I/O error>.
The rollback value has been adjusted to match the archive size because it exceeded the size of the archive. | Adjusted rollback = <size>, archive = <name>.
Trend file configuration changed for trend file <trend file> on device <device>. Old data moved to <file name>. New data written to <file name>.
Trend file <trend file name> does not exist on device <device name>.
Trend upload expected new records for trend file <trend file> on device <device name>, but no records were retrieved.
Unable to automatically generate trend tags for device '<device name>'. Reason: No trend files found on device.
Unable to load TCI Toolkit extradata.ini file, EFM feature may not work properly.
Unable to write to <address> on device <device name>.
Acroloop CIP Ethernet
Overview
Device Setup
Channel Properties — General
Channel Properties — Ethernet Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Communication Parameters
Device Properties — Timing
Device Properties — Auto-Demotion
Automatic Tag Generation
Address Descriptions
Error Codes
Encapsulation Error Codes
CIP Error Codes
0x0001 Extended Error Codes
0x001F Extended Error Codes
Error Descriptions
Encapsulation error occurred during a request to device '<IP address>'
Memory could not be allocated for tag with address '<address'> on device '<device name>'
Read request for '<count>' elements starting at '<address>' on device '<device>' failed due to a framing error
Read request for tag '<tag address>' on device '<device name>' failed due to a framing error
Unable to bind to adapter: '<name>'. Connect failed
Unable to read '<count>' elements starting at '<address>' on device '<device name>'
Unable to read tag '<tag address>' on device '<device name>'
Unable to write to tag '<tag address>' on device '<device name>'
Winsock initialization failed (OS Error = <socket>)
Write request for tag '<tag address>' on device '<device name>' failed due to a framing error
Advanced Simulator
Overview
External Dependencies
Setup
Channel Properties — General
Channel Properties — Write Optimizations
Channel Properties — Advanced
Channel Properties — Data Source Settings
Device Properties — General
Device Properties — Scan Mode
Device Properties — Table Selection
Device Properties — Timing
Data Types Description
Address Descriptions
Error Descriptions
Address Validation
Missing address.
Device address <address> contains a syntax error.
Data Type <type> is not valid for device address <address>.
Device address <address> is read only.
Array support is not available for the specified address: <address>.
Device Status Messages
Write request rejected on read-only item reference <channel name><device name><address>.
Advanced Simulator Driver Specific Messages
Unable to retrieve table names.
Unable to retrieve table column names.
Unable to retrieve table row count.
Runtime
Unable to connect to data source on channel <channel name>.
Data source <data source name> is configured as Read Only (all writes will be rejected).
Unable to open recordset on device <device name>.
Unable to query recordset on device <device name>.
Unable to retrieve database value for tag <tag address> on device <device name>.
Unable to read internal tag <tag address> on device <device name>.
Unable to write to internal tag <tag address> on device <device name>
Allen-Bradley Bulletin 900
Overview
Setup
Channel Setup
Channel Properties — General
Channel Properties — Serial Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Setup
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Tag Generation
Device Properties — Value Scaling
Automatic Tag Database Generation
Device <device name> is not responding.
Address Descriptions
Error Descriptions
Address <address> is out of range for the specified device or register.
Communications error on <channel name> [<error mask>].
COMn does not exist.
COMn is in use by another application.
Data Type <type> is not valid for device address <address>.
Device address <address> contains a syntax error.
Device address <address> is not supported by model <model name>.
Device address <address> is read only.
Device <device name> is not responding.
Device <device name> responded with error.(Tag <tag address>).
Error opening COMn.
Missing address.
Unable to generate a tag database for device <device name>.
Unable to set comm parameters on COMn.
Unable to write to <address> on device <device name>.
Allen-Bradley 900 Error Code List
Allen-Bradley 1609 UPS
Overview
Setup
Channel Properties — General
Channel Properties — Ethernet Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Device Properties — Tag Generation
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Communication Parameters
Device Properties — Community Setup
Device Properties — Maximum Request Size
Device Properties — Error Handling
Automatic Tag Database Generation
Data Types Description
Address Descriptions
Address Descriptions
Address Descriptions for Bulletin 1609 Model
Trap Messages
Error Descriptions
Address Validation
Missing address.
Device address <address> contains a syntax error.
Address <address> is out of range for the specified device or register.
Device address <address> is not supported by model <model name>.
Data type <type> is not valid for device address <address>.
Device address <address> is read only.
Communication Messages
Winsock V1.1 or higher must be installed.
Device Status Messages
Device <device name> is not responding.
Unable to write to <address> on device <device name>.
Device Specific Messages
Failed to get response from device <device> for block tag <tag>.
Failed to get response from device <device> for tag <tag>.
Failed to send request for address <address> in device <device>.
Failed to send request for block tag <tag> in device <device>.
The address <address> is configured as Read Only in device <device>.
The request size or the returned value for object ID <ID> in device <device> is too large.
The returned/write value for block ID <ID> in device <device> is too large.
The value written is not allowed at address <address> in device <device>.
UPS returned 'general error' for <address> in device <device>.
UPS returned 'no such name' error on block tag <tag> in device <device>. Deactivating block tag <tag>.
UPS returned 'no such name' error on <tag> in device <device>. Deactivating <tag>.
UPS returned unknown error for block tag <tag> in device <device>. Error number = <number>.
UPS returned unknown error for <address> in device <device>. Error number = <number>.
Automatic Tag Database Generation Messages
Unable to generate a tag database for device <device name>.
Allen-Bradley ControlLogix Ethernet
Overview
Setup
Channel Properties — General
Channel Properties — Ethernet Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — Identification
Operating Mode
Device Properties — Scan Mode
Tag Counts
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Tag Generation
Device Properties — Logix Communications Parameters
Device Properties — Logix Options
Device Properties — Logix Database Settings
Device Properties — ENI DF1/DH+/ControlNet Gateway Communications Parameters
Block Writes
Device Properties — SLC 500 Slot Configuration
SLC 500 Modular I/O Selection Guide
Configuration API ControlLogix Examples
Enumerations
Device Model Enumerations
Configuration API — Slot Configuration
Automatic Tag Database Generation
Tag Hierarchy
Controller-to-Server Name Conversions
Preparing for Automatic Tag Database Generation
Performance Optimizations
Optimizing Communications
Optimizing the Application
Performance Statistics and Tuning
Performance Tuning Example
Data Types Description
Default Data Type Conditions
Address Descriptions
Logix Addressing
MicroLogix Addressing
SLC 500 Fixed I/O Addressing
SLC 500 Modular I/O Addressing
PLC-5 Series Addressing
Logix Tag-Based Addressing
Logix Tag-Based Addressing
Address Formats
Tag Scope
Internal Tags
Predefined Term Tags
Address Usage
Addressing Atomic Data Types
Addressing Structure Data Types
Addressing STRING Data Type
Ordering of Logix Array Data
Logix Advanced Addressing
Advanced Addressing: BOOL
Advanced Addressing: SINT
Advanced Addressing: INT
Advanced Addressing: DINT
Advanced Addressing: LINT
Advanced Addressing: REAL
Advanced Addressing: USINT
Advanced Addressing: UINT
Advanced Addressing: UDINT
Advanced Addressing: ULINT
Advanced Addressing: LREAL
Advanced Addressing: TIME32
Advanced Addressing: TIME
Advanced Addressing: LTIME
DF1 File Listing
File Listing
Output Files
Input Files
Status Files
Binary Files
Timer Files
Counter Files
Control Files
Integer Files
Float Files
ASCII Files
String Files
BCD Files
Long Files
MicroLogix PID Files
PID Files
MicroLogix Message Files
Message Files
Block Transfer Files
Function File Listing
Function Files
High-Speed Counter File (HSC)
Real-Time Clock File (RTC)
Channel 0 Communication Status File (CS0)
Channel 1 Communication Status File (CS1)
I/O Module Status File (IOS)
Error Codes
Encapsulation Error Codes
CIP Error Codes
0x0001 Extended Error Codes
0x001F Extended Error Codes
0x00FF Extended Error Codes
Event Log Messages
Event Log Messages
Appendices
Appendix A — Channel Properties
Appendix B — Device Properties
Appendix C — Tag Properties
Logix Device IDs
1761-NET-ENI
DataHighwayPlus (TM) Gateway
ControlNet Gateway
EtherNet/IP Gateway Setup
Serial Gateway Setup
MicroLogix 1100 Setup
Communications Routing
Connection Path Specification
Routing Examples
Choosing a Protocol Mode
Detecting a Change in the Controller Project
SoftLogix 5800 Connection Notes
Allen-Bradley ControlLogix Ethernet for Edge
Overview
Setup
Channel Properties — General
Channel Properties — Ethernet Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — Identification
Operating Mode
Device Properties — Scan Mode
Tag Counts
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Tag Generation
Device Properties — Logix Communications Parameters
Device Properties — Logix Options
Device Properties — Logix Database Settings
Device Properties — ENI DF1/DH+/ControlNet Gateway Communications Parameters
Block Writes
SLC 500 Slot Configuration
SLC 500 Modular I/O Selection Guide
Configuration API ControlLogix Examples
Enumerations
Device Model Enumerations
Configuration API — Slot Configuration
Automatic Tag Database Generation
Tag Hierarchy
Controller-to-Server Name Conversions
Preparing for Automatic Tag Database Generation
Performance Optimizations
Optimizing Communications
Optimizing the Application
Data Types Description
Default Data Type Conditions
Address Descriptions
Logix Addressing
MicroLogix Addressing
SLC 500 Fixed I/O Addressing
SLC 500 Modular I/O Addressing
PLC-5 Series Addressing
Logix Tag-Based Addressing
Logix Tag-Based Addressing
Address Formats
Tag Scope
Internal Tags
Predefined Term Tags
Address Usage
Addressing Atomic Data Types
Addressing Structure Data Types
Addressing STRING Data Type
Ordering of Logix Array Data
Logix Advanced Addressing
Advanced Addressing: BOOL
Advanced Addressing: SINT
Advanced Addressing: INT
Advanced Addressing: DINT
Advanced Addressing: LINT
Advanced Addressing: REAL
Advanced Addressing: USINT
Advanced Addressing: UINT
Advanced Addressing: UDINT
Advanced Addressing: ULINT
Advanced Addressing: LREAL
Advanced Addressing: TIME32
Advanced Addressing: TIME
Advanced Addressing: LTIME
DF1 File Listing
File Listing
Output Files
Input Files
Status Files
Binary Files
Timer Files
Counter Files
Control Files
Integer Files
Float Files
ASCII Files
String Files
BCD Files
Long Files
MicroLogix PID Files
PID Files
MicroLogix Message Files
Message Files
Block Transfer Files
Function File Listing
High-Speed Counter File (HSC)
Real-Time Clock File (RTC)
Channel 0 Communication Status File (CS0)
Channel 1 Communication Status File (CS1)
I/O Module Status File (IOS)
Error Codes
Encapsulation Error Codes
CIP Error Codes
0x0001 Extended Error Codes
0x001F Extended Error Codes
0x00FF Extended Error Codes
Event Log Messages
Event Log Messages
Appendices
Appendix A — Channel Properties
Appendix B — Device Properties
Appendix C — Tag Properties
Logix Device IDs
1761-NET-ENI
DataHighwayPlus (TM) Gateway
ControlNet Gateway
EtherNet/IP Gateway Setup
Serial Gateway Setup
MicroLogix 1100 Setup
Communications Routing
Connection Path Specification
Routing Examples
Choosing a Protocol Mode
Detecting a Change in the Controller Project
SoftLogix 5800 Connection Notes
Allen-Bradley ControlLogix Server
Overview
Setup
Channel Properties — General
Channel Properties — Ethernet Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Channel Properties — EtherNet/IP Module
Device Properties — General
Device Properties — Scan Mode
Device Properties — Tag Generation
Device Properties — Controller Module
Device Properties — Native Tag Database
Tag Hierarchy
Device Properties — Options
ControlLogix Client Device Configuration
Logix Config Object
Logix Config CSV Import
Defining New Logix Addresses
Data Types Description
Address Descriptions
Address Formats
Tag Scope
Advanced Addressing
Error Codes
EtherNet/IP Encapsulation Error Codes
CIP Error Codes
0x01 Extended Error Codes
0xFF Extended Error Codes
Event Log Messages
Event Log Messages
Allen-Bradley DF1
Overview
Cable Connections
Setup
Channel Properties — General
Channel Properties — Serial Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Channel Properties — Communication Serialization
Channel Properties — Link Settings
Half Duplex Client
KF2/KF3 Half Duplex Client
Device Setup
Device Properties — General
Device Properties — Scan Mode
Device Properties — Ethernet Encapsulation
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Protocol Settings
Float Words
Device Properties — Function File Options
Slot Configuration
Modular I/O Selection Guide
Data Types Description
Address Descriptions
File Listing
Output Files
Input Files
Status Files
Binary Files
Timer Files
Counter Files
Control Files
Integer Files
Float Files
ASCII Files
String Files
BCD Files
Long Files
Micrologix PID Files
PLC5 PID Files
Micrologix Message Files
PLC5 Message Files
Block Transfer Files
Function File Listing
High Speed Counter File (HSC)
Real-Time Clock File (RTC)
Channel 0 Communication Status File (CS0)
Channel 1 Communication Status File (CS1)
I/O Module Status File (IOS)
Event Log Messages
Event Log Messages
Error Mask Definitions
Communicating with RSLogix5000 Family Controllers
Allen-Bradley Ethernet Driver
Overview
Setup
Channel Properties — General
Channel Properties — Ethernet Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Channel Properties — Communication Serialization
Device Properties — Identification
Operating Mode
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Communications Parameters
Device Properties — Protocol Parameters
Device Properties — Slot Configuration
Modular I/O Selection Guide
Optimizing Communications
Data Types Description
Address Descriptions
General Addressing
Output Files
Input Files
Status Files
Binary Files
Timer Files
Counter Files
Control Files
Integer Files
Float Files
ASCII Files
String Files
String Length
SLC5/05 Open Addressing
PLC-5 Family Addressing
BCD Files
PID Files
Message Files
Block Transfer Files
Event Log Messages
Event Log Messages
Allen-Bradley Micro800 Ethernet
Overview
Setup
Channel Properties — General
Channel Properties — Ethernet Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Channel Properties — Communication Serialization
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Communications Parameters
Device Properties — Options
Performance Optimizations
Optimizing Communications
Optimizing Your Application
Data Types Description
Address Descriptions
Address Formats
Tag Scope
Address Usage
Addressing Atomic Data Types
Addressing Structured Data Types
Ordering of Array Data
Advanced Addressing
Advanced Use Cases
BOOL
SINT, USINT, and BYTE
INT, UINT, and WORD
DINT, UDINT, and DWORD
LINT, ULINT, and LWORD
REAL
LREAL
SHORT_STRING
Error Codes
Encapsulation Protocol Error Codes
CIP Error Codes
0x0001 Extended Error Codes
0x001F Extended Error Codes
0x00FF Extended Error Codes
Event Log Messages
Event Log Messages
Glossary
Allen-Bradley Micro800 Serial
Overview
Device Setup
Channel Setup
Channel Properties — General
Channel Properties — Serial Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Channel Properties — Communication Serialization
Channel Properties — Ethernet Encapsulation
Channel Properties — Link Settings
Channel Creation Wizard
Device Discovery Procedure
Device Setup
Device Properties — General
Device Properties — Ethernet Encapsulation
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Communications Parameters
Device Properties — Options
Device Creation Wizard
Performance Optimizations
Optimizing Communications
Optimizing Application
Data Types Description
Address Descriptions
Address Formats
Tag Scope
Address Usage
Addressing Atomic Data Types
Addressing Structured Data Types
Addressing STRING Data Type
Ordering of Array Data
Advanced Addressing
Advanced Use Cases
BOOL
SINT, USINT, and BYTE
INT, UINT, and WORD
DINT, UDINT, and DWORD
LINT, ULINT, and LWORD
REAL
LREAL
SHORT_STRING
Error Codes
Encapsulation Protocol Error Codes
CIP Error Codes
0x0001 Extended Error Codes
0x001F Extended Error Codes
0x00FF Extended Error Codes
Event Log Messages
Event Log Messages
Glossary
Allen-Bradley Server Ethernet
Overview
Setup
Channel Properties — General
Channel Properties — Ethernet Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Device Properties — Communication Parameters
Device Properties — Options
Allen-Bradley PLC Client Device Configuration
Data Types Description
Address Descriptions
Event Log Messages
Event Log Messages
Alstom Redundant Ethernet
Overview
Setup
Channel Properties — General
Channel Properties — Write Optimizations
Channel Properties — Advanced
Channel Properties — Network Interface
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Device ID
Device Properties — Blocks
Device Properties — Redundancy Settings
Data Types Description
Address Descriptions
Error Descriptions
Modbus Exception Codes
Address Validation
Address <address> is out of range for the specified device or register
Array size is out of range for address <address>
Array support is not available for the specified address: <address>
Data Type <type> is not valid for device address <address>
Device address <address> contains a syntax error
Device address <address> is not supported by model <model name>
Device address <address> is Read Only
Missing address
Device Status Messages
Device <device name> is not responding
Unable to bind to adapter: <network adapter name>. Connect failed
Unable to create a socket connection for device <device name>
Unable to write to address <address> on device <device>: Device responded with exception code <code>
Device Specific Messages
Bad address in block [x to y] on device <device name>
Bad array spanning [<address> to <address>] on device <device name>
Bad received length [x to y] on device <device name>
Failure to initiate 'winsock.dll' [Error: <winsock error>]
Analog Devices
Overview
Setup
Channel Properties — General
Channel Properties — Serial Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Channel Properties — Driver Setup
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Data Format
Data Types Description
Address Descriptions
6B11 Addresses
6B12 Addresses
6B13 Addresses
6B21 Addresses
6B50 Addresses
Error Descriptions
Address Validation
Address <address> is out of range for the specified device or register.
Data type <type> is not valid for device address <address>.
Device address <address> contains a syntax error.
Device address <address> is not supported by model <model name>.
Device address <address> is read only.
Missing address.
Serial Communications
Communications error on <channel name> [<error mask>].
Error Mask Definitions
COMn does not exist.
COMn is in use by another application.
Error opening COMn.
Unable to set comm parameters on COMn.
Device Status Messages
Device <device name> is not responding.
Unable to write to <address> on device <device name>.
Device Specific Messages
Value out of range writing to address <address> on device <device name>.
Aromat Serial
Overview
Setup
Channel Properties — General
Channel Properties — Serial Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Data Types Description
Address Descriptions
C16 Addressing
C24 Addressing
C40 Addressing
Any FP Model Addressing
Error Descriptions
Address Validation
Address '<address>' is out of range for the specified device or register
Data type '<type>' is not valid for device address '<address>'
Device address '<address>' contains a syntax error
Device address '<address>' is not supported by model '<model name>'
Device address '<address>' is read only
Missing address
Serial Communications
Communications error on '<channel name>' [<error mask>]
COMn does not exist
COMn is in use by another application
Error opening COMn
Unable to set comm properties on COMn
Device Status Messages
Device '<device name> not responding
Unable to write to '<address>' on device '<device name>'
Device Specific Messages
Unable to read block for address type '<mnemonic>', words <start address> - <end address>, on device '<device>'
Help Contents
Overview
Setup
Channel Properties — General
Channel Properties — Ethernet Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Communications Properties
Device Properties — Station Numbers
Device Properties — Request Size
ET-LAN Connection Properties
Multi-Homing
Data Types Description
Address Descriptions
Optimizing Communications
Error Descriptions
Address Validation
Missing address
Device address '<address>' contains a syntax error
Address '<address>' is out of range for the specified device or register
Data Type '<type>' is not valid for device address '<address>'
Device address '<address>' is Read Only.
Array size is out of range for address '<address>'
Array support is not available for the specified address: '<address>'
Device Status Messages
Device '<device name>' is not responding
Unable to write to '<address>' on device '<device name>'
Driver Error Messages
Winsock initialization failed (OS Error = n)
Winsock V1.1 or higher must be installed to use the Aromat Ethernet device driver
Unable to bind IP '<IP in hex>' to port '<port>' - address is in use by another application
Response to <read/write> request to '<tag address>' on device '<device name>' contained error code '<xx>'
Response to <read/write> request to '<tag address>' on device '<device name>' had an unexpected format
Response to <read/write> request to '<tag address>' on device '<device name>' failed BCC check
AutomationDirect DirectNET
Overview
Setup
Channel Properties — General
Channel Properties — Serial Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Tag Generation
Device Properties — Tag Import Settings
Automatic Tag Database Generation
Tag Hierarchy
Import File-To-Server Name Conversions
Importing DirectSoft Elements
Import Preparation: DirectSoft Steps
Import Preparation: OPC Server Steps
Data Types Description
Address Descriptions
DL-05 Addressing
DL-06 Addressing
DL-230 Addressing
DL-240 Addressing
DL-250(-1) Addressing
DL-260 Addressing
DL-330 Addressing
DL-340 Addressing
DL-350 Addressing
DL-430 Addressing
DL-440 Addressing
DL-450 Addressing
Error Descriptions
Address Validation
Missing address
Device address '<address>' contains a syntax error
Address '<address>' is out of range for the specified device or register
Device address '<address>' is not supported by model '<model name>'
Data Type '<type>' is not valid for device address '<address>'
Device address '<address>' is Read Only
Serial Communications
COMn does not exist
Error opening COMn
COMn is in use by another application
Unable to set comm properties on COMn
Communications error on '<channel name>' [<error mask>]
Device Status Messages
Device '<device name> not responding
Unable to write to '<address>' on device '<device name>'
Device Specific Messages
Bad address in block [<start address> to <end address>] on device '<device name>'
Automatic Tag Database Generation Messages
Unable to generate a tag database for device <device name>
Unable to generate a tag database for device <device name>. Reason: Import file is invalid
AutomationDirect EBC
Overview
Setup
Channel Properties — General
Channel Properties — Ethernet Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Tag Generation
Device Properties — Link Configuration
Device Properties — Communication Settings
Optimizing Communications
Data Types Description
Address Descriptions
H2-EBC(-F) Addressing
H4-EBC(-F) Addressing
Terminator I/O Addressing
GS Drive Addressing
I/O Addressing
H2-EBC(-F) I/O Addressing
H4-EBC(-F) I/O Addressing
Terminator I/O I/O Addressing
Serial Port Addressing
H2, H4, Terminator I/O Serial Port Addressing
Serial Port Addresses
Serial Port Configuration
Serial Port Configuration: Baud Rate
Serial Port Configuration: #Data Bits
Serial Port Configuration: Parity
Serial Port Configuration: #Stop Bits
Serial Port Configuration: Mode
Serial Port Configuration: Use RTS Line
Serial Port Configuration: Pre-Transmit Delay
Serial Port Configuration: Post-Transmit Delay
GS Drive Addressing
GS Drive Parameter Addressing
GS Drive Status Addressing
Module Hot Swapping
Error Descriptions
Driver Error Messages
Winsock initialization failed (OS Error = n)
Winsock V1.1 or higher must be installed to use the AutomationDirect EBC device driver
Memory allocation error
Driver Warning Messages
Device '<device name> is not responding
Unable to write to '<address>' on device '<device name>'
Device address '<address>' contains a syntax error
Address '<address>' is out of range for the specified device or register
Device address '<address>' is not supported by model '<model name>'
Device address '<address>' is Read Only
Data type '<type>' is not valid for device address '<address>'
Device <device name> returned an error with value <error value> disabling Link Watchdog. All tags will be invalidated
Device <device name> returned an error with value <error value> enabling Link Watchdog with timeout <timeout>. All tags will be invalidated
Read Errors
Address '<address>' is out of range for device '<device name>'. Tag Deactivated
Base referenced in address '<address>' on device '<device name>' does not exist. Tag Deactivated
Module referenced in address '<address>' on device '<device name>' does not exist. Tag Deactivated
Address type invalid for address '<address>' on device '<device name>'. Tag Deactivated
Device '<device name>' returned an error code with value = '<value>' reading address '<address>'
Device '<device name>' : Base '<base>' : Slot '<slot>' returned an error with value = '<error value>'
Device '<device name>' : Base '<base>' : Slot '<slot>' returned a warning with value = '<warning value>'
Device '<device name>' : Base '<base>' : Slot '<slot>' returned information with value = '<info value>'
Device '<device name>' : Base '<base>' : Slot '<slot>' returned an internal error with value = '<internal value>'
Device '<device name>' : Base '<base>' : Slot '<slot>' returned extended error: Type = '<ext err type>', Data = '<error bytes>
Frame received from device '<device name>' contains errors
Frame received from device '<device name>' contains errors. Verify its IP address
Format version of frame received from device '<device name>' is not supported. Tag Deactivated
Model selected for device '<device name>' does not match the actual device model. Verify its IP address
Device '<device name>' block request [<start> to <end>] responded with exception <code>
Bad received length [<start> to <end>] on device '<device name>'
Write Errors
Write rejected. Address '<address>' is out of range for device '<device name>'
Write rejected. Base referenced in address '<address>' on device '<device name>' does not exist
Write rejected. Module referenced in address '<address>' on device '<device name>' does not exist
Write rejected. Invalid address type for address '<address>' on device '<device name>'
Write to address '<address>' failed. Device '<device name>' returned an undefined status code with value = '<value>'
Write to address '<address>' failed. Device '<device name>' : Base '<base>' : Slot '<slot>' returned an error with value..
Write to address '<address>' failed. Device '<device name>' : Base '<base>' : Slot '<slot>' returned a warning with value..
Write to address '<address>' failed. Device '<device name>' : Base '<base>' : Slot '<slot>' returned information with value..
Write to address '<address>' failed. Device '<device name>' : Base '<base>' : Slot '<slot>' returned information with value..
Write to address '<address>' failed. Device '<device name>' : Base '<base>' : Slot '<slot>' returned an internal error with..
Write to address '<address>' failed. Device '<device name>' : Base '<base>' : Slot '<slot>' returned extended error: Type..
Write to address '<address>' failed. Frame received from device '<device name>' contains errors
Write to address '<address>' failed. Frame received from device '<device name>' contains errors. Verify its IP address
Write to address '<address>' failed. Format version of frame received from device '<device name>' is not supported
Write to address '<address>' failed. Model selected for device '<device name>' does not match the actual device model..
Unable to write to address <address>. Device '<device name>' responded with exception <code>
EBC Error Codes
EBC Error Codes
Application Notes
Application Notes: T1F-14THM
Application Notes: D4-HSC
AutomationDirect ECOM
Overview
Setup
Channel Properties — General
Channel Properties — Ethernet Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Tag Generation
Device Properties — Communication Parameters
Device Properties — Tag Import Settings
Automatic Tag Database Generation
Tag Hierarchy
Import File-To-Server Name Conversions
Importing DirectSoft Elements
Importing DirectSoft Elements
Import Preparation: DirectSoft Steps
Import Preparation: OPC Server Steps
Optimizing Your AutomationDirect ECOM Communications
Data Types Description
Address Descriptions
DL-05 Addressing
DL-06 Addressing
DL-240 Addressing
DL-250(-1) Addressing
DL-260 Addressing
DL-430 Addressing
DL-440 Addressing
DL-450 Addressing
Error Descriptions
Address Validation
Missing address
Device address '<address>' contains a syntax error
Address '<address>' is out of range for the specified device or register
Device address '<address>' is not supported by model '<model name>'
Data Type '<type>' is not valid for device address '<address>'
Device address '<address>' is Read Only
Device Status Messages
Device '<device name> not responding
Unable to write to '<address>' on device '<device name>'
Device Specific Messages
Winsock initialization failed (OS Error = n)
Winsock V1.1 or higher must be installed to use the AutomationDirect ECOM device driver
Bad address in block [<start address> to <end address>] on device '<device name>'
Automatic Tag Database Generation Messages
Unable to generate a tag database for device <device name>. Reason: Low memory resources
Unable to generate a tag database for device <device name>. Reason: Import file is invalid
AutomationDirect K Sequence
Overview
Setup
Channel Properties — General
Channel Properties — Serial Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Tag Generation
Device Properties — Tag Import Settings
Automatic Tag Database Generation
Tag Hierarchy
Data Types Description
Address Descriptions
DL-05 Addressing
DL-06 Addressing
DL-105 Addressing
DL-230 Addressing
DL-240 Addressing
DL-250(-1) Addressing
DL-260 Addressing
DL-350 Addressing
DL-430 Addressing
DL-440 Addressing
DL-450 Addressing
SG Series Addressing
SL Series Addressing
Error Descriptions
Address Validation
Missing address
Device address '<address>' contains a syntax error
Address '<address>' is out of range for the specified device or register
Device address '<address>' is not supported by model '<model name>'
Data Type '<type>' is not valid for device address '<address>'
Device address '<address>' is read only
Serial Communications
COMn does not exist
Error opening COMn
COMn is in use by another application
Unable to set comm properties on COMn
Communications error on '<channel name>' [<error mask>]
Device Status Messages
Device '<device name>' is not responding
Unable to write to '<address>' on device '<device name>'
Device Specific Messages
Bad address in block [<start address> to <end address>] on device '<device name>'
Automatic Tag Database Generation Messages
Unable to generate a tag database for device <device name>. Reason: Low memory resources
Unable to generate a tag database for device <device name>. Reason: Import file is invalid
Import File-To-Server Name Conversions
Importing DirectSoft Elements
Import File-To-Server Name Conversions
Import Preparation: DirectSoft Steps
Import Preparation: OPC Server Steps
AutomationDirect Productivity Series Ethernet
Overview
Setup
Channel Properties — General
Channel Properties — Ethernet Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Tag Generation
Device Properties — Communication
Data Handling
Device Properties — Tag Import File Path
Automatic Tag Database Generation
Optimizing AutomationDirect Productivity Series Ethernet Communications
Data Types Description
Address Descriptions
Ordering of Array Data
Address Formats
Error Descriptions
Automatic Tag Database Generation Error Messages
Tag name <tag name> encountered validation error and will not be imported.
Unable to generate a tag database for device <device name>. Reason: Auto tag generation cancelled.
Unable to generate a tag database for device <device name>. Reason: Import file is invalid or corrupt.
Unable to generate a tag database for device <device name>. Reason: Import file not found.
Unable to generate a tag database for device <device name>. Reason: Low memory resources.
Driver Specific Messages
Unable to bind to adapter:<network adapter>. Connect failed. Winsock Err# <error number>.
Winsock initialization failed (OS Error = <OS error code>).
Winsock shut down failed (OS Error = <OS error code>).
Winsock V1.1 or higher must be installed to use the Productivity Series Ethernet device driver.
Read Errors
Cannot read <tag count> items starting at tag <tag address>: address does not exist in device <device name>.
Cannot read <tag count> items starting at tag <tag address>: device <device name> returned error code <error code>.
Cannot read <tag count> items starting at tag <tag address>: error receiving response frame from device <device name>.
Cannot read <tag count> items starting at tag <tag address>: System ID <System ID> does not exist in device <device name>.
Cannot read <tag count> items starting at tag <tag address>: value is invalid for data type <data type> in device <device name>.
Cannot read tag <tag address>: address does not exist in device <device name>.
Cannot read tag <tag address>: device <device name> returned with error code <error code>.
Cannot read tag <tag address>: error receiving response frame from device <device name>.
Cannot read tag <tag address>: System ID <System ID> does not exist in device <device name>.
Cannot read tag <tag address>: value is invalid for data type <data type> in device <device name>.
Write Errors
Cannot write to tag <tag address>: address does not exist in device <device name>.
Cannot write to tag <tag address>: device <device name> returned with error code <error code>.
Cannot write to tag <tag address>: error receiving response frame from device <device name>.
Cannot write to tag <tag address>: System ID <System ID> does not exist in device <device name>.
Cannot write to tag <tag address>: value is invalid for data type <data type> in device <device name>.
Modbus Exception Codes
Appendix: Exporting a CSV File from Productivity Suite
B-C Drivers
BACnet/IP
Overview
Setup
Channel Properties — General
Channel Properties — Ethernet Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Channel Properties — Protocol Settings
Device Discovery Procedure
Device Discovery
Device Properties — Identification
Operating Mode
Device Properties — Scan Mode
Device Properties — Device Timing
Device Properties — Auto-Demotion
Device Properties — Tag Generation
Device Properties — Protocol Settings
APDU
Command Settings
COV
COV Notifications
COV Settings
Event Notifications
Object Instances
Event-Related Properties
Supported Object Types for Event Notifications
Device Properties — Tag Import
Device Properties — Discovery
Supported Objects and Services
Optimizing BACnet/IP Communications
Configuring Multiple Channels
Data Types Description
Enumerated Property Values
Address Descriptions
Addressing Examples
BACnet/IP Objects
Accumulator
Analog Input
Analog Output
Analog Value
Averaging
Binary Input
Binary Output
Binary Value
Calendar
Command
Device
Event Enrollment
File
Group
Life Safety Point
Life Safety Zone
Loop
Multi-State Input
Multi-State Output
Multi-State Value
Notification Class
Program
Schedule
Trend Log
String Formats
VBA Scripts
VBA Scripts for String Parsing and Construction
VBA Scripts Usage Example
Error Descriptions
Cancellation Reasons
Reject Reasons
Error Classes and Codes
Event Log Messages
Event Log Messages
PIC Statement
Beckhoff TwinCAT
Overview
External Dependencies
Setup
Channel Properties — General
Channel Properties — Ethernet Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Tag Generation
Device Properties — Communications Parameters
Device Properties — Options
Device Properties — Symbolic Settings
Automatic Tag Database Generation
Optimizing Performance
Data Type Descriptions
Address Descriptions
Symbolic Tag Based Addressing
Tag Scope
Addressing Atomic Data Types
Error Descriptions
Error Codes
Address Validation
Address <address> is out of range for the specified device or register.
Array size is out of range for address <address>.
Data type <type> is not valid for device address <address>.
Device Address ‘<address>’ contains a syntax error.
Automatic Tag Database Generation Error Messages
Unable to generate a tag database for device <device name>. Reason: Beckhoff TwinCAT ADS DLL necessary for import is not loaded.
Unable to generate a tag database for device <device name>. Reason: Device is not responding.
Unable to generate a tag database for device <device name>. Reason: Device returned error code <#>.
Unable to generate a tag database for device <device name>. Reason: Memory allocation error.
Driver Error Messages
Unable to import from Beckhoff TwinCAT ADS Communication driver.
Unable to load Beckhoff TwinCAT ADS Communication driver.
Unable to open a communication port on the ADS router.
Device Status Error Messages
Device <Device name> is not responding.
Monitoring the global variable <tag address> on device <device name> to update symbol information when a change is detected.
Unable to gather runtime information for device <device name>. Reason: <reason>.
Unable to perform Beckhoff compatibility on device <device name> due to memory allocation error.
Unable to synchronize with configuration file <file name> on device <device name> due to memory allocation error.
Unable to read tag <tag address> on device <device name>. Requesting symbol information for each transaction.
Read Error Messages
Unable to read tag <address> on device <device name>. Actual data type is not compatible with tag of type <data type>.
Unable to read tag <address> on device <device name>. Address bounds exceeded.
Unable to read tag <address> on device <device name>. Beckhoff TwinCAT ADS DLL necessary for runtime is not loaded.
Unable to read tag <address> on device <device name>. Error Code <#>.
Unable to read tag <address> on device <device name>. Memory allocation error.
Unable to read tag <address> on device <device name>. Runtime file is not valid.
Unable to read tag <address> on device <device name>. Symbol not found in file.
Unable to read tag <address> on device <device name>. Tag data size of <size> bytes(s) exceeds actual data size of <size> byte(s).
Unable to read tag <address> on device <device name>. Tag does not meet filtering requirements.
Write Error Messages
Unable to write to tag <address> on device <device name>. Actual data type is not compatible with tag of type <data type>.
Unable to write to tag <address> on device <device name>. Address bounds exceeded.
Unable to write to tag <address> on device <device name>. Beckhoff TwinCAT ADS DLL necessary for runtime is not loaded.
Unable to write to tag <address> on device <device name>. Error Code <#>.
Unable to write to tag <address> on device <device name>. Memory allocation error.
Unable to write to tag <address> on device <device name>. Runtime file is not valid.
Unable to write to tag <address> on device <device name>. Symbol not found in file.
Unable to write to tag <address> on device <device name>. Tag access is Read Only
Unable to write to tag <address> on device <device name>. Tag data size of <size> bytes(s) exceeds actual data size of <size> byte(s).
Unable to write to tag <address> on device <device name>. Tag does not meet filtering requirements.
Technical Notes
TwinCAT Memory Warning.
TwinCAT Time Slice Notes
Appendix — SYSTEMINFO Global Variables in a TwinCAT PLC Project
Appendix — TwinCat 3 AMS Route Configuration
Bristol/IP
Overview
BSAP Networks
Channel Setup
Channel Properties — General
Channel Properties — Ethernet Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Channel Properties — Communication Serialization
Channel Properties — Local Port
Device Setup
Device Properties — General
Device Properties — Scan Mode
Device Properties — Auto-Demotion
Device Properties — Tag Generation
Device Properties — Communication
Device Properties — Timing
Device Properties — Tag Import Properties
Optimizing Communications
Data Types Description
Address Descriptions
Error Descriptions
<Operation> on device <device name> signal <signal> caused an overflow. Some data has been lost.
<Operation> on device <device name> signal <signal> failed. The device does not contain this signal.
<Operation> on device <device name> signal <signal> failed. The device requires higher level permissions to perform this operation.
<Operation> on device <device name> signal <signal> failed. The request was malformed or incomplete.
A read by address failed because the MSD version for device <device name> changed. The driver is sending read by name requests to get the updated MSD version from the device.
A write by address failed because the MSD version for device <device name> changed. The driver is sending a write by name request to the device.
Failed to send a request to device <device>. The device is not communicating.
Failed to send a request to device <device>. The packet is malformed or too large.
Failed to stop Winsock communications.
Failure to initiate 'winsock.dll' [Error:<error>].
Invalid BSAP function.
Read failed on device <device> address <address>. The server expects this address to be of type <type>, but it is of type <type> in the device.
The device is not responding.
The response received from device <device> contains an invalid sequence number. Review timing properties.
The response received from device <device> is malformed.
The response received from device <device> is too large (%<count> bytes). The data is lost.
The signal was not found.
The string written to device <device>, address <address> is too long. The max supported string is <count> characters. The write will continue as is, but the device will truncate the value.
Unable to bind to port <port> on Channel <channel>.
Unable to create a socket connection for Channel <channel>.
Unable to generate a tag database for device <device name>. Reason: Import file does not contain any valid signals.
Write to device <device name> signal <signal> failed. The signal's manual inhibit attribute is set to false, not allowing writes.
Write to device <device name> signal <signal> failed. The signal is read only.
Write to device <device name> signal <signal> failed. The write value is invalid. Make sure the value is within the approved BSAP range.
Appendix: Tag Generation
BUSWARE Ethernet
Overview
Setup
Channel Properties — General
Channel Properties — Ethernet Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — TCP/IP
Device Properties — Blocks
Addressing BUSWARE RS-485 Devices over the Ethernet
Optimizing Communications
Data Types Description
Address Descriptions
Error Descriptions
Address Validation
Address '<address>' is out of range for the specified device or register
Array size is out of range for address '<address>'
Array support is not available for the specified address: '<address>'
Data Type '<type>' is not valid for device address '<address>'
Device address '<address>' contains a syntax error
Device address '<address>' is read only
Missing address
Device Status Messages
Device '<device name>' is not responding
Unable to write to '<address>' on device '<device name>'
Driver Error Messages
Winsock initialization failed (OS Error = n)
Winsock V1.1 or higher must be installed to use the BUSWARE Ethernet Driver
Device Specific Messages
Bad address in block [<start address> to <end address>] on device '<device name>'
Block size mismatch reading [<start address> to <end address>] on device '<device name>
Block request [<start address> to <end address>] on device '<device name>.' responded with exception = n
CODESYS
Overview
Setup
Channel Properties — General
Channel Properties — Write Optimizations
Channel Properties — Advanced
Channel Properties — Communication Parameters
Device Discovery Procedure
Device Discovery Settings
Device Properties — General
Device Properties — Scan Mode
Device Properties — Auto-Demotion
Device Properties — Tag Generation
Automatic Tag Database Generation
Device Properties — Communication Parameters
Device Properties — User Credentials
Device Properties — Tag Import Settings
Performance Optimization
Data Types Description
Addressing
Symbolic Tag-Based Addressing
Tag Scope
Tag Addressing
Nested Structures
Arrays
Array Elements
Bit Addressing
Access Privileges
Addressing Atomic Data Types
Event Log Messages
Event Log Messages
Contrex Serial
Overview
Setup
Channel Properties — General
Channel Properties — Serial Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Device Settings
Data Types Description
Address Descriptions
Error Descriptions
Address Validation
Address <address> is out of range for the specified device or register
Data Type <type> is not valid for device address <address>
Device address <address> contains a syntax error
Device address <address> is not supported by model <model name>
Device address <address> is Read Only
Missing address
Serial Communications
Communications error on <channel name> [<error mask>]
COMn does not exist
COMn is in use by another application
Error opening COMn
Unable to set comm parameters on COMn
Device Status Messages
Device <device name> is not responding
Device Specific Messages
Deactivating Tag <address> on device <device name>. Contrex Error (<error code>) <error description>
Unable to write to <address> on device <device name>
Contrex M-Series
Overview
Setup
Channel Properties — General
Channel Properties — Serial Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Device Settings
Data Types Description
Address Descriptions
M-Cut Addressing
M-Drive Addressing
M-Rotary Addressing
M-Shuttle Addressing
M-Track Addressing
M-Traverse Addressing
M-Trim Addressing
ML-Drive Addressing
ML-Trim Addressing
Error Descriptions
Address Validation
Missing address
Device address '<address>' contains a syntax error
Address '<address>' is out of range for the specified device or register
Device address '<address>' is not supported by model '<model name>'
Data Type '<type>' is not valid for device address '<address>'
Device address '<address>' is Read Only
Serial Communications
COMn does not exist
Error opening COMn
COMn is in use by another application
Unable to set comm parameters on COMn
Communications error on '<channel name>' [<error mask>]
Device Status Messages
Device '<device name>' is not responding
Device Specific Messages
Unable to write to '<address>' on device '<device name>.' Contrex Error (<error code>) <error description>
Deactivating Tag '<address>' on device '<device name>.' Contrex Error (<error code>) <error description>
Custom Interface
Overview
Setup
Channel Properties — General
Channel Properties — Write Optimizations
Channel Properties — Advanced
Channel Properties — Channel Configuration
Channel Properties — Support Information
Device Properties — General
Device Properties — Scan Mode
Device Properties — Auto-Demotion
Device Properties — Configuration
Device Properties — Settings
Device Properties — Timing
Data Types Description
Address Descriptions
Automatic Device/Tag Generation
Developer Information
CIDA Overview
CIDA Requirements
Shared Memory Interface
REGISTER Structure
DATA Structure
VALUE Structure
STRINGARRAY Structure
Reference Implementation
Reference Implementation Architecture
CID / CIDA Reference Implementation Demonstration
Channel Diagnostics
Error Descriptions
Cannot open shared memory file associated with configuration <configuration name>.
Unable to read to register <register offset> on device <device name>. Register corrupted.
Unable to read from register <register offset> on device <device name>. Register is not configured for read access.
Unable to read from register <register offset> on device <device name>. CIDA <CIDA name> returned error code <error code>.
Unable to read from register <register offset> on device <device name>. Register value type is not configured for read data.
Unable to write to register <register offset> on device <device name>. Register is not configured for write access.
Unable to write to register <register offset> on device <device name>. Register value type is not configured for write data.
Unable to write to register <register offset> on device <device name>. CIDA <CIDA name> returned error code <error code>.
Unable to write to register <register offset> on device <device name>. Register corrupted.
Cutler-Hammer D50/300
Overview
Setup
Channel Properties — General
Channel Properties — Serial Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Settings
Data Types Description
Address Descriptions
D50 Addressing
D300 Addressing
OEMax Addressing
Error Descriptions
Address Validation Error Messages
Missing address
Device address '<address>' contains a syntax error
Address '<address>' is out of range for the specified device or register
Device address '<address>' is not supported by model '<model name>'
Data Type '<type>' is not valid for device address '<address>'
Device address '<address>' is read only
Serial Communications Error Messages
COMn does not exist
Error opening COMn
COMn is in use by another application
Unable to set comm parameters on COMn
Communications error on '<channel name>' [<error mask>]
Device Status Error Messages
Device '<device name> not responding
Unable to write to '<address>' on device '<device name>'
Device Specific Error Messages
Bad address in block [<start address> to <end address>] on device '<device name>'
Cutler-Hammer ELC Ethernet
Overview
Setup
Channel Properties — General
Channel Properties — Ethernet Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Ethernet
Device Properties — Block Sizes
Device Properties — Data Encoding
Optimizing Cutler Hammer ELC Ethernet Communications
Data Types Description
Address Descriptions
Error Descriptions
Address Validation
Missing address
Device address '<address>' contains a syntax error
Address '<address>' is out of range for the specified device or register
Device address '<address>' is not supported by model '<model name>'
Data Type '<type>' is not valid for device address '<address>'
Device address '<address>' is read only
Array size is out of range for address '<address>'
Array support is not available for the specified address: '<address>'
Device Status Messages
Device '<device name>' is not responding
Unable to write to '<address>' on device '<device name>'
Unable to write to address '<address>' on device '<device>': Device responded with exception code '<code>'
Device Specific Messages
Failure to initiate 'winsock.dll' (Error: <error code>)
Unable to create a socket connection for device '<device>'
Bad array spanning [<start address> to <end address>] on device '<device>'.
Bad address in block [<start address> to <end address>] on device '<device>'
Device '<device>' block request [<start address> to <end address>] responded with exception <code>
Cutler-Hammer ELC Serial
Overview
Setup
Channel Properties — General
Channel Properties — Serial Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Channel Properties — Driver Setup
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Block Sizes
Device Properties — Data Encoding
Data Types Description
Address Descriptions
Error Descriptions
Address Validation
Missing address
Device address '<address>' contains a syntax error
Address '<address>' is out of range for the specified device or register
Device address '<address>' is not supported by model '<model name>.'
Data Type '<type>' is not valid for device address '<address>'
Device address '<address>' is Read Only
Array size is out of range for address '<address>'
Array support is not available for the specified address: '<address>'
Serial Communications
COMn does not exist
Error opening COMn.
COMn is in use by another application
Unable to set comm parameters on COMn
Communications error on '<channel name>' [<error mask>]
Device Status Messages
Device '<device name>' is not responding
Unable to write to '<address>' on device '<device name>'
Unable to write to address '<address>' on device '<device>': Device responded with exception code '<code>'
Device Specific Messages
Bad address in block [<start address> to <end address>] on device '<device name>'
Bad array spanning ['<address>' to '<address>'] on device '<device name>'
D-F Drivers
Dataforth isoLynx
Overview
Setup
Channel Properties — General
Channel Properties — Write Optimizations
Channel Properties — Advanced
Channel Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Tag Generation
Device Properties — Ethernet
Automatic Tag Database Generation
Data Types Description
Address Descriptions
Error Descriptions
Dataforth Data Acquisition Library Error Code Descriptions
Address Validation
Missing address
Device address '<address>' contains a syntax error
Address '<address>' is out of range for the specified device or register
Data Type '<type>' is not valid for device address '<address>'
Device address '<address>' is Read Only
Device Status Messages
Device '<Device name>' is not responding
Unable to write to '<address>' on device '<device name>.'
Driver Error Messages
Device '<device name>' responded with error '<Error Code>' (Tag '<address>')
Device '<device name>' responded with error '<Error Code>' (Tag '<address>') during Connect
Automatic Tag Database Generation Messages
Unable to Connect to Device or IO Inquire error during tag Database Creation
DDE Client
Overview
Setup
Channel Properties — General
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Device Properties — DDE Server Communications
ReinitializeDDE Tag
Data Types Description
Address Descriptions
Error Descriptions
Address Validation
Address <address> is out of range for the specified device or register.
Array support is not available for the specified address: <address>.
Data Type <type> is not valid for device address <address>.
Device address <address> contains a syntax error.
Device address <address> is not supported by model <model name>.
Device address <address> is read only.
Missing address.
Device Status Messages
Device <device name> is not responding.
Unable to write to <address> on device <device name>. Error code <error code>.
DDE Client Driver Specific Messages
DDE data error on link <server name>, <topic name>, <item name> detected.
DDEML failed to initialize.
DDEML reports low memory error.
Failed to connect server <server name> topic <topic name>.
Failed to establish hot link to <server name>, <topic name>, <item name>.
Reinitialization failed.
Server <server name> topic <topic name> disconnected
DNP Client Ethernet
Setup
Channel Properties — General
Channel Properties — Ethernet Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Channel Properties — Communication Serialization
Channel Properties — Communications
Channel Properties — Timing
Timing and Other Considerations
Device Properties — General
Device Properties — Scan Mode
Device Properties — Tag Generation
Automatic Tag Generation Hints
Device Properties — Auto-Demotion
Device Properties — Communications
Device Properties — Polling
Device Properties — Unsolicited
Device Properties — Event Playback
Device Properties — Tag Import
Device Properties — Authentication
Device Properties — Update Key Authentication
Device Properties — File Control
Device Properties — Advanced
Data Types Description
Address Descriptions
Object Group 0 - Device Attributes
Object Group 1- Binary Inputs
Object Group 3 - Double Bit Inputs
Object Group 10 - Binary Outputs
Object Group 12 - Binary Output Commands
Object Group 20 - Counters
Object Group 21 - Frozen Counters
Object Group 30 - Analog Inputs
Object Group 34 - Analog Inputs Deadband
Object Group 40 - Analog Outputs
Object Group 41 - Analog Output Commands
Object Group 50 - Time and Date
Object Group 60 - Class Poll Data Request
Object Group 70 - File Identifiers
Object Group 80 - Internal Indications
Object Group 87 - Data Sets
Object Group 110 - Octet String Object
Object Group 120 - Authentication Object
Other Other Object Groups
DNP Tags
Internal Tags
Special Tags
Device Profile
Device Properties — Identification
Link Layer
Application Layer
Clients (Masters) Only
Security Parameters
Implementation Tables
Error Descriptions
Address Validation
Address <address> is not valid on device <channel> <device>.
Address <address> is out of range for the specified device or register.
Data type <type> is not valid for device address <address>.
Device address <address> contains a syntax error.
Device address <address> is read only.
Authentication Error Messages
Secure authentication failure on device <channel.device>. Device does not support the function code (IIN2.0).
Secure authentication failure on device <channel.device>. Key Status Request communications failure. Session keys are not valid.
Secure authentication failure on device <channel.device>. Key Status Request non-authentic. Session Keys are not valid.
Secure authentication failure on device <channel.device>. Aggressive Mode Response indicates improper authentication.
Secure authentication failure on device <channel.device>. Challenge Reply indicates improper authentication.
Secure authentication failure on device <channel.device>. User= <User Number>, AssocID= <Association ID>, Sequence= <Sequence Number>. RX Error Code= <error code>-<error description>.
Secure authentication failure on device <channel.device>. User= <User Number>, AssocID= <Association ID>, Sequence= <Sequence Number>. TX Error Code= <error code>-<error description>.
Secure authentication failure on device <channel.device>. Authentication reply timed out.
Secure authentication failure on device <channel.device>. Authorization failure.
Secure authentication failure on device <channel.device>. Session key change failed.
Secure authentication failure on device <channel.device>. Update key change failed.
Secure authentication failure on device <device>. Key Status Request response status code: <status code>.
Automatic Tag Database Generation Error Messages
Unable to add data set <data set index> on device <device name>. Data set has <number of elements> elements. The maximum number of elements allowed is <max elements>.
Unable to generate a tag database for device <device>. Channel is not open.
Unable to generate a tag database for device <device>. Session is not open.
Unable to generate a tag database for device <driver>. The device is not responding.
Unable to read device attribute set <set number>. No tags added on device <device>.
Device Status Messages
<item description> on device <device> has been auto-demoted
<item description> on device <device> has been auto-promoted to determine if it can be completed
Added <tag count> data set tag(s).
Data Set write of value <value to be written> pending on tag address <address> on device <device>.
Device <device> does not support the LAN Time Sync Style Record Current Time Function Code 24.
Device <device> does not support the LAN Time Sync Style write to object group 50, variation 3.
Device <device> indicated an event buffer overflow (IIN 2.3).
Device <device> indicated it restarted (IIN 1.7).
Device <device> initialization completed.
Device <device> requested time synchronization (IIN 1.4).
Device <device> is restarting.
Device <device name> is not responding.
Failed to resolve Destination Host <host name> on channel <channel name>.
The Keep-Alive Interval with UDP Protocol on device <device> was overridden.
Reached max. events per point for object group <object group> point <data index> on device <device>.
Request failed on device <device>. Device does not support the function code (IIN2.0).
Request to enable unsolicited messaging failed on device <device>.
Unable to bind to local address (IP: xxx.xxx.xxx.xxx, Source Port: ).
Unable to read point(s) <OBJ.VAR.IDX> on device <device>. Failed to initialize communication stack.
Unable to read point(s) <OBJ.VAR.IDX> on device <device>. Internal Error occurred.
Unable to read point(s) <OBJ.VAR.IDX – OBJ.VAR.IDX> on device <device>. Failed to initialize communication stack.
Unable to read point(s) <OBJ.VAR.IDX – OBJ.VAR.IDX> on device <device>. Internal error occurred.
Unable to read tag <tag address> on device <device>. Device indicates one or more exception conditions (DNP flags byte=<hexadecimal byte> - <DNP flag exception list).
Unable to receive response from device <device> within timeout. Either the request or response could not be completed or the response is invalid.
Unable to write to address <address> on device <device>. Failed to initialize communication stack.
Unable to write to address <address> on device <device>. Internal error occurred.
Write complete to data set <index> on device <device>.
Driver Error Messages
Winsock initialization failed (OS Error = n).
Winsock shutdown failed.
Winsock V1.1 or higher must be installed to use the driver.
DNP Specific Error Messages
Read Errors
The returned value for tag address <tag address> in device <device name> has a length of zero. The tag value cannot be set.
The returned value of <date returned value> for tag address <address> in device <device> is invalid for the <data type> tag data type.
The returned value of <returned numeric value> for tag address <address> in device <device> is invalid for the <data type> tag data type.
The returned value of <returned numeric value> for tag address <address> in device <device> is out of range for the <data type> tag data type.
The returned value of <returned string value> for tag address <address> in device <device> is invalid for the <data type> tag data type.
Unable to read point(s) <OBJ.VAR.IDX> on device <device>. An abnormal condition exists in the device (IIN1.6).
Unable to read point(s) <OBJ.VAR.IDX> on device <device>. Device detected corrupt configuration (IIN2.5).
Unable to read point(s) <OBJ.VAR.IDX> on device <device>. Device does not support a point in the range or other parameter error (IIN2.2).
Unable to read point(s) <OBJ.VAR.IDX> on device <device>. Device does not support requested operation for objects in the request (IIN2.1).
Unable to read point(s) <OBJ.VAR.IDX> on device <device>. Device does not support the function code (IIN2.0).
Unable to read point(s) <OBJ.VAR.IDX> on device <device>. Device reports that some output points are in local mode (IIN1.5).
Unable to read point(s) <OBJ.VAR.IDX> on device <device>. Device reports that the operation is already executing (IIN2.4).
Unable to read point(s) <OBJ.VAR.IDX> on device <device>. Session shutting down or duplicate request.
Unable to read point(s) <OBJ.VAR.IDX> on device <device>. Unable to receive response from device <device> within timeout. Either the request or response could not be completed or the response is invalid.
Unable to read point(s) <OBJ.VAR.IDX> on device <device>. Unrecognized object returned in response.
Unable to read point(s) <OBJ.VAR.IDX – OBJ.VAR.IDX> on device <device>. An abnormal condition exists in the device (IIN1.6).
Unable to read point(s) <OBJ.VAR.IDX – OBJ.VAR.IDX> on device <device>. Device detected corrupt configuration (IIN2.5).
Unable to read point(s) <OBJ.VAR.IDX – OBJ.VAR.IDX> on device <device>. Device does not support a point in the range or other parameter error (IIN2.2).
Unable to read point(s) <OBJ.VAR.IDX – OBJ.VAR.IDX> on device <device>. Device does not support requested operation for objects in the request (IIN2.1).
Unable to read point(s) <OBJ.VAR.IDX – OBJ.VAR.IDX> on device <device>. Device does not support the function code (IIN2.0).
Unable to read point(s) <OBJ.VAR.IDX – OBJ.VAR.IDX> on device <device>. Device reports that some output points are in local mode (IIN1.5).
Unable to read point(s) <OBJ.VAR.IDX – OBJ.VAR.IDX> on device <device>. Device reports that the operation is already executing (IIN2.4).
Unable to read point(s) <OBJ.VAR.IDX – OBJ.VAR.IDX> on device <device>. Session shutting down or duplicate request.
Unable to read point(s) <OBJ.VAR.IDX - OBJ.VAR.IDX> on device <device>. Unable to receive response from device <device> within timeout. Either the request or response could not be completed or the response is invalid.
Unable to read point(s) <OBJ.VAR.IDX – OBJ.VAR.IDX> on device <device>. Unrecognized object returned in response.
Unable to read set <set index> of object group <object group> on device <device>. An abnormal condition exists in the device (IIN1.6).
Unable to read set <set index> of object group <object group> on device <device>. Device detected corrupt configuration (IIN2.5).
Unable to read set <set index> of object group <object group> on device <device>. Device does not support a point in the range or other parameter error (IIN2.2).
Unable to read set <set index> of object group <object group> on device <device>. Device does not support requested operation for objects in the request (IIN2.1).
Unable to read set <set index> of object group <object group> on device <device>. Device does not support the function code (IIN2.0).
Unable to read set <set index> of object group <object group> on device <device>. Device reports that some output points are in local mode (IIN1.5).
Unable to read set <set index> of object group <object group> on device <device>. Device reports that the operation is already executing (IIN2.4).
Unable to read set <set index> of object group <object group> on device <device>. Session shutting down or duplicate request.
Unable to read set <set index> of object group <object group> on device <device>. Unrecognized object returned in Response.
Unable to read tag address <address> on device <device>. Element index <variation> is not defined in data set <index>.
Unable to read tag address <address> on device <device>. No definition for data set <index>.
Unable to read tag address <address> on device <device>. Response missing data.
Write Errors
Unable to write to address <address> on device <device>. Activate configuration-related status code <status code> - <description>.
Unable to write to address <address> on device <device>. An abnormal condition exists in the device (IIN1.6).
Unable to write to address <address> on device <device>. Channel response timeout must be between <min channel response timeout> and <max channel response timeout>.
Unable to write to address <address> on device <device>. Control-related status code <status code>.
Unable to write to address <address> on device <device>. Destination <eestination host>:<destination port> already in use on channel <channel>.
Unable to write to address <address> on device <device>. Destination Port must be between <min. source port> and <max. source port>.
Unable to write to address <address> on device <device>. Device detected corrupt configuration (IIN2.5).
Unable to write to address <address> on device <device>. Device does not support a point in the range or other parameter error (IIN2.2).
Unable to write to address <address> on device <device>. Device does not support requested operation for objects in the request (IIN2.1).
Unable to write to address <address> on device <device>. Device does not support the function code (IIN2.0).
Unable to write to address <address> on device <device>. Device reports that some output points are in local mode (IIN1.5).
Unable to write to address <address> on device <device>. Device reports that the operation is already executing (IIN2.4).
Unable to write to address <address> on device <device>. Device Request Timeout must be between <min. value> and <max value>.
Unable to write to address <address> on device <device>. Element index <variation> is not defined in data set <index>.
Unable to write to address <address> on device <device>. Event poll interval must be between <min. value> and <max. value>.
Unable to write to address <address> on device <device>. File name writes have been disabled.
Unable to write to address <address> on device <device>. Integrity poll interval must be between <min. value> and <max value>.
Unable to write to address <address> on device <device>. DNP client address <DNP address> already in use as DNP server address on device <device>.
Unable to write to address <address> on device <device>. DNP client address must be between <min DNP address> and <max DNP address>.
Unable to write to address <address> on device <device>. DNP client and DNP server address cannot be the same.
Unable to write to address <address> on device <device>. No definition for Data Set <index>.
Unable to write to address <address> on device <device>. Protocol must be between <min. protocol> and <max. protocol>.
Unable to write to address <address> on device <device>. Select Operate response invalid.
Unable to write to address <address> on device <device>. Session shutting down or duplicate request.
Unable to write to address <address> on device <device>. DNP server address <DNP address> already in use on device <device>.
Unable to write to address <address> on device <device>. DNP server address must be between <min. DNP address> and <max. DNP address>.
Unable to write to address <address> on device <device>. Source p[ort must be between <min source port> and <max source port>.
Unable to write to address <address> on device <device>. Tag <data type> data type is incompatible with the Data Set element <data type> data type.
Unable to write to address <address> on device <device>. Unable to receive response from device <device> within timeout. Either the request or response could not be completed or the response is invalid.
Unable to write to address <address> on device <device>. Unrecognized object returned in response.
Unable to write to address <address> on device <device>. Unsupported Operation Type.
Unable to write to address <address> on device <device>. Unsupported Trip-Close Code.
Unable to write to address <address> on device <device>. Write value specified is invalid or incomplete.
File Control Error Messages
File Transfer failure on device <device> for file index <index>. Device returned File-Related Status Code <status code> - <description>.
File Transfer failure on device <device> for file index <index>. File size of <size> kilobytes is greater than maximum file size of <maximum size> kilobytes.
File Transfer failure on device <device> for file index <index>. File transfer stopped by user.
File Transfer failure on device <device> for file index <index>. File transfer stopped due to communications issue.
File Transfer failure on device <device> for file index <index>. Local file <file name> is empty.
File Transfer failure on device <device> for file index <index>. Local file open failure. <local file open failure>.
File Transfer failure on device <device> for file index <index>. Session shutting down or duplicate request.
Invalid local file for file index 70.<file index>, general error
Invalid Local File for File Index 70.<file index>, verify the specified path is write-enabled
Invalid Local File path for File Index 70.<file index>
Invalid Local File syntax for File Index 70.<file index>
DNP Client Serial
Overview
Setup
Channel Properties — General
Channel Properties — Serial Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Channel Properties — Communication Serialization
Channel Properties — Timing
Timing and Other Considerations
Device Properties — General
Device Properties — Scan Mode
Device Properties — Tag Generation
Automatic Tag Generation Hints
Device Properties — Auto-Demotion
Device Properties — Communications
Device Properties — Polling
Device Properties — Unsolicited
Device Properties — Event Playback
Device Properties — Tag Import
Device Properties — Authentication
Device Properties — Update Key Authentication
Device Properties — File Control
Device Properties — Advanced
Data Types Description
Address Descriptions
Object Group 0 - Device Attributes
Object Group 1 - Binary Inputs
Object Group 3 - Double-Bit Inputs
Object Group 10 - Binary Outputs
Object Group 12 - Binary Output Commands
Object Group 20 - Counters
Object Group 21 - Frozen Counters
Object Group 30 - Analog Inputs
Object Group 34 - Analog Inputs Deadband
Object Group 40 - Analog Outputs
Object Group 41 - Analog Output Commands
Object Group 50 - Time and Date
Object Group 60 - Class Poll Data Request
Object Group 70 - File Identifiers
Object Group 80 - Internal Indications
Object Group 87 - Data Sets
Object Group 110 - Octet String Object
Object Group 120 - Authentication Object
Other Object Groups
DNP Tags
Internal Tags
Special Tags
Device Profile
Device Identification
Link Layer
Application Layer
Clients (Masters) Only
Security Parameters
Implementation Tables
Error Descriptions
Address Validation
Address <address> is not valid on device <channel> <device>.
Address <address> is out of range for the specified device or register.
Data type <type> is not valid for device address <address>.
Device address <address> contains a syntax error.
Device address <address> is read only.
Authentication Error Messages
Secure authentication failure on device <channel.device>. Device does not support the function code (IIN2.0).
Secure authentication failure on device <channel.device>. Authentication reply timed out.
Secure authentication failure on device <channel.device>. Authorization failure.
Secure authentication failure on device <channel.device>. Session key change failed.
Secure authentication failure on device <channel.device>. Update key change failed.
Secure authentication failure on device <channel.device>. Key Status Request communications failure. Session keys are not valid.
Secure authentication failure on device <channel.device>. Key Status Request non-authentic. Session keys are not valid.
Secure authentication failure on device <channel.device>. Aggressive Mode response indicates improper authentication.
Secure authentication failure on device <channel.device>. Challenge Reply indicates improper authentication .
Secure authentication failure on device <channel.device>. User= <user number>, AssocID= <Association ID>, Sequence= <sequence number>. RX Error Code= <error code>-<error description>.
Secure authentication failure on device <channel.device>. User= <user number>, AssocID= <Association ID>, Sequence= <sequence number>. TX Error Code= <error code>-<error description>.
Secure authentication failure on device <device>. Key Status Request response status code: <status code>.
Automatic Tag Database Generation Messages
Unable to add data set <data set index> on device <device name>. Data set has <number of elements> elements. The maximum number of elements allowed is <max. elements>.
Unable to generate a tag database for device <device>. Channel is not open.
Unable to generate a tag database for device <device>. Session is not open.
Unable to generate a tag database for device <device name>. Unable to open communications port.
Unable to generate a tag database for device <driver>. The device is not responding.
Unable to read device attribute set <set number>. No tags added on device <device>.
Device Status Messages
<Item description> on device <device> has been auto-demoted.
<item description> on device <device> has been auto-promoted to determine if it can be completed.
Added <tag count> Data Set tag(s).
Data set write of value <value to be written> pending on tag address <address> on device <device>.
Device <device> does not support the LAN Time Sync Style Record Current Time Function Code 24.
Device <device> does not support the LAN Time Sync Style write to object group 50, variation 3.
Device <device> indicated an event buffer overflow (IIN 2.3).
Device <device> indicated it restarted (IIN 1.7).
Device <device> initialization completed.
Device <device> requested time synchronization (IIN 1.4).
Device <device> restarting
Device <device name> is not responding.
Reached Max. Events Per Point for object group <object group> Point <data index> on device <device>.
Request failed on device <device>. Device does not support the function code (IIN2.0).
Request to enable unsolicited messaging failed on device <device>.
Unable to bind to local address (IP: xxx.xxx.xxx.xxx, Source Port: x).
Unable to read point(s) <OBJ.VAR.IDX> on device <device>. Failed to initialize communication stack.
Unable to read point(s) <OBJ.VAR.IDX> on device <device>. Internal error occurred.
Unable to read point(s) <OBJ.VAR.IDX – OBJ.VAR.IDX> on device <device>. Failed to initialize communication stack.
Unable to read point(s) <OBJ.VAR.IDX – OBJ.VAR.IDX> on device <device>. Internal error occurred.
Unable to read tag <tag address> on device <device>. Device indicates one or more exception conditions (DNP flag byte=<hexadecimal byte> - <DNP flag exception list').
Unable to receive response from device <device> within timeout. Either the request or response could not be completed or the response is invalid.
Unable to write to address <address> on device <device>. Failed to initialize communication stack.
Unable to write to address <address> on device <device>. Internal error occurred.
Write complete to data set <index> on device <device>.
DNP Specific Error Messages
Read Errors
The returned value for tag address <tag address> in device <device name> has a length of zero. The tag value cannot be set.
The returned value of <date returned value> for tag address <address> in device <device> is invalid for the <data type> tag data type.
The returned value of <returned numeric value> for tag address <address> in device <device> is invalid for the <data type> tag data type.
The returned value of <returned numeric value> for tag address <address> in device <device> is out of range for the <data type> tag data type.
The returned value of <returned string value> for tag address <address> in device <device> is invalid for the <data type> tag data type.
Unable to read point(s) <OBJ.VAR.IDX> on device <device>. An abnormal condition exists in the device (IIN1.6).
Unable to read point(s) <OBJ.VAR.IDX> on device <device>. Device detected corrupt configuration (IIN2.5).
Unable to read point(s) <OBJ.VAR.IDX> on device <device>. Device does not support a point in the range or other parameter error (IIN2.2).
Unable to read point(s) <OBJ.VAR.IDX> on device <device>. Device does not support requested operation for objects in the request (IIN2.1).
Unable to read point(s) <OBJ.VAR.IDX> on device <device>. Device does not support the function code (IIN2.0).
Unable to read point(s) <OBJ.VAR.IDX> on device <device>. Device reports that some output points are in local mode (IIN1.5).
Unable to read point(s) <OBJ.VAR.IDX> on device <device>. Device reports that the operation is already executing (IIN2.4).
Unable to read point(s) <OBJ.VAR.IDX> on device <device>. Session shutting down or duplicate request.
Unable to read point(s) <OBJ.VAR.IDX> on device <device>. Unable to receive response from device <device> within timeout. Either the request or response could not be completed or the response is invalid.
Unable to read point(s) <OBJ.VAR.IDX> on device <device>. Unrecognized object returned in response.
Unable to read point(s) <OBJ.VAR.IDX – OBJ.VAR.IDX> on device <device>. An abnormal condition exists in the device (IIN1.6).
Unable to read point(s) <OBJ.VAR.IDX – OBJ.VAR.IDX> on device <device>. Device detected corrupt configuration (IIN2.5).
Unable to read point(s) <OBJ.VAR.IDX – OBJ.VAR.IDX> on device <device>. Device does not support a point in the range or other parameter error (IIN2.2).
Unable to read point(s) <OBJ.VAR.IDX – OBJ.VAR.IDX> on device <device>. Device does not support requested operation for objects in the request (IIN2.1).
Unable to read point(s) <OBJ.VAR.IDX – OBJ.VAR.IDX> on device <device>. Device does not support the function code (IIN2.0).
Unable to read point(s) <OBJ.VAR.IDX – OBJ.VAR.IDX> on device <device>. Device reports that some output points are in local mode (IIN1.5).
Unable to read point(s) <OBJ.VAR.IDX – OBJ.VAR.IDX> on device <device>. Device reports that the operation is already executing (IIN2.4).
Unable to read point(s) <OBJ.VAR.IDX – OBJ.VAR.IDX> on device <device>. Session shutting down or duplicate request.
Unable to read point(s) <OBJ.VAR.IDX - OBJ.VAR.IDX> on device <device>. Unable to receive response from device <device> within timeout. Either the request or response could not be completed or the response is invalid.
Unable to read point(s) <OBJ.VAR.IDX – OBJ.VAR.IDX> on device <device>. Unrecognized object returned in response.
Unable to read set <set index> of object group <object group> on device <device>. An abnormal condition exists in the device (IIN1.6).
Unable to read set <set index> of object group <object group> on device <device>. Device detected corrupt configuration (IIN2.5).
Unable to read set <set index> of object group <object group> on device <device>. Device does not support a point in the range or other parameter error (IIN2.2).
Unable to read set <set index> of object group <object group> on device <device>. Device does not support requested operation for objects in the request (IIN2.1).
Unable to read set <set index> of object group <object group> on device <device>. Device does not support the function code (IIN2.0).
Unable to read set <set index> of object group <object group> on device <device>. Device reports that some output points are in local mode (IIN1.5).
Unable to read set <set index> of object group <object group> on device <device>. Device reports that the operation is already executing (IIN2.4).
Unable to read set <set index> of object group <object group> on device <device>. Session shutting down or duplicate request.
Unable to read set <set index> of object group <object group> on device <device>. Unrecognized object returned in response.
Unable to read tag address <address> on device <device>. Element index <variation> is not defined in data set <index>.
Unable to read tag address <address> on device <device>. No definition for data set <index>.
Unable to read tag address <address> on device <device>. Response missing data.
Write Errors
Unable to write to address <address> on device <device>. Activate Configuration-Related Status Code <status code> - <description>.
Unable to write to address <address> on device <device>. An abnormal condition exists in the device (IIN1.6).
Unable to write to address <address> on device <device>. Channel Response Timeout must be between <min. channel response timeout> and <max. channel response timeout>.
Unable to write to address <address> on device <device>. Control-Related Status Code <status code>.
Unable to write to address <address> on device <device>. Device detected corrupt configuration (IIN2.5).
Unable to write to address <address> on device <device>. Device does not support a point in the range or other parameter error (IIN2.2).
Unable to write to address <address> on device <device>. Device does not support requested operation for objects in the request (IIN2.1).
Unable to write to address <address> on device <device>. Device does not support the function code (IIN2.0).
Unable to write to address <address> on device <device>. Device reports that some output points are in local mode (IIN1.5).
Unable to write to address <address> on device <device>. Device reports that the operation is already executing (IIN2.4).
Unable to write to address <address> on device <device>. Device Request Timeout must be between <min. value> and <max. value>.
Unable to write to address <address> on device <device>. Element index <variation> is not defined in data set <index>.
Unable to write to address <address> on device <device>. Event Poll Interval must be between <min. value> and <max. value>.
Unable to write to address <address> on device <device>. File name writes have been disabled.
Unable to write to address <address> on device <device>. Integrity Poll Interval must be between <min. value> and <max. value>.
Unable to write to address <address> on device <device>. DNP client address <DNP client address> already in use as DNP server address on device <device>.
Unable to write to address <address> on device <device>. DNP client address must be between <min. DNP address> and <max. DNP address>.
Unable to write to address <address> on device <device>. DNP client and DNP server address cannot be the same.
Unable to write to address <address> on device <device>. No definition for data set <index>.
Unable to write to address <address> on device <device>. Select operate response invalid.
Unable to write to address <address> on device <device>. Session shutting down or duplicate request.
Unable to write to address <address> on device <device>. DNP server address <DNP server address> already in use on device <device>.
Unable to write to address <address> on device <device>. DNP server address must be between <min. DNP address> and <max. DNP address>.
Unable to write to address <address> on device <device>. Tag <data type> data type is incompatible with the data set element <data type> data type.
Unable to write to address <address> on device <device>. Unable to receive response from device <device> within timeout. Either the request or response could not be completed or the response is invalid.
Unable to write to address <address> on device <device>. Unrecognized object returned in response.
Unable to write to address <address> on device <device>. Unsupported operation type.
Unable to write to address <address> on device <device>. Unsupported Trip-Close Code.
Unable to write to address <address> on device <device>. Write value specified is invalid or incomplete.
File Control Error Messages
File transfer failure on device <device> for file index <index>. Device returned File-Related Status Code <status code> - <description>.
File transfer failure on device <device> for file index <index>. File size of <size> kilobytes is greater than maximum file size of <maximum size> kilobytes.
File transfer failure on device <device> for file index <index>. File transfer cancellation by user.
File transfer failure on device <device> for file index <index>. File transfer cancelled due to communications issue.
File transfer failure on device <device> for file index <index>. Local file <file name> is empty.
File transfer failure on device <device> for file index <index>. Local file open failure. <local file open failure>.
File transfer failure on device <device> for file index <index>. Session shutting down or duplicate request.
Invalid local file for File Index 70.<file index>, general error.
Invalid local file for File Index 70.<file index>, verify the specified path is write-enabled.
Invalid local file path for File Index 70.<file index>.
Invalid local file syntax for File Index 70.<file index>.
Enron Modbus
Overview
Setup
Channel Properties — General
Channel Properties — Serial Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Channel Properties — Communication Serialization
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Tag Generation
Automatic Tag Database Generation
Device Properties — Time Synchronization
Device Properties — Settings
Device Properties — Block Sizes
Device Properties — Framing
Device Properties — Error Handling
Device Properties — EFM Meters
Configuration Mapping
History Mapping
Alarm Mapping
Event Mapping
EFM Cache
Address Ranges
CSV Import/Export
Data Types Description
Address Descriptions
Error Descriptions
Address Validation
Address <address> is out of range for the specified device or register.
Array size is out of range for address <address>.
Data Type <type> is not valid for device address <address>.
Device address <address> contains a syntax error.
Device Status Messages
Device <device name> is not responding.
Unable to write to <address> on device <device name>.
Enron Modbus Specific Messages
<Device Name> - Failed to read EFM pointer file. <Extended Error>.
<Device name> - Failed to write EFM pointer file. <Extended error>.
Alarm mapping for address <address> is invalid and will be ignored.
Archive address <address> is used in Meter <number> for <archive> archive and in Meter < number> for <archive> archive in device <device name>. Duplicate archive addresses are not allowed.
Bad address in block [<start address> to <end address>] on device <device name>.
Bad array spanning [<address> to <address>] on device <device>.
Block address [<start address> to <end address>] on device <device> responded with exception code <code>.
Config attribute <attribute index> is unknown and will be ignored.
Config mapping for attribute <attribute name> is invalid and will be ignored.
Error parsing alarm/event record. The record size is incorrect.
Error parsing history record. History mapping does not match record read from device, record will not be logged.
Error reading date and time, alarm/event record will not be logged.
Error reading date and time, history record will not be logged.
Failure to load <mapping name> mapping from CSV. The header contains a duplicate field name <name>.
Failure to load <mapping name> mapping from CSV. The header contains an unrecognized field name <name>.
Failure to load <mapping name> mapping from CSV. There is no header in the CSV file.
History attribute <attribute index> is unknown and will be ignored.
History mapping for attribute <attribute name> is invalid and will be ignored.
Meter <number> has an invalid EFM Mapping (<mapping name>). Defaulting the mapping to <mapping name>.
Meter name <name> is used in Meter <number> and in Meter <number> in device <device name>. Duplicate meter names are not allowed.
Serialization of EFM data to temporary file <file name> failed. Reason: <file I/O error>.
The configuration map address <address> for meter <meter name> is beyond the maximum address allowed by the Enron Modbus protocol. This address will be ignored.
The device archive index is larger than the archive size configured in the server. Please reconfigure the device with the correct archive size.
The EFM Meter Daily GC data value <value> in device <device name>’ is not valid. Valid range is 0 or <min> to <max>.
The EFM Meter Event Counter value <value> in device <device name> is not valid. Valid range is 0 or <min> to <max>.
The EFM Meter Hourly GC data value <value> in device <device name> is not valid. Valid range is 0 or <min> to <max>.
The requested record does not exist or is invalid for <archive tag> on <device>. Cancelling the poll. Please verify the archive configuration settings.
Unable to create tag for EFM configuration attribute <attribute> with address <address> on meter <meter name>.
Unable to read <address> from device <device name>. The device is configured for broadcast writes only.
Unable to read block address [<start address> to <end address>] on device <device name>. Unexpected characters in response.
Unable to read from address <address> on device <device>: Device responded with exception code <code>.
Unable to read from address <address> on device <device>. The configured device ID did not match the value retrieved from the device(<deviceID>).
Unable to read from address <address> on device <device name>. Response is not the correct size.
Unable to read from address <address> on device <device name>. Unexpected characters in response.
Unable to read <address> from device <device name>. The device is not responding.
Unable to synchronize time with device <device name>. The device is not responding.
Unable to write to address <address> on device <device>: Device responded with exception code <code>.
Unable to write to address <address> on device <device name>. Unexpected characters in response.
Value for attribute <attribute name> retrieved from Configuration read could not be associated with a valid enumerable value.
Warning loading <mapping name> mapping from CSV. Alarm state for address <address> is invalid. Setting the state to off.
Warning loading <mapping name> mapping from CSV. Alarm type for address <address> is invalid. Setting the type to differential pressure alarm.
Warning loading <mapping name> mapping from CSV. Ignoring alarm with no address.
Warning loading <mapping name> mapping from CSV. Ignoring record with no address.
Warning loading <mapping name> mapping from CSV. No records were imported.
Warning loading <mapping name> mapping from CSV. The attribute <name> is unknown, and will be ignored.
Serial Communications
Communications error on <channel name> [<error mask>].
COMn does not exist.
COMn is in use by another application.
Error opening COMn
Unable to set comm properties on COMn.
Modbus Exception Codes
EUROMAP 63
Overview
Architecture
Setup
Channel Properties — General
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Tag Generation
Automatic Tag Generation
Device Properties — Communications Parameters
Data Exchange Interface
Optimizing Communications
Shared Session Folder
Supported Euromap 63 Request Commands
Data Types Description
Address Descriptions
Event Log Messages
Event Log Messages
Getting Started
Overview
External Dependencies
Install a Focas Library
Additional Software Requirements
Setup
Channel Properties — General
Channel Properties — Ethernet Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Communications Parameters
Device Properties — Unsolicited Transfer Control
Device Properties — Unsolicited Data Areas
Unsolicited Messaging
Optimizing Communications
Data Types Description
Address Descriptions
Series 15i
Series 16i
Series 18i
Series 21i
Power Mate i
Open
CNC Data
System Info Tags
Status Info Tags
Tool Offset
Workpiece Zero Offset
Parameter Read Valuess
Alarm Values
Diagnostic Values
Path Values
Read Axis Data Values
Program Values
Program Name
Read Dynamic2 Data Values
Read Alarm Messages
Read Timer Data Values
Read Program Directory Data
Error Descriptions
Address Validation
Address <address> is out of range for the specified device or register.
Array size is out of range for address <address>.
Array support is not available for the specified address: <address>.
Data Type <type> is not valid for device address <address>.
Device address <address> contains a syntax error.
Device address <address> is read only.
Missing address.
Device Status Messages
Device <device name> is not responding.
Unable to write to <address> on device <device name>.
Driver Error Messages
Could not acquire library handle for device <channel.device>. FWLIB error: <code>.
Could not read one or more vacant macros in range starting at <address> on device <device>.
Could not set request timeout for device <channel.device>. FWLIB error: <code>.
Invalid XML document. Reason: Error loading Unsolicited Data Areas for device <device-name>. End address can not be less than start address for area <area-number>.
Invalid XML document. Reason: Error loading Unsolicited Data Areas for device <device-name>. Invalid area order or duplicate area number.
Invalid XML document. Reason: Error loading Unsolicited Data Areas for device <device-name>. Maximum size of area <area-number> is <size> bytes.
Read error occurred for address starting at <address> on device <channel.device>. FWLIB error: <code>.
Unable to start the Fanuc Focas Data Window Library services.
Write error occurred for address <address> on device <channel.device>. FWLIB error: <code>.
Write to address <address> on device <device>: The program number <number> does not exist on the controller.
Fanuc Focas Server Device Driver Error Messages
Attempt to launch unsolicited message server failed.
Could not access necessary system resources for Fanuc Focas server device: <channel.device>.
Failed to connect Fanuc Focas server device <channel.device>. Could not acquire library handle. FWLIB error: <code>.
Failed to connect Fanuc Focas server device <channel.device>. Could not determine host IP address.
Failed to connect Fanuc Focas server device <channel.device>. Could not set data area size.
Failed to connect Fanuc Focas server device <channel.device>. Could not set data area start address.
Failed to connect Fanuc Focas server device <channel.device>. Could not set data area type.
Failed to connect Fanuc Focas server device <channel.device>. Could not set host IP.
Failed to connect Fanuc Focas server device <channel.device>. Could not set host port.
Failed to connect Fanuc Focas server device <channel.device>. Could not set message alive time.
Failed to connect Fanuc Focas server device <channel.device>. Could not set message retries.
Failed to connect Fanuc Focas server device <channel.device>. Could not set message timeout.
Failed to connect Fanuc Focas server device <channel.device>. Could not set messaging parameters. FWLIB data error <code>.
Failed to connect Fanuc Focas server device <channel.device>. Could not set messaging parameters. FWLIB error: <code>.
Failed to connect Fanuc Focas server device <channel.device>. Could not set number of data areas.
Failed to connect Fanuc Focas server device <channel.device>. Could not set request timeout. FWLIB error: <code>.
Failed to connect Fanuc Focas server device <channel.device>. Could not set transmission control PMC type.
Failed to connect Fanuc Focas server device <channel.device>. Could not set transmission control start address.
Failed to connect Fanuc Focas server device <channel.device>. Could not start messaging session. FWLIB error: <code>.
Installed version of Focas Data Window Library does not support unsolicited communication. Device <device> deactivated.
Received CNC power down notification from unsolicited message server. Reconnecting Fanuc Focas server devices.
Received CNC power up notification from unsolicited message server.
Received socket error notification from unsolicited message server.
Received unsolicited message server shutdown notification.
Unsolicited message server does not seem to be running. Attempting to launch.
Focas 1 Data Window Library Error Codes
Appendix — API Calls
Fanuc Focas HSSB
Overview
External Dependencies
Install Focas Library
Setup
Channel Properties — General
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Communications Parameters
Optimizing Fanuc Focas HSSB Communications
Data Types Description
Address Descriptions
Series 15i
Series 16i
Series 18i
Series 21i
Power Mate i
Open
CNC Data
Tool Offset
Workpiece Zero Offset
Event Log Messages
Event Log Messages
Focas1 Data Window Library Error Codes
Fisher ROC Ethernet
Overview
Channel Setup
Channel Properties — General
Channel Properties — Ethernet Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Channel Properties — Communication Serialization
Device Setup
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Tag Generation
Device Properties — Time Synchronization
Device Properties — Communication Parameters
Device Properties — Tag Import Settings
Device Properties — Communication Specification
Device Properties — Operator Identification
Device Properties — EFM Meters
EFM Attribute Mapping
Data Type Descriptions
TLP Data Type Conversion Process and Examples
Address Descriptions
ROC Point Types
Logical / Point Number Details
User-Defined Point Types
User Table Points
Bit Assignments
Statistics Items
EFM Pointer Rollback
Event Log Messages
Address Validation
Address <address> is out of range for the specified device or register.
Data type <type> is not valid for device address <address>.
Device address <address> contains a syntax error.
Device address <address> is not supported by model <model name>.
Device address <address> is read only.
Missing address.
Automatic Tag Database Generation Error Messages
Error importing CSV tag record <record number>: Address <address> is out of range for the specified device or register.
Unable to generate a tag database for device <device>. Reason: <Error reason>.
Unable to generate a tag database for device <device>. Reason: Auto tag generation.
Unable to generate a tag database for device <device>. Reason: Error while reading from import file.
Unable to generate a tag database for device <device>. Reason: Error while reading from ROC system file.
Unable to generate a tag database for device <device>. Reason: Failed to open record set.
Unable to generate a tag database for device <device>. Reason: Import file <file name> not found.
Unable to generate a tag database for device <device>. Reason: Input file is corrupt.
Unable to generate a tag database for device <device>. Reason: Import file <file name> not found.
Unable to generate a tag database for device <device>. Reason: Low memory resources.
Unable to generate a tag database for device <device>. Reason: ROC system file <file name> not found.
Unable to generate a tag database for device <device>. Reason: System DB file <file name> not found.
Device Specific Messages
<Device name> - Failed to read EFM pointer file. <Extended error>.
<Device name> - Failed to write EFM pointer file. <Extended error>.
Block read for point type <point type>, logical address <logical address>, parameter range <start parameter - end parameter> of device <device name> failed. Parameters are not in the loaded UDP configuration.
Device <device> responded with error. (Tag <tag address>) - Details: <error code>.
EFM hourly history upload failed for device. Device responded with error code 14.
Failed to obtain data block for point type = <point type>, logical address = <address>, starting parameter = <starting parameter>, ending parameter <ending parameter> for device <device>. Error = <ROC error code>.
Failed to obtain data block for point type = <point type>, logical address = <address>, starting parameter = <starting parameter>, ending parameter <ending parameter> for device <device>. Error = <ROC error code>.
Operator identification failed for device <device name>. <Error reason>.
Read for point type <point type>, logical address <logical address>, parameter number <parameter> of device <device name> failed. Parameter is not in the loaded UDP configuration.
ROC initialization error: Unable to read general configuration.
ROC initialization error: Unable to retrieve I/O map.
Serialization of EFM data to temporary file <file name> failed. Reason: <file I/O error>.
The rollback value has been adjusted to match the archive size because it exceeded the size of the archive | Adjusted Rollback = <size>, Archive = <name>.
The username or password supplied was not accepted. Error = 6.
The username or password supplied was not accepted. Error = 63.
Time synchronization with device <device name> failed. <Error reason>.
Write for the following tags of device <device name> failed: <tag list>. <Error reason>.
Write request rejected on read-only item reference <channel name> <device name>.
Device Status Messages
Device <device name> is not responding.
EFM <type> upload failed for device <device>. <Reason>.
Resetting the EFM cache for device <device>.
User Configurable Table Messages
Block read for user table <table number>, location range <start location> - <end location> of device <device name> failed. Device returned error code <error code>.
Block read for user table <table number>, location range <start location> - <end location> of device <device name> failed. Framing error.
Block read for user table <table number>, location range <start location> - <end location> of device <device name> failed. Locations are not configured in the user table.
User Table Points
Error parsing user table configuration on device <device name>. User table <table number> contains an invalid user-defined point type, location, or parameter in table location <location address>.
Read for user table <table number>, location <location address> of device <device name> failed. Device returned error code <error code>.
Read for user table <table number>, location <location address> of device <device name> failed. Framing error.
Read for user table <table number>, location <location address> of device <device name> failed. Location is not configured in the user table.
Read for user table <table number>, location <location address> of device <device name> failed. Device returned error code <error code>.
User table configuration upload on device <device name> failed. Device not responding.
User table configuration upload on device <device name> failed. Framing error.
User table configuration upload on device <device name> failed. Internal error.
User-Defined Point Error Messages
Block read for point type <point type>, logical address <logical address>, parameter range <start parameter - end parameter> of device <device name> failed. Parameters are not in the loaded UDP configuration.
Read for point type <point type>, logical address <logical address>, parameter number <parameter> of device <device name> failed. Parameter is not in the loaded UDP configuration.
Unable to load user-defined point configuration for point type <point type>, logical address <logical address>, parameter number <parameter> of device <device name>. The number of parameters for this point is 0.
Unable to parse the user-defined point configuration information for point type <point type> on device <device name>.
User-defined point configuration upload for point type <point type>, logical address <logical address>, parameter number <parameter> of device <device name> failed. <Error reason>.
ROC Error Codes
Error Reasons
Fisher ROC Plus Ethernet
Overview
Channel Setup
Channel Properties — General
Channel Properties — Ethernet Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Channel Properties — Communication Serialization
Device Setup
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Tag Generation
Device Properties — Time Synchronization
Device Properties — Communication Parameters
Device Properties — Tag Import Settings
Device Properties — Communication Specification
Device Properties — Operator Identification
Meter Properties — General
EFM Attribute Mapping
PLUS Data Type Descriptions
TLP Data Type Conversion Process and Examples
Address Descriptions
ROC Plus Point Types
Logical / Location Details
User-Defined Point Types
User Table Points
Binary Field (BIN) Example
Statistics Items
EFM Pointer Rollback
Event Log Messages
Address Validation
Address <address> is out of range for the specified device or register.
Data type <type> is not valid for device address <address>.
Device address <address> contains a syntax error.
Device address <address> is not supported by model <model name>.
Device address <address> is read only.
Missing address.
Automatic Tag Database Generation Error Messages
Error importing CSV tag record <record number>: Address <address> is out of range for the specified device or register.
Unable to generate a tag database for device <device>. Reason: <Error reason>.
Unable to generate a tag database for device <device>. Reason: Auto tag generation.
Unable to generate a tag database for device <device>. Reason: Error while reading from import file.
Unable to generate a tag database for device <device>. Reason: Error while reading from ROC system file.
Unable to generate a tag database for device <device>. Reason: Failed to open record set.
Unable to generate a tag database for device <device>. Reason: Import file <file name> not found.
Unable to generate a tag database for device <device>. Reason: Input file is corrupt.
Unable to generate a tag database for device <device>. Reason: Import file <file name> not found.
Unable to generate a tag database for device <device>. Reason: Low memory resources.
Unable to generate a tag database for device <device>. Reason: ROC system file <file name> not found.
Unable to generate a tag database for device <device>. Reason: System DB file <file name> not found.
Device Specific Messages
<Device name> - Failed to read EFM pointer file. <Extended error>.
<Device name> - Failed to write EFM pointer file. <Extended error>.
Block read for point type <point type>, logical address <logical address>, parameter range <start parameter - end parameter> of device <device name> failed. Parameters are not in the loaded UDP configuration.
Device <device> responded with error. (Tag <tag address>) - Details: <error code>.
EFM hourly history upload failed for device. Device responded with error code 14.
Failed to obtain data block for point type = <point type>, logical address = <address>, starting parameter = <starting parameter>, ending parameter <ending parameter> for device <device>. Error = <ROC error code>.
Failed to obtain data block for point type = <point type>, logical address = <address>, starting parameter = <starting parameter>, ending parameter <ending parameter> for device <device>. Error = <ROC error code>.
Operator identification failed for device <device name>. <Error reason>.
Read for point type <point type>, logical address <logical address>, parameter number <parameter> of device <device name> failed. Parameter is not in the loaded UDP configuration.
ROC initialization error: Unable to read general configuration.
ROC initialization error: Unable to retrieve I/O map.
Serialization of EFM data to temporary file <file name> failed. Reason: <file I/O error>.
The rollback value has been adjusted to match the archive size because it exceeded the size of the archive | Adjusted Rollback = <size>, Archive = <name>.
The username or password supplied was not accepted. Error = 6.
The username or password supplied was not accepted. Error = 63.
Time synchronization with device <device name> failed. <Error reason>.
Write for the following tags of device <device name> failed: <tag list>. <Error reason>.
Write request rejected on read-only item reference <channel name> <device name>.
Device Status Messages
Device <device name> is not responding.
EFM <type> upload failed for device <device>. <Reason>.
Resetting the EFM cache for device <device>.
User Configurable Table Messages
Block read for user table <table number>, location range <start location> - <end location> of device <device name> failed. Device returned error code <error code>.
Block read for user table <table number>, location range <start location> - <end location> of device <device name> failed. Framing error.
Block read for user table <table number>, location range <start location> - <end location> of device <device name> failed. Locations are not configured in the user table.
User Table Points
Error parsing user table configuration on device <device name>. User table <table number> contains an invalid user-defined point type, location, or parameter in table location <location address>.
Read for user table <table number>, location <location address> of device <device name> failed. Device returned error code <error code>.
Read for user table <table number>, location <location address> of device <device name> failed. Framing error.
Read for user table <table number>, location <location address> of device <device name> failed. Location is not configured in the user table.
Read for user table <table number>, location <location address> of device <device name> failed. Device returned error code <error code>.
User table configuration upload on device <device name> failed. Device not responding.
User table configuration upload on device <device name> failed. Framing error.
User table configuration upload on device <device name> failed. Internal error.
User-Defined Point Error Messages
Block read for point type <point type>, logical address <logical address>, parameter range <start parameter - end parameter> of device <device name> failed. Parameters are not in the loaded UDP configuration.
Read for point type <point type>, logical address <logical address>, parameter number <parameter> of device <device name> failed. Parameter is not in the loaded UDP configuration.
Unable to load user-defined point configuration for point type <point type>, logical address <logical address>, parameter number <parameter> of device <device name>. The number of parameters for this point is 0.
Unable to parse the user-defined point configuration information for point type <point type> on device <device name>.
User-defined point configuration upload for point type <point type>, logical address <logical address>, parameter number <parameter> of device <device name> failed. <Error reason>.
ROC Plus Error Codes
Fisher ROC Plus Serial
Overview
Channel Setup
Channel Properties — General
Channel Properties — Serial Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Channel Properties — Communication Serialization
Device Setup
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Tag Generation
Device Properties — Time Synchronization
Device Properties — Tag Import Settings
Device Properties — Communication Specification
Device Properties — Operator Identification
Meter Properties — General
EFM Attribute Mapping
PLUS Data Type Descriptions
TLP Data Type Conversion Process and Examples
Address Descriptions
Logical / Location Details
ROC Plus Point Types
User-Defined Point Types
User Table Points
Binary Field (BIN) Example
Statistics Items
EFM Pointer Rollback
Event Log Messages
Address Validation
Address <address> is out of range for the specified device or register.
Data type <type> is not valid for device address <address>.
Device address <address> contains a syntax error.
Device address <address> is not supported by model <model name>.
Device address <address> is read only.
Missing address.
Automatic Tag Database Generation Error Messages
Error importing CSV tag record <record number>: Address <address> is out of range for the specified device or register.
Unable to generate a tag database for device <device>. Reason: <Error reason>.
Unable to generate a tag database for device <device>. Reason: Auto tag generation.
Unable to generate a tag database for device <device>. Reason: Error while reading from import file.
Unable to generate a tag database for device <device>. Reason: Error while reading from ROC system file.
Unable to generate a tag database for device <device>. Reason: Failed to open record set.
Unable to generate a tag database for device <device>. Reason: Import file <file name> not found.
Unable to generate a tag database for device <device>. Reason: Input file is corrupt.
Unable to generate a tag database for device <device>. Reason: Import file <file name> not found.
Unable to generate a tag database for device <device>. Reason: Low memory resources.
Unable to generate a tag database for device <device>. Reason: ROC system file <file name> not found.
Unable to generate a tag database for device <device>. Reason: System DB file <file name> not found.
Device Specific Messages
<Device name> - Failed to read EFM pointer file. <Extended error>.
<Device name> - Failed to write EFM pointer file. <Extended error>.
Block read for point type <point type>, logical address <logical address>, parameter range <start parameter - end parameter> of device <device name> failed. Parameters are not in the loaded UDP configuration.
Device <device> responded with error. (Tag <tag address>) - Details: <error code>.
EFM hourly history upload failed for device. Device responded with error code 14.
Failed to obtain data block for point type = <point type>, logical address = <address>, starting parameter = <starting parameter>, ending parameter <ending parameter> for device <device>. Error = <ROC error code>.
Failed to obtain data block for point type = <point type>, logical address = <address>, starting parameter = <starting parameter>, ending parameter <ending parameter> for device <device>. Error = <ROC error code>.
Operator identification failed for device <device name>. <Error reason>.
Read for point type <point type>, logical address <logical address>, parameter number <parameter> of device <device name> failed. Parameter is not in the loaded UDP configuration.
ROC initialization error: Unable to read general configuration.
ROC initialization error: Unable to retrieve I/O map.
Serialization of EFM data to temporary file <file name> failed. Reason: <file I/O error>.
The rollback value has been adjusted to match the archive size because it exceeded the size of the archive | Adjusted Rollback = <size>, Archive = <name>.
The username or password supplied was not accepted. Error = 6.
The username or password supplied was not accepted. Error = 63.
Time synchronization with device <device name> failed. <Error reason>.
Write for the following tags of device <device name> failed: <tag list>. <Error reason>.
Write request rejected on read-only item reference <channel name> <device name>.
Device Status Messages
Device <device name> is not responding.
EFM <type> upload failed for device <device>. <Reason>.
Resetting the EFM cache for device <device>.
User Configurable Table Messages
Block read for user table <table number>, location range <start location> - <end location> of device <device name> failed. Device returned error code <error code>.
Block read for user table <table number>, location range <start location> - <end location> of device <device name> failed. Framing error.
Block read for user table <table number>, location range <start location> - <end location> of device <device name> failed. Locations are not configured in the user table.
User Table Points
Error parsing user table configuration on device <device name>. User table <table number> contains an invalid user-defined point type, location, or parameter in table location <location address>.
Read for user table <table number>, location <location address> of device <device name> failed. Device returned error code <error code>.
Read for user table <table number>, location <location address> of device <device name> failed. Framing error.
Read for user table <table number>, location <location address> of device <device name> failed. Location is not configured in the user table.
Read for user table <table number>, location <location address> of device <device name> failed. Device returned error code <error code>.
User table configuration upload on device <device name> failed. Device not responding.
User table configuration upload on device <device name> failed. Framing error.
User table configuration upload on device <device name> failed. Internal error.
User-Defined Point Error Messages
Block read for point type <point type>, logical address <logical address>, parameter range <start parameter - end parameter> of device <device name> failed. Parameters are not in the loaded UDP configuration.
Read for point type <point type>, logical address <logical address>, parameter number <parameter> of device <device name> failed. Parameter is not in the loaded UDP configuration.
Unable to load user-defined point configuration for point type <point type>, logical address <logical address>, parameter number <parameter> of device <device name>. The number of parameters for this point is 0.
Unable to parse the user-defined point configuration information for point type <point type> on device <device name>.
User-defined point configuration upload for point type <point type>, logical address <logical address>, parameter number <parameter> of device <device name> failed. <Error reason>.
ROC Plus Error Codes
Error Reasons
Fisher ROC Serial
Overview
Channel Setup
Channel Properties — General
Channel Properties — Serial Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Channel Properties — Communication Serialization
Device Setup
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Tag Generation
Device Properties — Time Synchronization
Device Properties — Tag Import Settings
Device Properties — Communication Specification
Device Properties — Operator Identification
Meter Properties — General
EFM Attribute Mapping
Data Type Descriptions
TLP Data Type Conversion Process and Examples
Address Descriptions
ROC Point Types
Logical / Point Number Details
User-Defined Point Types
User Table Points
Bit Assignments
Statistics Items
EFM Pointer Rollback
Event Log Messages
Address Validation
Address <address> is out of range for the specified device or register.
Data type <type> is not valid for device address <address>.
Device address <address> contains a syntax error.
Device address <address> is not supported by model <model name>.
Device address <address> is read only.
Missing address.
Automatic Tag Database Generation Error Messages
Error importing CSV tag record <record number>: Address <address> is out of range for the specified device or register.
Unable to generate a tag database for device <device>. Reason: <Error reason>.
Unable to generate a tag database for device <device>. Reason: Auto tag generation.
Unable to generate a tag database for device <device>. Reason: Error while reading from import file.
Unable to generate a tag database for device <device>. Reason: Error while reading from ROC system file.
Unable to generate a tag database for device <device>. Reason: Failed to open record set.
Unable to generate a tag database for device <device>. Reason: Import file <file name> not found.
Unable to generate a tag database for device <device>. Reason: Input file is corrupt.
Unable to generate a tag database for device <device>. Reason: Input file not found.
Unable to generate a tag database for device <device>. Reason: Low memory resources.
Unable to generate a tag database for device <device>. Reason: ROC system file <file name> not found.
Unable to generate a tag database for device <device>. Reason: System DB file <file name> not found.
Device Specific Messages
<Device name> - Failed to read EFM pointer file. <Extended error>.
<Device name> - Failed to write EFM pointer file. <Extended error>.
Block read for point type <point type>, logical address <logical address>, parameter range <start parameter - end parameter> of device <device name> failed. <Error reason>.
Device <device> responded with error. (Tag <tag address>) - Details: <error code>.
EFM hourly history upload failed for device. Device responded with error code 14.
Failed to obtain data block for point type = <point type>, logical address = <address>, starting parameter = <starting parameter>, ending parameter <ending parameter> for device <device>. Error = <ROC error code>.
Failed to write data for point type = <point type>, logical address = <address>, parameter = <parameter> for device <device>. Error = <error code>.
Operator identification failed for device <device name>. <Error reason>.
Read for point type <point type>, logical address <logical address>, parameter number <parameter number> of device <device name> failed. <Error reason>.
ROC initialization error: Unable to read general configuration.
ROC initialization error: Unable to retrieve I/O map.
Serialization of EFM data to temporary file <file name> failed. Reason: <file I/O error>.
The rollback value has been adjusted to match the archive size because it exceeded the size of the archive | Adjusted Rollback = <size>, Archive = <name>.
The username or password supplied was not accepted. Error = 6.
The username or password supplied was not accepted. Error = 63.
Time synchronization with device <device name> failed. <Error reason>.
Write for the following tags of device <device name> failed: <tag list>. <Error reason>.
Write request rejected on read-only item reference <channel name> <device name> <address>.
Device Status Messages
Device <device name> is not responding.
EFM <type> upload failed for device <device>. <Reason>.
Resetting the EFM cache for device <device>.
Serial Communications
Communications error on <channel name> [<error mask>].
COMn does not exist.
COMn is in use by another application.
Error opening COMn.
Unable to set comm parameters on COMn.
User Configurable Table Messages
Block read for user table <table number>, location range <start location> - <end location> of device <device name> failed. Device returned error code <error code>.
Block read for user table <table number>, location range <start location> - <end location> of device <device name> failed. Framing error.
Block read for user table <table number>, location range <start location> - <end location> of device <device name> failed. Locations are not configured in the user table.
Error parsing user table configuration on device <device name>. User table <table number> contains an invalid user-defined point type, location, or parameter in table location <location address>.
Error parsing user table configuration on device <device name>. User table <table number> contains an invalid point type, location, or parameter in table location <location address>.
Read for user table <table number>, location <location address> of device <device name> failed. Device returned error code <error code>.
Read for user table <table number>, location <location address> of device <device name> failed. Framing error.
Read for user table <table number>, location <location address> of device <device name> failed. Location is not configured in the user table.
User table configuration upload on device <device name> failed. Device not responding.
User table configuration upload on device <device name> failed. Device responded with error code <error code>.
User table configuration upload on device <device name> failed. Framing error.
User table configuration upload on device <device name> failed. Internal error.
User-Defined Point Error Messages
Block read for point type <point type>, logical address <logical address>, parameter range <start parameter - end parameter> of device <device name> failed. Parameters are not in the loaded UDP configuration.
Read for point type <point type>, logical address <logical address>, parameter number <parameter> of device <device name> failed. Parameter is not in the loaded UDP configuration.
Unable to load user-defined point configuration for point type <point type>, logical address <logical address>, parameter number <parameter> of device <device name>. The number of parameters for this point is 0.
Unable to parse the user-defined point configuration information for point type <point type> on device <device name>.
User-defined point configuration upload for point type <point type>, logical address <logical address>, parameter number <parameter> of device <device name> failed. <Error reason>.
ROC Error Codes
Error Reasons
Fuji Flex
Overview
Setup
Channel Properties — General
Channel Properties — Write Optimizations
Channel Properties — Serial Communications
Channel Properties — Advanced
Channel Properties — Interface Options
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Block Size
Data Types Description
Address Descriptions
NB0 Model Address Descriptions
Open Model Address Descriptions
Error Descriptions
Address Validation
Missing address
Device address '<address>' contains a syntax error
Address '<address>' is out of range for the specified device or register
Device address '<address>' is not supported by model '<model name>'
Data Type '<type>' is not valid for device address '<address>'
Device address '<address>' is Read Only
Serial Communications
COMn does not exist
Error opening COMn
COMn is in use by another application
Unable to set comm properties on COMn
Communications error on '<channel name>' [<error mask>]
Device Status Messages
Device '<device name> not responding
Unable to write to '<address>' on device '<device name>'
Driver Specific Messages
Device '<device name>' returned 'Parameter Error' probably caused by a bad address in block (Tag:'<address>', Size: <size> bytes). Block deactivated
Device '<device name>' returned 'Processing is impossible due to transmission interlock by another device or loader' (Tag: '<address>', Size <size> bytes)
Device '<device name>' returned 'Incorrect module number' probably due to unsupported memory type. (Tag: '<address>', Size: <size> bytes). Block deactivated
Device '<device name>' returned 'Connection to network is impossible' (Tag: '<address>', Size: <size> bytes)
Device '<device name>' returned 'Address exceeding the module's range was specified during write' (Tag: '<address>', Size: <size> bytes)
Device '<device name>' returned 'Another loader is communicating over the network' (Tag: '<address>', Size: <size> bytes)
Device '<device name>' returned 'Transmission error' (Tag: '<address>', Size: <size> bytes)
Device '<device name>' returned error code: '<code>'. (Tag: '<address>', Size: <size> bytes
Received a bad check sum (Device: '<device name>', Tag: '<address>', Size: <size> bytes)
Response had unexpected format (Device: '<device name>', Tag: '<address>', Size: <size> bytes)
Response had incorrect data size (Device: '<device name>', Tag: '<tag name>', Size: <size> bytes)
G-L Drivers
GE CCM
Overview
Setup
Channel Properties — General
Channel Properties — Serial Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Channel Properties — Communication Serialization
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Data Types Description
Address Descriptions
311 Addressing
313 Addressing
331 Addressing
341 Addressing
731 Addressing
732 Addressing
771 Addressing
772 Addressing
781 Addressing
782 Addressing
Series Six Addressing
Series Five Addressing
Event Log Messages
Address Validation
Missing address
Device address '<address>' contains a syntax error
Address '<address>' is out of range for the specified device or register
Device address '<address>' is not supported by model '<model name>'
Data Type '<type>' is not valid for device address '<address>'
Device address '<address>' is Read Only
Array size is out of range for address '<address>'
Array support is not available for the specified address: '<address>'
Address '<address>' is not valid on device '<device name>'
Serial Communications
COMn is in use by another application
Error opening COMn
COMn does not exist
Unable to set comm parameters on COMn
Communications error on '<channel name>' [<error mask>]
Device Status Messages
Device '<device name> not responding
Unable to write to '<address>' on device '<device name>'
Unable to write to tag '<address>' on device '<device name>.' Invalid Request
Unable to read tag '<address>' on device '<device name>.' Invalid Request.
Unable to read '<count>' bytes starting at '<address>' on device '<device name>'. Invalid Request
Unable to write to tag '<address>' on device'<device name>'. Framing Error
Unable to read tag '<address>' on device '<device name>'. Framing Error
Unable to read '<count>' bytes starting at '<address>' on device '<device name>'. Framing Error
Device Specific Messages
Invalid tag in block starting at <address> in device <device>
HGE EGD
Overview
Setup
Channel Properties — General
Channel Properties — Ethernet Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Tag Generation
Exchange Configuration
Name Resolutions
Data Types Description
Address Descriptions
Error Descriptions
Address Validation
Address '<address>' is out of range for the specified device or register
Array size is out of range for address '<address>'
Array support is not available for the specified address: '<address>'
Data Type '<type>' is not valid for device address '<address>'
Device address '<address>' contains a syntax error
Device address '<address>' is not supported by model '<model name>'
Device address '<address>' is Read Only
Missing address.
GE Ethernet Global Data Device Specific Messages
Consumer exchange (<Exchange ID>) on channel '<channel>' contains an invalid signature from producer (<producer IP>)
Consumer exchange (<Exchange ID>) on channel '<channel>' is not receiving production data from producer (<producer IP>)
Consumer exchange (<Exchange ID>) on channel '<channel>' is not receiving updates within the configured period (elapsed time <time>ms)
Consumer exchange (<Exchange ID>) on channel '<channel>' is receiving an unsynchronized timestamp from producer (<producer IP>
Consumer exchange (<Exchange ID>) on channel '<channel>' is receiving out of date data from producer (<producer IP>)
No exchanges have been configured. Tags not generated
Non-production exchange (<Exchange ID>) received from producer (<producer IP>)
Received exchange (<Exchange ID>) with an unsupported protocol version (<protocol version received>) from producer (<producer IP>)
The driver has not been properly configured to receive exchange (<Exchange ID>) from producer (<producer IP>)
The xml file contains an alias name which has illegal characters. Only alphanumeric and underscore characters are valid
Unable to bind consumer socket on '<device>'. (Error Code = <error code>)
Unable to bind producer socket required for multicasting on '<device>'. (Error Code = <error code>)
Unable to Bind to Adapter: '<adapter>'. Connect failed
Unable to create a producer socket on '<device>'. (Error Code = <error code>)
Unable to create a consumer socket on '<device>'. (Error Code = <error code>)
Unable to determine host name for producing node. (Error Code = <error code>)
Unable to get host address for producing node. (Error Code = <error code>)
Unable to join multicast group on '<IP address>'. (Error Code = <error code>)
Unable to read producer exchange (<Exchange ID>) configuration data on channel '<channel>'. Terminating producer exchange
Unable to reuse consumer socket on '<device>'. (Error Code = <error code>)
Unable to set time to live for multicasted socket on '<device>'. (Error Code = <error code>)
Winsock initialization failed (OS Error = n)
Winsock V1.1 or higher must be installed to use the GE Ethernet device driver
Configuring EGD
Configuring EGD in VersaPro and the OPC Server
Configuring EGD in GE Proficy Machine Edition
GE Ethernet
Overview
Setup
Channel Properties
Channel Properties — General
Channel Properties — Ethernet Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Tag Generation
Device Properties — Communications Settings
Device Properties — Variable Import Settings
Device Properties — PLC Settings
Automatic Tag Database Generation
Tag Hierarchy
Import File-to-Server Name Conversions
Importing VersaPro Tags
Importing VersaPro Tags
VersaPro Import Preparation: VersaPro Steps
VersaPro Import Preparation: OPC Server Steps
Highlighting VersaPro Variables
VersaPro Array Tag Import
Importing Cimplicity Logic Developer Tags
Importing Cimplicity Logic Developer Tags
Cimplicity Logic Developer Import Preparation: Logic Developer Steps
Cimplicity Logic Developer Import Preparation: OPC Server Steps
Highlighting Cimplicity Logic Developer Variables
Cimplicity Logic Developer Array Tag Import
Importing Proficy Logic Developer Tags
Importing Proficy Logic Developer Tags
Proficy Logic Developer Import Preparation: Logic Developer Steps
Proficy Logic Developer Import Preparation: OPC Server Steps
Highlighting Proficy Logic Developer Variables
Proficy Logic Developer Array Tag Import
Optimizing Communications
Data Types Description
Address Descriptions
PACSystems Addressing
Symbolic Variables
311 Addressing
313 Addressing
331 Addressing
341 Addressing
350 Addressing
360 Addressing
731 Addressing
732 Addressing
771 Addressing
772 Addressing
781 Addressing
782 Addressing
GE OPEN Addressing
Horner OCS Addressing
VersaMax Addressing
Advanced Addressing
Special Items
Error Descriptions
Address Validation
Address '<address>' is out of range for the specified device or register
Array size is out of range for address '<address>'
Array support is not available for the specified address: '<address>'
Data Type '<type>' is not valid for device address '<address>'
Device address '<address>' contains a syntax error
Device address '<address>' is not supported by model '<model name>'
Device address '<address>' is Read Only
Missing address
Device Status Messages
Attempting to reacquire symbolic variable mapping information for device '<device name>'. Cannot read or write symbolic variables until complete
Device '<device name> not responding
Unable to write to '<address>' on device '<device name>'
Driver Error Messages
Bit access is invalid for the device data type '<native data type>' at address '<address>' in device '<device>'
Bit index '<bit index>' is not valid for the device data type '<native data type>' at address '<address>' in device '<device>'
Device '<device name>' returned error code <error num> reading n byte(s) starting at <address>
The address length of the symbolic variable addressed by '<tag name>' on device '<device>' is bigger
The array size of address '<address>' on device '<device name>' must be the same as symbolic variable's array size of [rows][cols]
The data type of the symbolic variable addressed by '<address>' on device '<device name>' is not compatible with tag
The symbolic discrete array size of '<size in bytes>' bytes at address '<address>' on device '<device>' exceeds the configured '<block size>' maximum request bytes
The symbolic variable name in tag address '<address>' does not exist in current configuration of device '<device name>'
Winsock initialization failed (OS Error = n)
Winsock V1.1 or higher must be installed to use the GE Ethernet device driver
Automatic Tag Database Generation Messages
Database Error: Array tags [orig. tag name] [dimensions] exceed 256 characters. Tags renamed to [new tag name] [dimensions]
Database Error: Data type '<type>' arrays are currently not supported. Tag '<array tag name>' not created
Database Error: Data type '<type>' for tag '<tag name>' is currently not supported. Tag not created
Database Error: Data type '<type>' for tag '<tag name>' not found in import file. Setting to default
Database Error: Logic Developer Variable Arrays are currently not supported. Array Tag(s) '<array tag name>' not created
Database Error: No Reference Address found for tag '<tag name>' in import file. Tag not created
Database Error: Only variables with Data Source '<data source name>' are imported. Data Source '<data soure name>' is not..
Database Error: Tag '<orig. tag name>' exceeds 256 characters. Tag renamed to '<new tag name>'
Unable to generate a tag database for device <device name>. Reason: Import file is invalid or corrupt
Unable to generate a tag database for device <device name>. Reason: Low memory resources
GE SNP
Overview
Setup
Channel Properties — General
Channel Properties — Serial Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Channel Properties — Communication Serialization
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Tag Generation
Device Properties — Variable Import Settings
Data Types Description
Automatic Tag Database Generation
Tag Hierarchy
Import File-to-Server Name Conversions
Address Descriptions
GE Micro Addressing
311 Addressing
313 Addressing
331 Addressing
341 Addressing
350 Addressing
360 Addressing
731 Addressing
732 Addressing
771 Addressing
772 Addressing
781 Addressing
782 Addressing
GE OPEN Addressing
Advanced Addressing
Error Descriptions
Address Validation
Missing address
Device address '<address>' contains a syntax error
Address '<address>' is out of range for the specified device or register
Device address '<address>' is not supported by model '<model name>.'
Data Type '<type>' is not valid for device address '<address>'
Device address '<address>' is Read Only
Array size is out of range for address '<address>'
Array support is not available for the specified address: '<address>'
Serial Communications
COMn does not exist
Error opening COMn
COMn is in use by another application
Unable to set comm parameters on COMn
Communications error on '<channel name>' [<error mask>]
Device Status Messages
Device '<device name> not responding
Unable to write to '<address>' on device '<device name>'
Device Specific Messages
Invalid tag in block starting at <address> on device <device name>. Block deactivated
Write Error Messages
Unable to write to tag '<tag address>' on device '<device name>'. The service requested is either not defined or not supported
Unable to write to tag '<tag address>' on device '<device name>'. The user does not have sufficient privileges to process the request. Minor status error code = '<hexadecimal error code>'
Unable to write to tag '<tag address>' on device '<device name>'. The CPU has received a message that is out of order
Unable to write to tag '<tag address>' on device '<device name>'. Service request error. Minor status error code = '<hexadecimal error code>'
Unable to write to tag '<tag address>' on device '<device name>'. Service request mailbox type is either undefined or unexpected
Unable to write to tag '<tag address>' on device '<device name>'. The PLC CPU's service request queue is full: please wait a minimum of 10 ms before sending another service request
Unable to write to tag '<tag address>' on device '<device name>'. A framing error has occurred
Unable to write to tag '<tag address>' on device '<device name>'. Device returned major error code '<hexadecimal error code>' and minor error code '<hexadecimal error code>'
Blocked Reads Error Messages
Unable to read '<number of bytes>' bytes starting at address '<tag address>' on device '<device name>'. The service requested is either not defined or not supported
Unable to read '<number of bytes>' bytes starting at address '<tag address>' on device '<device name>'. The user does not have sufficient privileges to process the request. Minor status error code = '<hexadecimal error code>'
Unable to read '<number of bytes>' bytes starting at address '<tag address>' on device '<device name>'. The CPU has received a message that is out of order
Unable to read '<number of bytes>' bytes starting at address '<tag address>' on device '<device name>'. Service request error. Minor status error code = '<hexadecimal error code>'
Unable to read '<number of bytes>' bytes starting at address '<tag address>' on device '<device name>'. Service request mailbox type is either undefined or unexpected
Unable to read '<number of bytes>' bytes starting at address '<tag address>' on device '<device name>'. The PLC CPU's service request queue is full: please wait a minimum of 10 ms before sending another service request
Unable to read '<byte count>' bytes starting at address '<start tag>' on device '<device name>'. A framing error has occurred
Unable to read '<number of bytes>' bytes starting at address '<tag address>' on device '<device name>'. Device returned major error code '<hexadecimal error code>' and minor error code '<hexadecimal error code>'
Non-Blocked Reads Error Messages
Unable to read tag '<tag address>' on device '<device name>'. The service requested is either not defined or not supported
Unable to read tag '<tag address>' on device '<device name>'. The user does not have sufficient privileges to process the request. Minor status error code = '<hexadecimal error code>'
Unable to read tag '<tag address>' on device '<device name>'. The CPU has received a message that is out of order
Unable to read tag '<tag address>' on device '<device name>'. Service request error. Minor status error code = '<hexadecimal error code>'
Unable to read tag '<tag address>' on device '<device name>'. Service request mailbox type is either undefined or unexpected
Unable to read tag '<tag address>' on device '<device name>'. The PLC CPU's service request queue is full: please wait a minimum of 10 ms before sending another service request
Unable to read tag '<tag address>' on device '<device name>'. A framing error has occurred
Unable to read tag '<tag address>' on device '<device name>'. Device returned major error code '<hexadecimal error code>' and minor error code '<hexadecimal error code>'
Automatic Tag Database Generation Messages
Unable to generate a tag database for device <device name>. Reason: Import file is invalid or corrupt
Unable to generate a tag database for device <device name>. Reason: Low memory resources
Database Error: Tag '<orig. tag name>' exceeds 256 characters. Tag renamed to '<new tag name>'
Database Error: Array tags '<orig. tag name><dimensions>' exceed 256 characters. Tags renamed to '<new tag name><dimensions>'
Database Error: Datatype '<type>' for tag '<tag name>' not found in import file. Setting to default
Database Error: Datatype '<type>' for tag '<tag name>' is currently not supported. Tag not created
Database Error: Logic Developer Variable Arrays are currently not supported. Array Tag(s) '<array tag name>' not created
Database Error: No Reference Address found for tag '<tag name>' in import file. Tag not created
Database Error: Only variables with Data Source '<data source name>' are imported. Data Source '<data soure name>' is not..
Database Error: Data type '<type>' arrays are currently not supported. Tag '<array tag name>' not created
Appendix: Creating Tag Import Files
Importing VersaPro Tags
VersaPro Import Preparation: VersaPro Steps
VersaPro Import Preparation: OPC Server Steps
Highlighting VersaPro Variables
VersaPro Array Tag Import
Importing LogicDeveloper Tags
LogicDeveloper Import Preparation: LogicDeveloper Steps
LogicDeveloper Import Preparation: OPC Server Steps
Highlighting LogicDeveloper Variables
LogicDeveloper Array Tag Import
Importing Proficy Logic Developer Tags
Proficy Logic Developer Import Preparation: Logic Developer Steps
Proficy Logic Developer Import Preparation: OPC Server Steps
Highlighting Proficy Logic Developer Variables
Proficy Logic Developer Array Tag Import
GE SNPX
Overview
Setup
Channel Properties — General
Channel Properties — Serial Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Channel Properties — Communication Serialization
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Tag Generation
Device Properties — Variable Import Settings
Data Types Description
Address Descriptions
GE Micro
311 Addressing
313 Addressing
331 Addressing
341 Addressing
350 Addressing
360 Addressing
731 Addressing
732 Addressing
771 Addressing
772 Addressing
781 Addressing
782 Addressing
GE OPEN Addressing
Advanced Addressing
Automatic Tag Database Generation
Tag Hierarchy
Import File-to-Server Name Conversions
Importing VersaPro Tags
VersaPro Import Preparation: VersaPro Steps
VersaPro Import Preparation: OPC Server Steps
Highlighting VersaPro Variables
VersaPro Array Tag Import
Importing LogicDeveloper Tags
LogicDeveloper Import Preparation: LogicDeveloper Steps
LogicDeveloper Import Preparation: OPC Server Steps
Highlighting LogicDeveloper Variables
LogicDeveloper Array Tag Import
Importing Proficy Logic Developer Tags
Proficy Logic Developer Import Preparation: Logic Developer Steps
Proficy Logic Developer Import Preparation: OPC Server Steps
Highlighting Proficy Logic Developer Variables
Proficy Logic Developer Array Tag Import
Error Descriptions
Address Validation
Missing address
Device address '<address>' contains a syntax error
Address '<address>' is out of range for the specified device or register
Device address '<address>' is not supported by model '<model name>'
Data Type '<type>' is not valid for device address '<address>'
Device address '<address>' is Read Only
Array size is out of range for address '<address>'
Array support is not available for the specified address: '<address>'
Serial Communications
COMn does not exist
Error opening COMn
COMn is in use by another application
Unable to set comm parameters on COMn
Communications error on '<channel name>' [<error mask>]
Device Status Messages
Device '<device name> not responding
Unable to write to '<address>' on device '<device name>'
Device Specific Messages
Invalid tag in block starting at <address> on device <device name>. Block deactivated
Write Errors
Unable to write to tag '<tag address>' on device '<device name>'. The service requested is either not defined or not supported
Unable to write to tag '<tag address>' on device '<device name>'. The user does not have sufficient privileges to process the request. Minor status error code = '<hexadecimal error code>'
Unable to write to tag '<tag address>' on device '<device name>'. The CPU has received a message that is out of order
Unable to write to tag '<tag address>' on device '<device name>'. Service request error. Minor status error code = '<hexadecimal error code>'
Unable to write to tag '<tag address>' on device '<device name>'. The PLC CPU's service request queue is full: please wait a minimum of 10 ms before sending another service request
Unable to write to tag '<tag address>' on device '<device name>'. A framing error has occurred
Unable to write to tag '<tag address>' on device '<device name>'. Device returned major error code '<hexadecimal error code>' and minor error code '<hexadecimal error code>'
Blocked Read Errors
Unable to read '<number of bytes>' bytes starting at address '<tag address>' on device '<device name>'. The service requested is either not defined or not supported
Unable to read '<number of bytes>' bytes starting at address '<tag address>' on device '<device name>'. The user does not have sufficient privileges to process the request. Minor status error code = '<hexadecimal error code>'
Unable to read '<number of bytes>' bytes starting at address '<tag address>' on device '<device name>'. The CPU has received a message that is out of order
Unable to read '<number of bytes>' bytes starting at address '<tag address>' on device '<device name>'. Service request error. Minor status error code = '<hexadecimal error code>'
Unable to read '<number of bytes>' bytes starting at address '<tag address>' on device '<device name>'. The PLC CPU's service request queue is full: please wait a minimum of 10 ms before sending another service request
Unable to read '<byte count>' bytes starting at address '<start tag>' on device '<device name>'. A framing error has occurred
Unable to read '<number of bytes>' bytes starting at address '<tag address>' on device '<device name>'. Device returned major error code '<hexadecimal error code>' and minor error code '<hexadecimal error code>'
Non-Blocked Read Errors
Unable to read tag '<tag address>' on device '<device name>'. The service requested is either not defined or not supported
Unable to read tag '<tag address>' on device '<device name>'. The user does not have sufficient privileges to process the request. Minor status error code = '<hexadecimal error code>'
Unable to read tag '<tag address>' on device '<device name>'. The CPU has received a message that is out of order
Unable to read tag '<tag address>' on device '<device name>'. Service request error. Minor status error code = '<hexadecimal error code>'
Unable to read tag '<tag address>' on device '<device name>'. The PLC CPU's service request queue is full: please wait a minimum of 10 ms before sending another service request
Unable to read tag '<tag address>' on device '<device name>'. A framing error has occurred
Unable to read tag '<tag address>' on device '<device name>'. Device returned major error code '<hexadecimal error code>' and minor error code '<hexadecimal error code>'
Automatic Tag Database Generation Messages
Unable to generate a tag database for device <device name>. Reason: Low memory resources
Unable to generate a tag database for device <device name>. Reason: Import file is invalid or corrupt
Database Error: Tag '<orig. tag name>' exceeds 256 characters. Tag renamed to '<new tag name>'
Database Error: Array tags '<orig. tag name><dimensions>' exceed 256 characters. Tags renamed to '<new tag name><dimensions>'
Database Error: Datatype '<type>' for tag '<tag name>' is currently not supported. Tag not created
Database Error: Datatype '<type>' for tag '<tag name>' not found in import file. Setting to default
Database Error: Logic Developer Variable Arrays are currently not supported. Array Tag(s) '<array tag name>' not created
Database Error: No Reference Address found for tag '<tag name>' in import file. Tag not created
Database Error: Only variables with Data Source '<data source name>' are imported. Data Source '<data source name>' is not supported
Database Error: Data type '<type>' arrays are currently not supported. Tag '<array tag name>' not created
Honeywell HC900 Ethernet
Overview
Setup
Channel Properties — General
Channel Properties — Ethernet Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Device Properties — Tag Generation
Automatic Tag Database Generation
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — TCP/IP
Device Properties — Settings
Device Properties — Block Sizes
Device Properties — Tag Generation Settings
Device Properties — Tag Import
Data Types Description
Address Descriptions
Output Coils
Input Coils
Internal Registers
Holding Registers
Optimizing Your Honeywell HC Ethernet Communications
Error Descriptions
Address Validation
Missing address
Device address '<address>' contains a syntax error
Address '<address>' is out of range for the specified device or register
Device address '<address>' is not supported by model '<model name>'
Data Type '<type>' is not valid for device address '<address>'
Device address '<address>' is Read Only
Array size is out of range for address '<address>'
Array support is not available for the specified address: '<address>'
Device Status Messages
Device '<device name>' is not responding
Unable to write to '<address>' on device '<device name>'
Device Specific Messages
Failure to initiate 'winsock.dll'
Bad address in block [x to y] on device '<device name>'
Bad received length [x to y] on device '<device name>'
Tag Import Specific Messages
Could not read record <record> - Buffer length exceeded
No tags imported - Unsupported file format
Could not parse expected data (field <field>, record <record>)
Invalid decimal address (field <field>, record <record>)
Invalid tag name '<name>' (field <field>, record <record>) could not be coerced into valid name
Invalid tag name '<old name>' (field <field>, record <record>) changed to '<new name>'
Invalid datatype (field <field>, record <record>)
Invalid access (field <field>, record <record>)
Invalid type (field <field>, record <record>)
Invalid tag type (field <field>, record <record>)
Could not import tag in record <record> - unknown block name
Invalid block name '<name>' (field <field>, record <record>) could not be coerced
Invalid block name '<old name>' (field <field>, record <record>) changed to '<new>
Appendix: Creating Tag Import Files
Honeywell UDC Ethernet
Overview
Setup
Channel Properties — General
Channel Properties — Ethernet Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Tag Generation
Automatic Tag Database Generation
Device Properties — TCP/IP
Device Properties — Settings
Device Properties — Block Sizes
Data Types Description
Address Descriptions
UDC 2500 Addressing
UDC 3200 Addressing
UDC 3500 Addressing
Optimizing Your Honeywell UDC Ethernet Communications
Error Descriptions
Address '<address>' is out of range for the specified device or register
Array support is not available for the specified address: '<address>'
Bad address in block [x to y] on device '<device name>'
Bad received length [x to y] on device '<device name>'
Data Type '<type>' is not valid for device address '<address>'
Device '<device name>' block request [x to y] responded with exception <code>
Device '<device name>' is not responding.
Device address '<address>' contains a syntax error.
Device address '<address>' is not supported by model '<model name>.'
Device address '<address>' is Read Only.
Failure to initiate 'winsock.dll'
Missing address.
Unable to write to address '<address>' on device '<device>': Device responded with exception code '<code>'
Unable to write to '<address>' on device '<device name>.'
Modbus Exception Codes
Honeywell UDC Serial
Overview
Setup
Channel Properties — General
Channel Properties — Ethernet Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Settings
Device Properties — Block Sizes
Data Types Description
Honeywell UDC Serial 3000/3300 Address Descriptions
Error Descriptions
Address Validation
Missing address
Device address <address> contains a syntax error
Address <address> is out of range for the specified device or register
Data Type <type> is not valid for device address <address>
Device address <address> is Read Only
Array size is out of range for address <address>
Array support is not available for the specified address: <address>
Serial Communications
COMn does not exist
Error opening COMn
COMn is in use by another application
Unable to set comm parameters on COMn
Communications error on <channel name> [<error mask>]
Device Status Messages
Device <device name> is not responding
Unable to write to <address> on device <device name>
Honeywell UDC Serial Device Specific Messages
Bad address in block [<start address> to <end address>] on device <device name>
IDEC Serial
Overview
Setup
Channel Properties — General
Channel Properties — Serial Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Tag Generation
Automatic Tag Database Generation
Device Properties — Tag Import Settings
Data Types Description
Address Descriptions
Micro1 Addressing
Micro3 Addressing
MicroSmart Addressing
OpenNet Controller Addressing
FA2 Addressing
FA2J Addressing
FA3S-CP11 Addressing
FA3S-CP12 Addressing
Error Descriptions
Address Validation
Missing address
Device address '<address>' contains a syntax error
Address '<address>' is out of range for the specified device or register
Device address '<address>' is not supported by model '<model name>'
Data Type '<type>' is not valid for device address '<address>'
Device address '<address>' is Read Only
Serial Communications
COMn does not exist
Error opening COMn
COMn is in use by another application
Unable to set comm parameters on COMn
Communications error on '<channel name>' [<error mask>]
Device Status Messages
Device '<device name> not responding
Unable to write to '<address>' on device '<device name>'
Device Specific Messages
Bad address in block [<start address> to <end address>] on device '<device name>'
Automatic Tag Database Generation Messages
Tag '<tag name>' not imported because model does not support type
Error parsing import file record number <record number>
Import file record <record number> could not be processed due to buffer overflow
Exception encountered during tag import. Bad tag information file
Tag import failed due to low memory resources
Description truncated for import file record number <record number>
Imported tag name '<old name>' is invalid. Name changed to '<new name>'
IEC 61850 MMS Client
Overview
Setup
Channel Properties — General
Channel Properties — Ethernet Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Tag Generation
Device Properties — Automatic Configuration
Device Properties — Connection
Certificate Store
Device Properties — Communication
Device Properties — Control
Device Properties — Tag Database Settings
Data Types Description
Address Descriptions
Supported Functional Constraints
Event Log Messages
A device was added to channel <channel name> that has been set to Optimize. Since the channel has been set to optimize memory allocation, a brief loss of data may have occurred.
Error: Device <device name>, Cannot write to structured data attribute <MMS address>.
Channel initialized with insecure configuration. Devices configured with the Certificate Authentication mechanism can not connect.
<Channel name> | <MMS security error occurred. | Reason = <reason>.
<Channel name> | TLS Instance Certificate information. | Valid = Yes/No, Expired = Yes/No, Invalid signature = Yes/No, Unspecified error = Yes/No, Self-signed = Yes/No.
<Channel name> | <TLS security error occurred. | Reason = <reason>.
<Channel name> | Trust store certificate counts. | Total = <count>, Valid = <count>, Expired = <count>, Invalid signature = <count>, Unspecified error = <count>, Self-signed = <count>.
<Channel name.Device name> | <MMS security error occurred. | Reason = <reason>.
<Channel name.Device name> | <TLS security error occurred. | Reason = <reason>.
Duplicate address <tag address> produced from SCL file. Tag will not be created.
Empty trust store encountered. Channel initialized with insecure configuration. Devices configured with the Certificate Authentication Mechanism can not connect.
Error: Report control block attribute <attribute-dataset> does not reference a valid data set.
Failed to open SCL file <file path>.
Invalid address <tag address> produced from SCL file. Tag will not be created.
Error: Device <device name>, Address <MMS address>, Invalid bit string data <bit string>. Please enter a string of characters '0' and '1'.
Error: Device <device name>, Address <MMS address>, Invalid data type <data type> for data attribute.
Error: Device <device name>, Address <MMS address>, Invalid octet string data <octet string>. Please enter an even number of hexadecimal digits (for example, "00 01 C3").
Error: Device <device name>, Invalid object <MMS address>.
Error: Device <device name>, Invalid report control block address <MMS address>.
<Channel name> | MMS Instance Certificate information. | Valid = Yes/No, Expired = Yes/No, Invalid signature = Yes/No, Unspecified error = Yes/No, Self-signed = Yes/No.
No ConnectedAP of SubNetwork <SubNetwork> with IED <IED> and AccessPoint <AccessPoint> found in file <file path>.
Non-RSA private key encountered. Channel initialized with insecure configuration. Devices configured with the Certificate Authentication Mechanism cannot connect.
Selected AccessPoint <AccessPoint> not found in file <file path>.
Selected IED <IED name> not found in file <file path>.
Selected SubNetwork <SubNetwork> not found in file <file path>.
Error: Device <device name>, Structured data attribute <MMS address> cannot be applied to tag.
<Channel name.Device name> | Unable to connect. Channel is not initialized with certificates. | IP address = <IP address>.
<channel name.device name> | Unable to write to address on device. | Address = <MMS address>
IEC 60870-5-101 Client
Overview
Setup
Channel Properties — General
Channel Properties — Serial Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Channel Properties — Communication Serialization
Channel Properties — 60870 Settings
Device Properties — General
Device Properties — Scan Mode
Device Properties — Auto-Demotion
Device Properties — Time Synchronization
Device Properties — Communications
Event Playback
Timing
Data Types Description
Address Descriptions
Error Descriptions
Device failed to complete clock synchronization.
Device failed to complete counter interrogation.
Device failed to complete general interrogation.
Device <device name> failed to complete test procedure.
Device <device name> is not responding.
Error loading XML file. <Reason>.
Error loading XML file for channel. Unbalanced mode does not support a link address size of zero.
Error loading XML file for device. When the transmission mode is balanced, all devices must have the same link address. The link address of device is link address.
Error loading XML file for device. Common Address is invalid. Valid range is <low limit> to <high limit>.
Error loading XML file for device. The link address and common address pair is already in use on '<device name>'. Link and common address pairs must be unique.
Error loading XML file for device. Link Address is invalid. Valid range is <low limit> to <high limit>.
Read failed on tag.
Read failed on tag due to data type mismatch.
Reverting channel <channel name> link mode to Unbalanced Transmission. Balanced Transmission is not compatible with communication serialization or port sharing.
Too many events received in device name; the buffer has overflowed. Increase the event playback buffer size.
Unable to write to address <address> on device <device>.
Write failed on tag.
Reference Material
IEC 60870-5-101 Interoperability Guide
IEC 60870-5-104 Client
Overview
Setup
Channel Properties — General
Channel Properties — Ethernet Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Channel Properties — Communications
Channel Properties — Settings
Device Properties — General
Device Properties — Scan Mode
Device Properties — Auto-Demotion
Device Properties — Time Synchronization
Device Properties — Communications
Timing
Event Playback
Data Types Description
Address Descriptions
Error Descriptions
Device failed to complete clock synchronization.
Device failed to complete counter interrogation.
Device failed to complete general interrogation.
Device failed to complete test procedure.
Device is not responding.
Error loading XML file for device. Common address is invalid. Valid range is low limit to high limit.
Error loading XML file for device. Common Address is already used by a device.
Read failed on tag.
Read failed on tag due to data type mismatch.
Too many events received in device name; the buffer has overflowed. Increase the event playback buffer size.
Unable to write to address on device.
Write failed on tag.
IEC 60870-5-104 Interoperability Guide
Intelligent Actuator Super SEL
Overview
Setup
Channel Properties — General
Channel Properties — Serial Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Data Types Description
Address Descriptions
Super SEL Addressing
Input Port (Super SEL)
Output Port (Super SEL)
Flag (Super SEL)
Axis Status and Control
Point Data (Super SEL.
Variable
Program Execution(Super SEL)
Test Controller
Reset Controller(Super SEL)
Error Messaging
X-Sel Addressing
Input Port (X-Sel)
Output Port (X-Sel)
Flag (X-Sel)
Axis Status and Control (X-Sel)
Point Data (X-Sel.
Variable (X-Sel)
Program Execution (X-Sel.
Test Controller (X-Sel)
Reset Controller (X-Sel)
Error Messaging (X-Sel)
Event Log Messages
Address Validation
Missing Address
Device address '<address>' contains a syntax error
Address '<address>' is out of range for the specified device or register
Device address '<address>' is not supported by model '<model name>
Data Type '<type>' is not valid for device address '<address>'
Device address '<address>' is Read Only
Serial Communications
COMn does not exist
Error opening COMn
COMn is in use by another application
Unable to set comm properties on COMn
Communications error on '<channel name>' [<error mask>]
Device Status Messages
Device '<device name>' is not responding
Unable to write to '<address>' on device '<device name>
Device-Specific Messages
Bad address in block [<start address> to <end address>] on device '<device name>
InTouch Client
Overview
External Dependencies
System Configuration
Setup
Channel Properties — General
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Device Properties — Tag Generation
Device Properties — Tag Import Settings
Device Properties — Mode
Automatic Tag Database Generation
Optimizing Communications
Data Types Description
Address Descriptions
Error Descriptions
Address Validation
Missing address
Device address <address> contains a syntax error
Address <address> is out of range for the specified device or register.
Data Type <type> is not valid for device address <address>
Device address <address> is Read Only
Array size is out of range for address <address>
Array support is not available for the specified address: <address>
Device Status Messages
Device <device name> is not responding
Unable to write to <address> on device <device name>
Driver Error Messages
Low resources (OS error: <error code>)
Connection to InTouch failed. Server runtime process must be configured for interactive mode
Automatic Tag Database Generation Messages
Tag import failed (OS error: <error code>)
Tag <tag name> could not be imported due to unresolved datatype
Tag <tag name> could not be imported due to name conflict
Tag <tag name> could not be imported due to address length limitation
Imported tag name changed from <original name> to <new name>
Tag browser error
IOtech PointScan 100
Overview
Setup
Channel Properties — General
Channel Properties — Ethernet Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — TCP/IP
Device Properties — Blocks
Addressing RS-485 PointScan 200 Devices Over the Ethernet
Optimizing Communications
Data Types Description
Address Descriptions
Error Descriptions
Address Validation
Missing address
Device address '<address>' contains a syntax error
Address '<address>' is out of range for the specified device or register
Data Type '<type>' is not valid for device address '<address>'
Device address '<address>' is Read Only
Array size is out of range for address '<address>'
Array support is not available for the specified address: '<address>'
Device Status Messages
Device '<device name>' is not responding
Unable to write to '<address>' on device '<device name>'
Driver Error Messages
Winsock initialization failed (OS Error = n)
Winsock V1.1 or higher must be installed to use this device driver
Device Specific Messages
Bad address in block [<start address> to <end address>] on device '<device name>'
Block size mismatch reading [<start address> to <end address>] on device '<device name>
Block request [<start address> to <end address>] on device '<device name>.' responded with exception = n
Keyence Ethernet
Overview
Setup
Channel Properties
Channel Properties — General
Channel Properties — Ethernet Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Communication Parameters
Device Properties — Block Sizes
Data Types Description
KV Series Addressing
Event Log Messages
Event Log Messages
Device Response Error Codes
Event Log Messages
Krauss Maffei MC4 Ethernet
Overview
Setup
Channel Properties — General
Channel Properties — Ethernet Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Communications Parameters
Device Properties — Addressing Options
Data Types Description
Address Descriptions
Error Descriptions
Address Validation
Missing address
Device address <address> contains a syntax error
Data type <type> is not valid for device address <address>
Device address <address> is read only
Device Status Messages
Device <device name> is not responding
Unable to write to <address> on device <device name>
Driver Error Messages
Winsock initialization failed (OS error = n)
Winsock V1.1 or higher must be installed to use the KraussMaffei MC4 Ethernet Driver
Device <device name> detected a message size error(Tag <address>)
Device <device name> detected an invalid parameter handle in message (Tag <address>)
Device <device name> detected an invalid memory address or address can't be written (Tag <address>)
Device <device name> detected an invalid memory address (Tag <address>)
Device <device name> detected an invalid data character in message (Tag <address>)
Device <device name> detected a number of parameters error in message(Tag <address>)
Device <device name> failed to convert decimal response to a Float or Double number (Tag <address>)
Device <device name> detected a parameter size error in message (Tag <address>)
Device <device name> detected a parameter value that was too large (Tag <address>)
Device <device name> detected a parameter value that was too small (Tag <address>)
Lufkin Modbus
Overview
Setup
Channel Properties — General
Channel Properties — Serial Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Channel Properties — Communication Serialization
Device Properties — General
Device Properties — Scan Mode
Device Properties — Tag Generation
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Block Sizes
Device Properties — Data Encoding
Device Properties — Framing
Device Properties — Error Handling
Device Properties — Card Settings
Data Types Description
Address Descriptions
Statistics Items
Error Descriptions
Address Validation
Address <address> is out of range for the specified device or register.
Array size is out of range for address <address>.
Array support is not available for the specified address: <address>.
Data Type <type> is not valid for device address <address>.
Device address <address> contains a syntax error.
Device address <address> is not supported by model <model name>.
Device address <address> is read only.
Missing address
Serial Communications
COMn does not exist.
COMn is in use by another application.
Error opening COMn [OS Error == <OS Error ID>].
Serial communications error on channel <channel name> [<error mask>].
Unable to set comm parameters on COMn [OS Error == <OS Error ID>].
Device Status Messages
Device <device name> is not responding.
Unable to write to <address> on device <device name>.
Unable to write to address <address> on device <device>: Device responded with exception code <code>.
Write failed for <tag name> on device <device name>. Maximum path length of <number> exceeded.
Lufkin Modbus Specific Messages
Bad address in block [<start address> to <end address>] on device <device name>.
Bad array spanning [<address> to <address>] on device <device>.
Modbus Exception Codes
M Drivers
Memory Based
Overview
setup
Channel Properties — General
Channel Properties — Write Optimizations
Channel Properties — Advanced
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Data Types Description
Address Descriptions
Error Descriptions
Address '<address>' is out of range for the specified device or register
Array size is out of range for address <address>
Array support is not available for the specified address: <address>
Could not allocate memory for simulated device
Could not <load / save> item state data. Reason: <reason>
Data Type <type> is not valid for device address <address>
Device address <address> contains a syntax error
Device address <address> is not supported by model <model name>
Device address <address> is read only
Missing address
Mettler Toledo
Overview
Setup
Channel Properties — General
Channel Properties — Serial Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Device Properties — Tag Generation
Device Properties — Options
Data Types Description
Address Descriptions
Error Descriptions
Device address '<address>' contains a syntax error
Address '<address>' is out of range for the specified device or register
Data Type '<type>' is not valid for device address '<address>'
Device address <address> is read only
Communications error on '<channel name>' [<error mask>]
COMn does not exist
COMn is in use by another application
Error opening COMn
Unable to set comm parameters on COMn
Device '<device name>' has not sent any unsolicited updates within the currently configured data freshness tolerance period. Data associated with this device will be considered invalid
Micro-DCI
Overview
Setup
Channel Properties — General
Channel Properties — Serial Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Channel Properties — Settings
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Settings
Data Types Description
Address Descriptions
53MC1000 Addressing
53MC2000 Addressing
53MC2002 Addressing
53MC4000 Addressing
53MC5000 Addressing
Error Descriptions
Address Validation
Missing address
Device address <address> contains a syntax error
Address <address> is out of range for the specified device or register
Device address <address> is not supported by model <model name>
Data Type <type> is not valid for device address <address>
Device address <address> is Read Only
Received unexpected response for tag <address> on device <device name>
Serial Communications
COMn does not exist
Error opening COMn
COMn is in use by another application
Unable to set comm parameters on COMn
Communications error on <channel name> [<error mask>]
Device Status Messages
Device <device name> is not responding
Unable to write to <address> on device <device name>
Device Specific Messages
Bad address in block [<start address> to <end address>] on device <device name>
Mitsubishi CNC Ethernet
Overview
Setup
Channel Properties
Channel Properties — General
Channel Properties — Ethernet Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — 32-Bit Data
Device Properties — Network Parameters
Multi-Level Networks
Optimizing Communications
Data Types Description
Address Descriptions
Event Log Messages
Event Log Messages
Mitsubishi Ethernet
Overview
Setup
Channel Properties — General
Channel Properties — Ethernet Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — 32-Bit Data
Device Properties — Communications Parameters
Device Properties — Time and Date Synchronization
Multi-level Networks
Optimizing Communications
Data Types Description
Address Descriptions
Mitsubishi A Series Address Descriptions
Mitsubishi FX3U Series Address Descriptions
Mitsubishi L Series Address Descriptions
Mitsubishi Q Series Address Descriptions
Mitsubishi iQ-R Series Address Descriptions
Mitsubishi iQ-F Series Address Descriptions
Mitsubishi QnA Series Address Descriptions
Event Log Messages
Event Log Messages
PLC Setup
A Series PLC Setup
FX3U Series PLC Setup
L Series PLC Setup
L Series Built-in Ethernet Port PLC Setup
QnA Series PLC Setup
Q Series PLC Setup
Q Series PLC Setup
Q Series PLC Setup
Q Series Built-in Ethernet Port PLC Setup
Mitsubishi Ethernet Driver for Edge
Overview
Setup
Channel Properties — General
Channel Properties — Ethernet Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Device Properties — Auto-Demotion
Device Properties — Timing
Device Properties — 32-Bit Data
Device Properties — Communications Parameters
Device Properties — Time and Date Synchronization
Multi-level Networks
Optimizing Your Mitsubishi Ethernet Communications
Data Types Description
Address Descriptions
Mitsubishi A Series Address Descriptions
Mitsubishi FX3U Series Address Descriptions
Mitsubishi L Series Address Descriptions
Mitsubishi Q Series Address Descriptions
Mitsubishi iQ-R Series Address Descriptions
Mitsubishi iQ-F Series Address Descriptions
Mitsubishi QnA Series Address Descriptions
Event Log Messages
Event Log Messages
PLC Setup
A Series PLC Setup
FX3U Series PLC Setup
L Series PLC Setup
L Series Built-in Ethernet Port PLC Setup
QnA Series PLC Setup
Q Series PLC Setup
iQ-R Series PLC Setup
iQ-F Series PLC Setup
Q Series Built-in Ethernet Port PLC Setup
Mitsubishi FX
Overview
Setup
Data Types Description
Address Descriptions
FX Addressing
FX0 Addressing
FX0N Addressing
FX2N Addressing
FX3U Addressing
Event Log Messages
Event Log Messages
Error Mask Definitions
Appendix: Ethernet Encapsulation Examples
Mitsubishi FX Net
Overview
Setup
PLC Parameter Settings
Data Types Description
Address Descriptions
FX Addressing
FX2C Addressing
FX0N Addressing
FX2N Addressing
FX3U Addressing
FXOpen Addressing
Event Log Messages
Event Log Messages
Error Mask Definitions
Mitsubishi Serial
Overview
Setup
Channel Properties
Channel Properties — General
Channel Properties — Serial Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties
Device Properties — Identification
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Bridging
Device Properties — 32-Bit Data
Multi-Level Networks
Data Types Description
Address Descriptions
A Series Address Descriptions
Q Series Address Descriptions
Event Log Messages
Event Log Messages
Error Mask Definitions
Appendix: PLC Setup
A1SJ71C24-R2 Settings and Diagrams
A1SJ71C24-R4 Settings and Diagrams
AJ71C24-S8 Setting and Diagrams
QJ71C24N Configuration
Modbus ASCII Serial
Overview
Setup
Channel Setup
Channel Properties — General
Channel Properties — Serial Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Channel Properties — Communication Serialization
Device Setup
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Tag Generation
Device Properties — Block Sizes
Device Properties — Variable Import Settings
Device Properties — Settings
Device Properties — Error Handling
Automatic Tag Database Generation
Data Types Description
Address Descriptions
Modbus ASCII Addressing
Function Codes Description
Flow Computer Addressing
Flow Automation Addressing
Event Log Messages
Event Log Messages
Modbus Exception Codes
Error Mask Definitions
Modbus Plus
Overview
External Dependencies
Setup
Channel Properties
Channel Properties — General
Channel Properties — Write Optimizations
Channel Properties — Advanced
Channel Properties — Adapter
Device Properties
Device Properties — General
Device ID
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Tag Generation
Device Properties — Block Sizes
Device Properties — Variable Import Settings
Device Properties — Settings
Automatic Tag Database Generation
Optimizing Communications
Data Types Description
Address Descriptions
Modbus Addressing
Function Codes Description
Configuring the Device for Global Data Communications
Event Log Messages
Event Log Messages
Modbus Exception Codes
Modbus RTU Serial
Overview
Setup
Channel Properties — General
Channel Properties — Communication Serialization
Channel Properties — Write Optimizations
Channel Properties — Serial Communications
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Device Properties — Ethernet Encapsulation
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Tag Generation
Device Properties — Settings
Device Properties — Block Sizes
Device Properties — Variable Import Settings
Device Properties — Framing
Device Properties — Error Handling
Automatic Tag Database Generation
Statistics Items
Data Types Description
Address Descriptions
Modbus Addressing
Magnetek GPD 515 Drive Addressing
Elliott Flow Computer Addressing
Daniels S500 Flow Computer Addressing
Dynamic Fluid Meter Addressing
Omni Flow Computer Addressing
Omni Custom Packets
Omni Raw Data Archive
Omni Text Reports
Omni Text Archive
Function Codes Description
Using API Commands
Configuration API Service — Channel Properties
Configuration API Service — Device Properties
Event Log Messages
Event Log Messages
Error Mask Definitions
Modbus Exception Codes
Modbus Server Serial
Overview
Setup
Channel Properties — General
Channel Properties — Serial Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Channel Properties — Timing
Device Properties — General
Device Properties — Scan Mode
Device Properties — Memory
Memory Addressing
Data Types Description
Address Descriptions
Modbus Addressing
Daniels/Enron Addressing
Event Log Messages
Event Log Messages
Error Mask Definitions
Modbus Exception Codes
Modbus TCP/IP Ethernet
Overview
Supported Device Models
Setup
Channel Properties — General
Channel Properties — Ethernet Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Channel Properties — Communication Serialization
Channel Properties — Ethernet
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Tag Generation
Device Properties — Variable Import Settings
Device Properties — Unsolicited
Modbus Client & Server Considerations
Device Properties — Error Handling
Device Properties — Ethernet
Device Properties — Settings
Device Properties — Block Sizes
Configuration API Modbus Example
Enumerations
Device Model Enumerations
Automatic Tag Database Generation
Importing from Custom Applications
Optimizing Modbus Ethernet Communications
Data Types Description
Address Descriptions
Driver System Tag Addresses
Function Codes Description
Applicom Addressing
Generic Modbus Addressing
TSX Quantum
TSX Premium
CEG Addressing
Fluenta Addressing
Instromet Addressing
Mailbox Addressing
Modbus Addressing
Roxar Addressing
Statistics Items
Event Log Messages
Event Log Messages
Modbus Exception Codes
Appendix A — Channel Properties
Appendix B — Device Properties
Appendix C — Tag Properties
Modbus TCP/IP Ethernet for Edge
Overview
Setup
Supported Device Models
Properties
Channel Properties — General
Channel Properties — Ethernet Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Channel Properties — Communication Serialization
Channel Properties — Ethernet
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Tag Generation
Device Properties — Variable Import Settings
Device Properties — Error Handling
Device Properties — Ethernet
Device Properties — Settings
Device Properties — Block Sizes
Configuration API Modbus Example
Enumerations
Device Model Enumerations
Automatic Tag Database Generation
Importing from Custom Applications
Optimizing Modbus Ethernet Communications
Data Types Description
Address Descriptions
Driver System Tag Addresses
Function Codes Description
Modbus Addressing
Statistics Items
Event Log Messages
Event Log Messages
Modbus Exception Codes
Appendix A — Channel Properties
Appendix B — Device Properties
Appendix C — Tag Properties
MQTT Client
Overview
Setup
Channel Properties — General
Channel Properties — Advanced
Channel Properties — MQTT Server
Channel Properties — Timing
Device Properties — General
Device Properties — Scan Mode
Device Properties — Tag Generation
Data Types Supported through Automatic Tag Generation
Data Types Description
Timestamp Behavior
Quality Behavior
Tag Address Descriptions
Appendix — Tag Addressing Examples
Event Log Messages
Event Log Messages
Unable to generate a tag database for '<channel>'.'<device>': <Reason>
MTConnect
Overview
Setup
Channel Properties — General
Channel Properties — Ethernet Communications
Channel Properties — Advanced
Channel Properties — Write Optimizations
Device Discovery Procedure
Device Discovery Settings
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Tag Generation
Device Properties — Communications
Automatic Tag Database Generation
Data Types Description
Address Descriptions
Error Descriptions
Address Validation
Data Type <type> is not valid for device address <address>.
Device address <address> contains a syntax error.
Device address <address> is read only.
Automatic Tag Database Generation Messages
Unable to generate a tag database for device <device>. Reason: Agent did not respond.
Unable to generate a tag database for device <device>. Reason: Agent returned MTConnect error: <error-string>.
Unable to generate a tag database for device <device>. Reason: Error in creating MTConnect packet.
Unable to generate a tag database for device <device>. Reason: HTTP error: <error-code>.
Unable to generate a tag database for device <device>. Reason: Internal error.
Unable to generate a tag database for device <device>. Reason: Invalid response from agent.
Unable to generate a tag database for device <device>. Reason: Response from agent failed schema validation.
Unable to generate a tag database for device <device>. Reason: Unable to connect to the agent.
Unable to generate a tag database for device <device>. Reason: Unable to transmit request to the agent.
Current Update Mode Command Messages
<channel name>.<device name> | Device is not responding. | ID = <ID>
Read for the data item <address> on device <device> failed. Reason: Agent reported data is UNAVAILABLE.
Read for the data item <address> on device <device> failed. Reason: Response from agent failed schema validation.
Read for the data items <address> on device <device> failed. Reason: Error in creating MTConnect packet.
Read for the data items <address> on device <device> failed. Reason: Internal error.
Read for the data items <address> on device <device> failed. Reason: Invalid data item ID.
Read for the data items <address> on device <device> failed. Reason: Invalid response from agent.
Read for the data items <address> on device <device> failed. Reason: Received HTTP error <error-code>.
Read for the data items <address> on device <device> failed. Reason: Received MTConnect error <error-string>.
Read for the data items <address> on device <device> failed. Reason: Unable to connect to the agent.
Read for the data items <address> on device <device> failed. Reason: Unable to transmit request to the agent.
Read for the data items <address> on device <device> failed. Reason: XML Validation Error: The node is neither valid nor invalid because no DTD / schema declaration was found.
<schema file> failed to load/; may cause validation errors.
Unable to bind to adapter: <network adapter name>. Connect failed.
Sample Update Mode Command
<channel name>.<device name> | Device is not responding. | ID = <ID>
Sample update mode failure. | Context = <Request>, Reason = Received HTTP error: <error-code>.
Sample update mode failure. | Context = <Request>, Reason = Internal error.
Sample update mode failure. | Context = <Request>, Reason = Invalid response from agent.
Sample update mode failure. | Context = <Request>, Reason = Received MTConnect error: <error-string>.
Sample update mode failure. | Context = <Request>, Reason = Schema validation error: <error-string>.
Sample update mode failure. | Context = <Request>, Reason = Unable to connect to the agent.
Sample update mode failure. | Context = <Request>, Reason = Unable to transmit request to the agent.
MTConnect Error Codes
HTTP Response Codes
O-P Drivers
ODBC Client
Overview
External Dependencies
Setup
Channel Properties — General
Channel Properties — Write Optimizations
Channel Properties — Advanced
Channel Properties — Data Source Settings
Data Source Authentication
Device Properties — General
Device Properties — Tag Generation
Device Properties — Data Source Access Method
Fixed Table
Table Selection
Automatic Tag Generation Options
Timing Options — Fixed
Dynamic Tables
Table Selection
Automatic Tag Generation Options
Timing Options — Dynamic
Query
Building a Valid Query Statement
Miscellaneous Query Trigger Definition
Timing Options — Query
Automatic Tag Generation Options
Using the Query Access Method
Data Source Query Format
Modifying a Query Statement
Stored Procedure
Creating the Tag Database
Selecting a Different Stored Procedure
Choosing between the Query or the Stored Procedure Access Method for Stored Procedure Execution
Running as a System Service
Connecting Remotely in System Service Mode
Data Types Description
Address Descriptions
Error Descriptions
Address Validation
Missing address.
Device address <address> contains a syntax error.
Data Type <type> is not valid for device address <address>.
Device address <address> is read only.
Device Status Messages
Write request rejected on read only item reference <channel name><device name><address>.
ODBC Client Driver Specific Messages
Call to execute stored procedure <stored procedure name> on device <device name> failed. (Reason: ODBC Specific Error).
Data source <data source name> is configured as Read Only (all writes will be rejected).
Query validation failed due to the following: (Reason: ODBC Specific Error).
Unable to retrieve table names. (Reason: ODBC Specific Error).
Unable to retrieve table column names. (Reason: ODBC Specific Error).
Unable to retrieve table row count. (Reason: ODBC Specific Error).
Unable to retrieve stored procedure names. (Reason: ODBC Specific Error).
Unable to retrieve supported access methods. (Reason: ODBC Specific Error).
Unable to connect to data source on channel <channel name>. (Reason: ODBC Specific Error).
Unable to open recordset on device <device name>. (Reason: ODBC Specific Error).
Unable to query recordset on device <device name>. (Reason: ODBC Specific Error).
Unable to retrieve database value for tag <tag address> on device <device name>.
Unable to write database value <value> for tag <tag address> on device <device.
Unable to read internal tag <tag address> on device <device name>. (Reason: ODBC Specific Error).
Unable to write to internal tag <tag address> on device <device name> (Reason: ODBC Specific Error).
Unable to read parameter tag <tag address>. (Reason: ODBC Specific Error).
Unable to write to parameter tag <tag address> (Reason: ODBC Specific Error).
Unable to execute stored procedure '<stored procedure name> on device <device. (Reason: ODBC Specific Error).
Unable to write to item <tag address> (Reason: ODBC Specific Error).
OMNI Flow Computer
Overview
Setup
Channel Properties — General
Channel Properties — Serial Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Channel Properties — Communication Serialization
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Time Synchronization
Device Properties — Data Access
Device Properties — Block Sizes
Device Properties — Framing and Error Handling
Device Properties — EFM Meters
EFM Cache
Meter Properties — General
Meter Properties — Configuration
EFM Mapping
EFM Alarm Mapping
EFM Event Mapping
EFM History Mapping
EFM History Mapping — Gas Models
EFM History Mapping — Liquid Models
CSV Import/Export
Data Types Descriptions
Address Descriptions
Error Descriptions
Address Validation
Address '<address>' is out of range for the specified device or register
Array size is out of range for address '<address>'
Array support is not available for the specified address: '<address>'
Data Type '<type>' is not valid for device address '<address>'
Device address '<address>' contains a syntax error
Device address '<address>' is not supported by model '<model name>'
Device address '<address>' is Read Only
Missing address
Received block length of '<received length>' does not match expected length of '<expected length>' for address '<address>' on device '<device>'
Device Status Messages
Device '<device name>' is not responding
Unable to write to '<address>' on device '<device name>'
Unable to write to address '<address>' on device '<device>': Device responded with exception code '<code>'
Write failed for '<tag name>' on device '<device name>'. Maximum path length of '<number>'
OMNI Flow Computer Specific Messages
'<device name>' - A starting address of '<address>' in the archive’s record structure is invalid. May not receive data for address '<address>'
'<device name>' - Alarm record parse for device failed
'<device name>' - Archive '<archive number>' is not configured correctly for address '<address>'. Max number of records is zero
'<device name>' - Archive record contains an invalid address. BOOL, 8-byte strings, and 16-byte strings are not supported
'<device name>' - Archive record for address '<address>' contains an unexpected number of bytes. Expected '<number of bytes>' bytes, received '<number of bytes>' bytes
'<device name>' - Config data attribute for meter tap location read from device address '<address>' is '<value>', and does not map to any valid meter tap locations. Expecting 0 for flange, or 1 for pipe. Defaulting to flange
'<device name>' - Config data attribute for meter type read from device address '<address>' is '<value>', and does not map to any valid meter types. Expected values are 0, 2, or 3 for orifice, 1 for turbine, 4 or 8 for ultra sonic, 5 for vcone, and 9 for coriolis.
<device name>' - Config data attribute for static pressure tap read from device address '<address>' is '<value>', and does not map to any valid static pressure tap locations. Expecting 0 for up, or 1 for down. Defaulting to up
'<device name>' - Config data attribute for static pressure unit read from device address '<address>' is '<value>', and does not map to a valid pressure unit. Expecting 0 for kPa, 1 for Bar, or 2 for kg/cm2. Defaulting to kPa
'<device name>' - Config data attribute for totalizer digits read from the device address '<address>' is '<value>', and does not map to a valid number of totalizer digits. Expecting 0 for 9 digits, or 1 for 8 digits. Defaulting to 9 digits
'<device name>' - Date format for address '<address>' is invalid. Device returned '<value>', valid values are 0 or 1
'<device name>' - Device Firmware version '<Firmware version>' is not supported by the '<model name>' model
'<device name>' - Device password write not successful. Value in response is different from the written value
'<device name>' - Event record parse for device failed
'<device name>' - Failed to read EFM pointer file. <Extended Error>
'<device name>' - Failed to write EFM pointer file. <Extended Error>
'<device name>' - Meter and shared archives are not in sync. Records will only contain flow data (no analysis)
'<device name>' - Meter archive record parse failed
'<device name>' - Read invalid Firmware version '<Firmware version>' from address '<address>', config upload complete
'<device name>' – Read phase of time sync not successful. Value in response is different from the written value.
'<device name>' - Shared '<archive type>' archive address is not configured, records will only contain flow data (no analysis)
'<device name>' - Shared archive record parse failed
'<device name>' - The <archive type> mapping contains more configured attributes than the device. Some attributes will not contain valid data
'<device name>' - The max alarm archive size was changed from '<previous size>' to '<current size>'
'<device name>' - The max event archive size was changed from '<previous size>' to '<current size>'
'<device name>' - Time sync write not successful. Value in response is different from the written value
'<device name>' - Unable to read '<number of registers>' registers in config register block at address '<address>'
'<device name>' - Unable to read date format register for address '<address>'. Response is not the correct size
'<device name>' - Unable to read index registers. Response is not the correct size
'<device name>' - Unable to read record format registers for address '<address>'. Response is not the correct size
'<device name>' - Unable to write requested record register for address '<address>'. Wrote '<value>', read back '<value>'
'<device name>' - Unable to write requested record register for address '<address>'. Response is not the correct size
Alarm mapping for address '<address>' is invalid and will be ignored
Alarm state for address '<address>' is invalid. Setting the state to <state>
Alarm type for address '<address>' is invalid. Setting the type to <type>
Bad address in block [<start address> to <end address>] on device '<device name>'
Bad array spanning [<address> to <address>] on device '<device>'
Device password invalid for device '<device name>'
Device password write for device '<device name>' was successful
History attribute '<attribute index>' is unknown and will be ignored
History mapping for attribute '<attribute name>' is invalid and will be ignored
Received 'needs password' exception from device '<device name>' with 'fail after successive timeouts' set to 1. Set the 'fail after successive timeouts' setting to a value greater than 1 and verify that the 'device password' setting is correct
Serialization of EFM data to temporary file '<file name>' failed. Reason: '<file I/O error>'
The '<archive type>' archive number for meter '<meter name>' is already being used. XML project load not successful
The shared '<archive type>' archive number is already in use by another meter. XML project load not successful
Unable to read '<address>' from device '<device name>'. The device is configured for broadcast writes only
Unable to read block address ['<start address>' to '<end address>'] on device '<device name>'. Unexpected characters in response
Warning loading '<mapping type>' mapping from CSV. '<warning type>'
Serial Communications
Communications error on '<channel name>' [<error mask>]
COMn does not exist
COMn is in use by another application
Error opening COMn
Unable to set comm parameters on COMn
Modbus Exception Codes
Omron FINS Ethernet
Overview
Setup
Channel Properties
Channel Properties — General
Channel Properties — Ethernet Communications
Channel Properties — Write Optimizations
Channel Properties — Communications Parameters
Channel Properties — Advanced
Device Properties
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — FINS Network Configuration
Device Properties — Run Mode Settings
Device Properties — Communications Parameters
FINS Networks
Multihoming
Data Types Description
Address Descriptions
C200H Addressing
C500 Addressing
C1000H Addressing
C2000H Addressing
CV500 Addressing
CV1000 Addressing
CV2000 Addressing
CVM1-CPU01 Addressing
CVM1-CPU11 Addressing
CVM1-CPU21 Addressing
CS1 Addressing
CJ1 Addressing
CJ2 Addressing
Event Log Messages
Main and Sub Error Codes
Remote Network Error
Omron FINS Serial
Overview
Setup
FINS Networks
Data Types Description
Address Descriptions
C200H Addressing
C500 Addressing
C1000H Addressing
C2000H Addressing
CV500 Addressing
CV1000 Addressing
CV2000 Addressing
CVM1-CPU01 Addressing
CVM1-CPU11 Addressing
CVM1-CPU21 Addressing
CS1 Addressing
CJ1 Addressing
CJ2 Addressing
Event Log Messages
Event Log Messages
Error Mask Definitions
Main and Sub Error Codes
Omron Host Link
Overview
Setup
Channel Properties — General
Channel Properties — Serial Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Inter-Character Delay
Data Types Description
Address Descriptions
C20H Addressing
C200H Addressing
CQM1 Addressing
Open Addressing
Event Log Messages
Error Mask Definitions
Omron NJ Ethernet
Overview
Setup
Communications Routing and Timing
Connection Path Specification
Routing Examples
Channel Properties — General
Channel Properties — Ethernet Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Tag Generation
Device Properties — Communications Parameters
Device Properties — Options
Optimizing Communications
Optimizing the Application
Performance Statistics and Tuning
Data Types Description
Address Descriptions
Address Formats
Tag Scope
Predefined Term Tags
Automatic Tag Database Generation
Tag Hierarchy
Event Log Messages
Event Log Messages
Error Codes
Encapsulation Error Codes
CIP Error Codes
0x01 Extended Error Codes
0x0C Extended Error Codes
0x1F Extended Error Codes
0x20 Extended Error Codes
Omron Process Suite
Overview
Setup
Channel Properties — General
Channel Properties — Serial Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Data Types Description
Address Descriptions
E5AF-A Address Description
E5AF-AH Address Description
E5AJ-A Address Description
E5AX-A Address Description
E5AX-AH Address Description
E5AX-DAA Address Description
E5AX-PRR Address Description
E5AX-VAA Address Description
E5CN-PT Address Description
E5CN-TC Address Description
E5EJ-A Address Description
E5GN-PT Address Description
E5GN-TC Address Description
Event Log Messages
Event Log Messages
Error Mask Definitions
Omron Toolbus
Overview
Setup
Channel Properties — General
Channel Properties — Serial Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Communication Parameters
Data Types Description
CS1/CJ1 Address Descriptions
Event Log Messages
Event Log Messages
Error Mask Definitions
OPC DA Client
Overview
OPC Compliance
Project Architecture
Setup
Channel Properties — General
Channel Properties — Write Optimizations
Channel Properties — Advanced
Channel Properties — OPC Server
Channel Properties — Connection
Device Properties — General
Device Properties — Scan Mode
Device Properties — OPC Group
Device Properties — Communications Parameters
Device Properties — Watchdog
Watchdog Callback Monitoring
Device Properties — Import
Data Types Description
Address Descriptions
Error Descriptions
Add item failed for <item> on device <device>. Function error: <error code>.
Add item failed for <item>on device <device>s. Item error: <error code>.
Add watchdog item failed for <item> on device <device>. Item error: <error code>. <error description>.
Async Write 1.0 failed for <item> on device <device>. Callback item error: <error code>.
Async Write 1.0 failed for <item> on device <device>. Function error: <error code>.
Async Write 1.0 failed for <item> on device <device>. Item error: <error code>.
Async Write 2.0 failed for <item> on device <device>. Callback item error: <error code>.
Async Write 2.0 failed for <item> on device <device>. Function error: <error code>.
Async Write 2.0 failed for <item> on device <device>. Item error: <error code>.
Failed to acquire item management interface for device <device>.
Failed to add group for device <device>. Reason: <error code>.
Failed to connect to server on channel <channel>.
Failed to establish callback for device <device>.
Reconnecting server on channel <channel> due to GetStatus failure.
Reconnecting server on channel <channel> due to shutdown notification.
Reconnecting server on channel <channel> due to watchdog failure on device <device>.
Tag <tag item> on device <device> was not imported. Item failed OPC server validation.
Unknown data type for tag <item> on device <device>. Using default.
Appendix
OPC UA Client
Overview
Profiles
Supported OPC UA Server Profiles
Tunneling
Certificate Model
Re-establishing Connections
Setup
Channel Properties — General
Channel Properties — Write Optimizations
Channel Properties — Advanced
Channel Properties — UA Server
Channel Properties — UA ServerBrowser
Channel Properties — UA Session
Channel Properties — Authentication
Device Properties — General
Device Properties — Scan Mode
Device Properties — Subscription
Device Properties — Communications Parameters
Device Properties — Connection
Device Properties — Monitored Items
Device Properties — Tag Generation
Address Descriptions
Data Types Description
OPC UA Data Types
Event Log Messages
Error Descriptions
Event Log Messages
Message Boxes
Error encountered during import item browse. Server <server> may have stopped running.
Items on this page may not be changed while the driver is processing tags.
The Lifetime Count must be a minimum of three times the Max. Keep Alive Count (Lifetime Count = <count>).
Please enter a username.
Explanations
Cannot connect to the server.
The client certificate has expired. Please use the OPC UA Configuration manager to create a new certificate.
The client certificate is invalid. Please use the OPC UA Configuration Manager to update the client certificate.
The server certificate is revoked. Please use the OPC UA Configuration Manager to update the certificate.
The server certificate is untrusted. Please use the OPC UA Configuration Manager to add the certificate to the client's trusted store.
Timeout trying to perform the operation.
OPC UA Client Driver for Edge
Overview
Profiles
Supported OPC UA Server Profiles
Tunneling
Certificate Model
Re-establishing Connections
Setup
Channel Properties — General
Channel Properties — Write Optimizations
Channel Properties — Advanced
Channel Properties — UA Server
Channel Properties — UA Session
Channel Properties — Authentication
Device Properties — General
Device Properties — Scan Mode
Device Properties — Subscription
Device Properties — Communications Parameters
Device Properties — Connection
Device Properties — Monitored Items
Data Types Description
OPC UA Data Types
Address Descriptions
Event Log Messages
Error Descriptions
Event Log Messages
Message Boxes
Error encountered during import item browse. Server <server> may have stopped running.
Items on this page may not be changed while the driver is processing tags.
The Lifetime Count must be a minimum of three times the Max. Keep Alive Count (Lifetime Count = <count>).
Please enter a username.
Explanations
Cannot connect to the server.
The client certificate has expired. Please create a new certificate.
The client certificate is invalid. Please update the client certificate.
The server certificate is revoked. Update the certificate.
The server certificate is untrusted. Add the certificate to the client's trusted store.
Timeout trying to perform the operation.
OPC XML-DA Client
Overview
Project Architecture
Setup
Channel Properties — General
Channel Properties — Write Optimizations
Channel Properties — Advanced
Channel Properties — OPC Server
Channel Properties — HTTP Proxy
Channel Properties — HTTP Authentication
Device Properties — General
Device Properties — Scan Mode
Device Properties — Exception Mode Options
Device Properties — Communications Parameters
Device Properties — Import
Data Types Description
Address Descriptions
Error Descriptions
Access is denied for item <address>
An invalid subscription handle was passed to the server on <channel/device name>
Invalid continuation point
Invalid filter
Invalid hold time for item <address>
Invalid item name for item <address>
Invalid path for item <address> with path <path>
Item <address> is Write Only
General SOAP fault on <channel/device name>
Server is busy on <channel/device>
Server is in an abnormal state on <channel/device name>
SOAP data queue overflow
SOAP HTTP communication error on <channel/device name>
SOAP SSL authentication error on <channel/device name>
SOAP TCP communication error on <channel/device name>
SOAP XML parse error on <channel/device name>
The data type cannot be accepted for item <address>
The item name <Channel>.<Device>.<Item Path>.<Item Name> is no longer available in the server address space
The item path <Channel>.<Device>.<Item Path> is no longer available in the server address space
The Property ID is invalid for the item <address>
The server reported an unspecified failure on <channel/device>
The server reported that the operation timed out on <channel/device name>
The server returned a "Not Supported" error on item <address>
The server returned an "Out of memory" error on <channel/device name>
The specified write value for <address> is out of range
Unknown data type for tag <item> on device <device>. Using Default
Best Practices
Time-Sensitive Data Acquisition
Optimation OptiLogic
Overview
Setup
Channel Properties — General
Channel Properties — Ethernet Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Tag Generation
Optimizing Optimation OptiLogic Communications
Data Types Description
Address Descriptions
Digital I/O Bit Mapping
Module By Classification
Digital Input Modules
4 Digital Input Module
8 Digital Input Module
16 Digital Input Module
24 Digital Input Module
32 Digital Input Module
Digital Output Modules
4 Digital Output Module
8 Digital Output Module
16 Digital Output Module
24 Digital Output Module
32 Digital Output Module
Analog Input Modules
2-Channel Analog Input Module
4-Channel Analog Input Module
8 Channel Analog Input Module
16-Channel Analog Input Module
Analog Output Modules
2-Channel Analog Output Module
4-Channel Analog Output Module
8 Channel Analog Output Module
16-Channel Analog Output Module
Specialty Modules
High-Speed Counter Module
2-Channel High-Speed Counter Module
Base RS232 Port
Dual RS232 Port Module
Operator Panels
OL3406 Operator Panel
OL3420 Operator Panel
OL3440 Operator Panel
OL3850 Operator Panel
Module By SubType
4 Digital Output Module
8 Digital Output Module
8 Digital Output Module
8 Digital Output Module
8 Digital Input Module
4 Digital Input Module
8 Digital Input Module
8 Digital Input Module
2-Channel High-Speed Counter Module
High-Speed Counter Module
4-Channel Analog Output Module
8 Channel Analog Input Module
8 Channel Analog Input Module
Dual RS232 Port Module
OL3406 Operator Panel
OL3420 Operator Panel
OL3440 Operator Panel
OL3850 Operator Panel
Base RS232 Port
Error Descriptions
OptiLogic Device Error Codes
Driver Error Messages
Winsock initialization failed (OS Error = n)
Winsock V1.1 or higher must be installed to use the OptiLogic device driver
Memory allocation error
Driver Warning Messages
Device '<device name>' is not responding
Device address <address> contains a syntax error
Address <address> is out of range for the specified device or register
Device address <address> is not supported by model <model name>
Device address <address> is Read Only
Array size is out of range for address <address>
Array support is not available for the specified address: <address>
Data type <type> is not valid for device address <address>
Base with type <type> Major ver. <major> Minor ver. <minor> is currently not supported. Contact technical support
Module in slot <slot> with type <type> subtype <subtype> is currently not supported. Contact Technical Support
Panel with type <type> subtype <subtype> is currently not supported. Contact Technical Support
Read Errors
Frame received from device <device name> contains errors
Base module referenced in address <address> on device <device name> does not exist
Slot module referenced in address <address> on device <device name> does not exist
Panel module referenced in address <address> on device <device name> does not exist
Address <address> contains an invalid address type for RTU module, device <device name>
Address <address> contains an invalid address type for module <subtype>, slot <slot>, device <device name>
Address <address> contains an invalid address type for panel module <subtype>, device <device name>
Address <address> is out of range for module <subtype> in slot <slot>, device <device name>
Address <address> is out of range for panel module <subtype>, device <device name>
Port <port> of the base module returned an error with value=<error value>
Module <subtype> in slot <slot> returned an error with value =<error value>
Port <port> of module <subtype> in slot <slot> returned an error with value=<error value>
Panel module <subtype> returned an error with value=<error value>
Write Errors
Unable to write to <address> on device <device name>
Write failed. Frame received from device <device name> contains errors
Write rejected. Base module referenced in address <address> on device <device name> does not exist
Write rejected. Slot module referenced in address <address> on device <device name> does not exist
Write rejected. Panel module referenced in address <address> on device <device name> does not exist
Write rejected. Address <address> contains an invalid address type for RTU module, device <device name>
Write rejected. Address <address> contains an invalid address type for module <subtype>, slot <slot>, device name
Write rejected. Address <address> contains an invalid address type for panel module <subtype>, device <device name>
Write rejected. Address <address> is out of range for module <subtype> in slot <slot>, device <device name>
Write rejected. Address <address> is out of range for panel module <subtype>, device <device name>
Write failed. Port <port> of the base module returned an error with value=<error value>
Write failed. Module <subtype> in slot <slot> returned an error with value=<error value>
Write failed. Port <port> of module <subtype> in slot <slot> returned an error with value=<error value>
Write failed. Panel module <subtype> returned an error with value=<error value>
Opto 22 Ethernet
Overview
Setup
Channel Properties — General
Channel Properties — Ethernet Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Tag Generation
Device Properties — Communications Parameters
Device Properties — Import
Data Types Description
Address Descriptions
Automatic Tag Database Generation
Optimizing Opto 22 Ethernet Communications
Error Descriptions
Address Validation
Missing address
Device address '<address>' contains a syntax error
Address '<address>' is out of range for the specified device or register
Device address '<address>' is not supported by model '<model name>'
Array support is not available for the specified address: '<address>'
Data Type '<type>' is not valid for device address '<address>'
Device address '<address>' is Read Only
Device Status Messages
Device '<channel.device>' not responding to requests on I/O Unit (MMIO) port
Device '<channel.device>' not responding to requests on Control Engine (CONT) port
Unable to write to '<address>' on device '<device>'
Device Specific Messages
Winsock initialization failed (OS Error = <n>)
Winsock V1.1 or higher must be installed to use the Opto 22 Ethernet device driver
Unable to bind to adapter: '<adapter name>'. Connect failed
Powerup clear failed for device'<device name>'. <Protocol> response code: <n>
Write failed for tag '<tag name>' on device '<device name>'. <Protocol> response code: <n>
Read failed for tag '<tag name>' on device '<device name>'. <Protocol> response code: <n>
Block read failed for <n> bytes starting at <memory map offset> on device '<device name>'. <Protocol> response code: <n>
Read failed for tag '<tag name>' on device '<device name>'. Object appears to be invalid in current strategy
Read failed for tag '<tag name>' on device '<device name>'. Unexpected CONT data format
Read request failed for multiple tags on device '<device name>'. CONT response code: <n>
Import Error Messages
Did not import one or more items with incompatible protocol or IP
No compatible items found in import file
Did not import item '<address>' at record <record> - arrays not supported for specified address
Did not import item '<address>' at record <record> - Read and Clear tags must be manually created
Error parsing import file record number n, field f
Did not import item '<address>' at record <record> - unsupported array size
Response Codes
MMIO Response Codes
CONT Response Codes
Partlow ASCII
Overview
Setup
Channel Properties — General
Channel Properties — Serial Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Data Types Description
Address Descriptions
Error Descriptions
Address Validation
Missing address
Device address '<address>' contains a syntax error
Address '<address>' is out of range for the specified device or register
Device address '<address>' is not supported by model '<model name>.'
Data Type '<type>' is not valid for device address '<address>'
Device address '<address>' is Read Only
Serial Communications
COMn does not exist
Error opening COMn
COMn is in use by another application
Unable to set comm parameters on COMn
Communications error on '<channel name>' [<error mask>]
Device Status Messages
Device '<device name>' is not responding
Unable to write to '<address>' on device '<device name>.'
Device Specific Messages
Read request rejected for Tag '<tag address>' on device '<device name'>. Deactivating Tag
Write request rejected for tag '<tag address>' on device '<device name>'
Philips P8/PC20
Overview
Setup
Channel Properties — General
Channel Properties — Serial Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Data Types Description
Address Descriptions
PC20 Addressing
P8 Addressing
Error Descriptions
Address Validation
Missing address
Device address '<address>' contains a syntax error
Address '<address>' is out of range for the specified device or register
Device address '<address>' is not supported by model '<model name>'
Data Type '<type>' is not valid for device address '<address>'
Device address '<address>' is Read Only
Serial Communications
COMn does not exist
Error opening COMn
COMn is in use by another application
Unable to set comm parameters on COMn
Communications error on '<channel name>' [<error mask>]
Device Status Messages
Device '<device name>' is not responding
Unable to write to '<address>' on device '<device name>'
Ping
Overview
Setup
Channel Properties — General
Channel Properties — Ethernet Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Tag Generation
Channel Setup
Device Discovery Procedure
Data Types Description
Address Descriptions
Error Descriptions
Device <address> is not responding
Device Discovery has exceeded <max devices> maximum allowed devices
The Device ID for <address> could not be resolved
Required functionality of icmp.dll is not found
Unable to bind to adapter: <adapter>. Connect failed
Unable to generate a tag database for device <device name>. Reason: Could not generate tags due to low system resources
Unable to load required file <file>. This driver will not be operational
Winsock initialization failed (OS Error = <error>)
Winsock shut down failed (OS Error = <error>)
Winsock V1.1 or higher must be installed to use the Ping Driver
S Drivers
SattBus Ethernet
Overview
Setup
Channel Properties — General
Channel Properties — Ethernet Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Communication Properties
Changing the Local Port Number and Network Adapter Properties
Device Properties — Settings
Bit Ordering for Memory Cells
Data Types Description
Address Descriptions
Overlapped vs. None-Overlapped Addressing
Error Descriptions
Address Validation
Address is out of range for the specified device or register.
Array size is out of range for address '<address>'
Array support is not available for the specified address: '<address>'
Data Type '<type>' is not valid for device address '<address>'
Device address '<address>' contains a syntax error
Device address '<address>' is not supported by model '<model name>'
Device address '<address>' is Read Only
Missing address
Device Status Error Messages
Device '<device name>' is not responding
Unable to bind to adapter: '<adapter name>' for device '<device name>'. Connection failed
Unable to write to '<address>' on device '<device name>'
Scanivalve Ethernet
Overview
Setup
Channel Properties — General
Channel Properties — Ethernet Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Tag Generation
Device Properties — TCP/IP
Optimizing Scanivalve Ethernet Communications
Data Types Description
Address Descriptions
DSA 3200 Addressing
DTS 3250 Addressing
Error Descriptions
Missing address
Device address <address> contains a syntax error
Address <address> is out of range for the specified device or register
Device address <address> is not supported by model <model name>
Data Type <type> is not valid for device address <address>
Device address <address> is Read Only
Device <device name> is not responding
Failure to initiate 'winsock.dll'
Device <device name> received bad response on tag <address>
Siemens S5
Overview
Setup
Channel Properties — General
Channel Properties — Serial Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Channel Properties — Communication Serialization
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Data Types Description
Address Descriptions
Siemens S5 (AS511) 90U Address Descriptions
Siemens S5 (AS511) 95U Address Descriptions
Siemens S5 (AS511) 100U - 100 Address Descriptions
Siemens S5 (AS511) 100U - 101 Address Descriptions
Siemens S5 (AS511) 100U - 103 Address Descriptions
Siemens S5 (AS511) 101U Address Descriptions
Siemens S5 (AS511) 115U - 941 Address Descriptions
Siemens S5 (AS511) 115U - 942 Address Descriptions
Siemens S5 (AS511) 115U - 943 Address Descriptions
Siemens S5 (AS511) 115U - 944 Address Descriptions
Siemens S5 (AS511) 115U - 945 Address Descriptions
Siemens S5 (AS511) 135U - 921 Address Descriptions
Siemens S5 (AS511) 135U - 922 Address Descriptions
Siemens S5 (AS511) 135U - 928 Address Descriptions
Siemens S5 (AS511) 155U - 946 Address Descriptions
Siemens S5 (AS511) 155U - 947 Address Descriptions
Event Log Messages
Error Mask Definitions
Siemens S7 MPI
Overview
Setup
Channel Properties — General
Channel Properties — Serial Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Channel Properties — S7 MPI Settings
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Data Types Description
Address Descriptions
Event Log Messages
Error Mask Definitions
Siemens S7 Plus Ethernet
Overview
Setup
Channel Properties — General
Diagnostics Note
Channel Properties — Ethernet Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device ID Note
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Tag Generation
Tag Generation Notes
Device Properties — Communications
Siemens and Media-Level Redundancy Support
Optimizing Communications
Data Types Description
Data Type Mapping
Address Descriptions
Event Log Messages
Event Log Messages
Error Reason Explanations
Appendix — Reloading Tags
Help Contents
Overview
Setup
Channel Properties — General
Channel Properties — Ethernet Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device ID Note
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Tag Generation
Tag Generation Notes
Device Properties — Communications
Siemens and Media-Level Redundancy Support
Optimizing Communications
Data Types Description
Data Type Mapping
Address Descriptions
Event Log Messages
Event Log Messages
Error Reason Explanations
Appendix — Reloading Tags
Siemens S7-200
Overview
Setup
Channel Properties — General
Channel Properties — Serial Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Channel Properties — Communication Serialization
Channel Properties — Siemens Client ID
Device Properties — Identification
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Data Types Description
Address Descriptions
S7-200 Addressing
S7-200 PPM Addressing
Event Log Messages
Event Log Messages
Error Mask Definitions
Siemens S5 3964R
Overview
Setup
Data Types Description
Address Descriptions
Event Log Messages
Event Log Messages
Error Mask Definitions
Siemens TCP/IP Ethernet
Overview
Setup
Channel Properties — General
Channel Properties — Ethernet Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Operating Mode
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Tag Generation
Device Properties — Communications Parameters
Device Properties — S7 200
Device Properties — Addressing Options
Device Properties — Tag Import
Siemens TCP/IP Ethernet Device Setup with API Commands
Enumerations
Device Model Enumerations
Optimizing Communications
Data Types Description
Address Descriptions
S7-200 Address Descriptions
S7-300 Address Descriptions
S7-400 Address Descriptions
S7-1200 Address Descriptions
S7-1500 Address Descriptions
NetLink: S7-300 Address Descriptions
NetLink: S7-400 Address Descriptions
Internal Tags
Item Syntax
Standard S7-300/400/1200/1500 Item Syntax
Legacy S7-300/400 Item Syntax
Event Log Messages
Event Log Messages
Error Codes
Appendix — Channel Properties
Appendix — Device Properties
Appendix — Tag Properties
Configuring Siemens Connections
How To Configure S7-200 Connections in Micro/WIN
How To Configure S7-300/400 Connections in STEP 7
How To Configure S7-1200 Connections with the Totally Integrated Automation (TIA) Portal
How To Configure S7-1500 Connections
Appendix: Alternate Syntax Support
Applicom Direct-Link Item Syntax
INAT OPC Server TCPIPH1 Item Syntax
Siemens Simatic Net Item Syntax
Siemens STEP 7 Item Syntax
Softing S7/S5 OPC Server Item Syntax
Siemens TCP/IP Ethernet for Edge
Overview
Setup
Channel Properties — General
Channel Properties — Ethernet Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Operating Mode
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Tag Generation
Device Properties — Communications Parameters
Device Properties — S7 200
Device Properties — Addressing Options
Device Properties — Tag Import
Siemens TCP/IP Ethernet Device Setup with API Commands
Enumerations
Device Model Enumerations
Optimizing Communications
Data Types Description
Address Descriptions
S7-200 Address Descriptions
S7-300 Address Descriptions
S7-400 Address Descriptions
S7-1200 Address Descriptions
S7-1500 Address Descriptions
NetLink: S7-300 Address Descriptions
NetLink: S7-400 Address Descriptions
Internal Tags
Item Syntax
Standard S7-300/400/1200/1500 Item Syntax
Legacy S7-300/400 Item Syntax
Event Log Messages
Event Log Messages
Error Codes
Appendix — Channel Properties
Appendix — Device Properties
Appendix — Tag Properties
Siemens TCP/IP Server Ethernet
Overview
Setup
Channel Properties — General
Channel Properties — Ethernet Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Channel Properties — Communications Properties
Device Properties — General
Device Properties — Scan Mode
Device Properties — CPU Settings
Siemens Client Device Configuration
Internal Tags
Data Types Description
Address Descriptions
Event Log Messages
Event Log Messages
Configuring Connections Using the SIMATIC Manager
Step 1: Creating a New Project
Step 2: Configuring the Siemens Client and PC Station
Step 3: Connecting the Siemens Client and the Siemens Server Driver
Step 4: Inserting Function Blocks
Step 5: Creating the DB3 Data Block
Step 6: Inserting PUT FB
Step 7: Downloading to the PLC
Simatic / TI 505 Ethernet
Overview
Setup
Channel Properties — General
Channel Properties — Ethernet Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — 505 Protocol
Device Properties — Addressing Options
Device Properties — Communications Parameters
Optimizing Communications
Data Types Description
Address Descriptions
Addressing
Common Data Type Addressing
Status Words
Alarm Addressing
AVF Bit Definitions
ACF Bit Definitions
Loop Addressing
LVF Bit Definitions
LCF Bit Definitions
LRSF Bit Definitions
Find Forced Addressing
Error Descriptions
Address <address> is out of range for the specified device or register.
Array size is out of range for address <address>.
Array support is not available for the specified address: <address>.
Data type <type> is not valid for device address <address>.
Device address <address> contains a syntax error.
Device address <address> is read only.
Device <device name> cannot execute a read request (<address>, <size>).
Device <device name> cannot execute a write request (<address>, <size>).
Device <device name> detected a NITP Protocol error (tag <address>, size <size>).
Device <device name> detected a Task Code error <error> (tag <address>, size <size>).
Device <device name> input queue is full. The module is receiving requests faster than it can process requests.
Device <device name> is not responding.
Device <device name> responded with Extended error <error> (tag <address>, size <size>).
Device <device name>, write value not in range 1-->65536. (Tag 'FFSTART').
Missing address.
Unable to write to <address> on device <device name>.
Winsock initialization failed (OS Error = n).
Winsock V1.1 or higher must be installed to use the Simatic/TI 505 Ethernet device driver.
Task Error Codes
Simatic / TI 505 Serial
Overview
Setup
Data Types Description
Address Descriptions
NITP Addressing
Transparent Byte Addressing
Status Words
Error Descriptions
Address Validation
Missing address
Device address '<address>' contains a syntax error
Address '<address>' is out of range for the specified device or register
Data Type '<type>' is not valid for device address '<address>'
Device address '<address>' is Read Only
Array size is out of range for address '<address>'
Array support is not available for the specified address: '<address>'
Serial Communications
COMn does not exist
Error opening COMn.
COMn is in use by another application
Unable to set comm properties on COMn
Error Codes
Communications error on '<channel name>' [<error mask>]
Device Status Messages
Device '<device name>' is not responding
Unable to write to '<address>' on device '<device name>'
Simatic/TI 505 Serial Device Specific Messages
Unable to write tag <address> for device <device name>: Error code <code>
Unable to read block starting at <address> for device <device name>: Error code <code>
Bad address in block [<start address> to <end address>] on device '<device name>'
Simulator
Overview
Setup
Channel Properties — General
Channel Properties — Write Optimizations
Channel Properties — Advanced
Channel Properties — Persistence
Configuration API Service — Channel Properties
Device Properties — General
Device Properties — Scan Mode
Device Properties — Tag Generation
Configuration API Service — Device Properties
Data Types Description
Address Descriptions
8-Bit Device Addresses
16-Bit Device Addresses
Simulation Functions
Ramp Function
Random Function
Sine Function
User Function
Event Log Messages
Event Log Messages
SIXNET EtherTRAK
Overview
Setup
Channel Properties — General
Channel Properties — Ethernet Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — TCP/IP
Device Properties — Blocks
Addressing RemoteTRAK Devices Over the Ethernet
Optimizing Your SIXNET EtherTRAK Communications
Data Types Description
Address Descriptions
Error Descriptions
Address Validation
Missing address
Device address '<address>' contains a syntax error
Address '<address>' is out of range for the specified device or register
Data Type '<type>' is not valid for device address '<address>'
Device address '<address>' is read only
Array size is out of range for address '<address>'
Array support is not available for the specified address: '<address>'
Device Status Messages
Device '<device name>' is not responding
Unable to write to '<address>' on device '<device name>'
Driver Error Messages
Winsock initialization failed (OS Error = n)
Winsock V1.1 or higher must be installed to use the SIXNET EtherTRAK device driver
Device Specific Messages
Bad address in block [<start address> to <end address>] on device '<device name>'
Block size mismatch reading [<start address> to <end address>] on device '<device name>
Block request [<start address> to <end address>] on device '<device name>.' responded with exception = n
SIXNET UDR
Overview
External Dependencies
Setup
SIXNET Software Components: Universal Driver Components
Networks
Channel Properties — General
Channel Properties — Write Optimizations
Channel Properties — Advanced
Channel Properties — Communications
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Tag Generation
Device Properties — Station
Device Properties — Settings
Device Properties — Block Sizes
Device Properties — Tag Import
UDR Server Devices
Data Types Description
Address Descriptions
Client Open Model Addressing
Server Model Addressing
Optimizing Ethernet Communications
Automatic Tag Database Generation
Error Descriptions
Address Validation
Missing address
Device address '<address>' contains a syntax error
Address '<address>' is out of range for the specified device or register.
Data Type '<type>' is not valid for device address '<address>'
Device address '<address>' is Read Only
Array size is out of range for address '<address>'
Array support is not available for the specified address: '<address>'
Device Status Messages
Device '<device name>' is not responding
Unable to write to '<address>' on device '<device name>'
Driver Error Messages
Could not allocate memory for UDR server device '<device name>'
Failed to create SIXNET interface for UDR client devices on channel '<channel>'
Failed to create SIXNET interface for UDR server device '<station number>' on channel
Failed to open session for devices on channel '<channel>'
Failed to open session for UDR server device '<station number>' on channel '<channel>'
Failed to build request for device '<station number>' on channel '<channel>'
Failed to send request for device '<station number>' on channel '<channel>'
Failed to build ACK for device '<station number>' on channel '<channel>'
Failed to send ACK for device '<station number>' on channel '<channel>'
Failed to build NAK for device '<station number>' on channel '<channel>'
Failed to send NAK for device '<station number>' on channel '<channel>'
Automatic Tag Database Generation Messages
Tag import failed due to low memory resources
File exception encountered during tag import
Imported tag name changed from '<old name>' to '<new name>' (record: <record>)
Tag '<name>' (record: <record>) could not be imported due to name conflict
Tag not imported due to unknown I/O type (record: <record>)
Tag could not be imported due to unsupported datatype (record: <record>)
SNMP
Overview
Setup
Channel Properties — General
Channel Properties — Ethernet Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Channel Properties — Communication Serialization
Device Discovery Procedure
Discovery Settings
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Tag Generation
Device Properties — Communications
Device Properties — v3 Security
Device Properties — MIB Import
Device Properties — Trap / Inform Notifications
Device Properties — Network Analyst
Data Types Description
Historical Data Attributes
Previous Value
Delta Time
Moving Average
Address Descriptions
About SNMP Addresses
About MIB Modules
About Network Analyst Tags
Trap Tags
SNMP Trap Messages
Trap Events Queue
Auto Created Trap Tags
Message Descriptions
Address Validation
Address <address> is out of range for the specified device or register.
Data Type <type> is not valid for device address<address>.
Device address <address> contains a syntax error.
Device address <address> is read only.
The remote device reports that the requested name <OID> does not exist on <device name>.
Runtime Messages
<Channel name>.<device name>: unable to open a SNMP session to host <host> on port <port>, using protocol <protocol>.
<Channel name>.<device name>: Unable to establish a trap listener on port <port>, using protocol <protocol>.No trap events will be received.
Access to address <address> on <channel name>.<device name> is not permitted.
Address <address> on <channel name>.<devicename> is not writable.
Address <address> on <channel name>.<device name> is unavailable.
Device <device name> does not support the necessary information required to perform network analysis. Network Analyst tags will be disabled for this device.
Device <device name> does not support the number of ports currently configured in this application. Network Analyst tags will be disabled for this device.
Device <device name> is not responding.
Device Discovery has exceeded <max devices> maximum allowed devices.
High-capacity counters for network analysis are not available for device <device name>. Attempting to use low capacity counters.
The remote device reports that the requested name <name>does not exist on <channel name>.<device name>.
The response message for the current transaction on <channel name>.<device name> would have been too large, and hasbeen discarded by the remote device.
Unable to bind trap socket on binding address <address>, port <port>, and protocol <protocol> for device <device>.
Unable to bind trap socket on binding address <IP address>, port <port number> and protocol <protocol> for device <device name>.
Unable to create communications thread on trap socket for binding address <IP address>, port <port number>, and protocol <protocol> for device <device name>.
Unable to create listener on trap socket for binding address <IP address>, port <port number> and protocol <protocol> for device <device name>.
Unable to create trap socket on binding address <IP address>, port <port number> and protocol <protocol> for device <device name>.
Unable to load authentication and privacy passphrases for device <device name>. Please specify an authentication and privacy passphrase in the SNMP v3 Security property group of Device Properties.
Unable to load authentication passphrase for device <device name>. Please specify an authentication passphrase in the SNMP v3 Security property group of Device Properties.
Unable to load username for device <device name>. Please specify a username in the SNMP v3 Security property group of Device Properties.
Unable to resolve host address <IP address> on device <device name> for trap processing.
Unable to send transaction: <reason>.
SNMP Agent Error Messages
Data for address <address> on <channel name>.<device name> has an inconsistent value.
Data for address <address>on <channel name>.<device name> has the wrong encoding.
Data for address <address> on <channel name>.<device name> has the wrong length.
Data for address <address>on <channel name>.<device name> has the wrong value.
XML Messages
Invalid XML document [Reason: The excluded port list is invalid for device <device name>].
Invalid XML document [Reason: Port Status 0 limit must be less than port Status 1 limit for device <device name>].
Communications Messages
Unable to bind to adapter: <adapter address>. Connect failed. Winsock Err # n.
Winsock initialization failed (OS Error = n).
Winsock shut down failed (OS Error = n).
Winsock V1.1 or higher must be installed to use the SNMP device driver.
Authentication Messages
The authentication passphrase fields do not match. Please retype the passphrase identically in both fields.
The privacy passphrase fields do not match. Please retype the passphrase identically in both fields.
MIB Parser Messages
Cannot redefine macro name.
Cannot redefine primitive type.
Close IMPORTS statement with a ';'.
Could not add object: <object name>; parent object: <parent object name> undefined.
Could not find module: <module name> to import.
Could not obtain MIB module information.
DEFINITIONS must directly follow MIB module name.
End one module definition before beginning another.
Failed to open file: <file path>.
Invalid assignment valu.e
Invalid DESCRIPTION value.
Invalid ENTERPRISE value.
Invalid MAX-ACCESS value.
Invalid module name.
Invalid NOTIFICATION-TYPE clause.
Invalid object assignment.
Invalid OBJECT-IDENTITY clause.
Invalid OBJECT-TYPE clause.
Invalid OBJECTS value.
Invalid octet or bit string.
Invalid parent object name.
Invalid STATUS value.
Invalid SYNTAX value.
Invalid TRAP-TYPE assignment.
Invalid TRAP-TYPE clause.
Open bracket not closed.
Open parenthesis not closed.
Sub-identifier out of range: 0 to 4294967295.
Syntax Error.
Undefined identifier: <identifier name>.
Security Related Messages
<channel name>.<device name> reports a decryption error. Check the privacy passphrase.
<channel name>.<device name> reports the authentication digest is incorrect. Check the authentication passphrase.
<Channel name>.<device name> reports the request was not within the time window.
<channel name>.<device name> reports the specified security level is not supported
<channel name>.<device name> reports the specified user is unknown.
<channel name>.<device name> responded to a request with a Report-PDU containing no valid data.
Square D
Overview
Setup
Channel Properties — General
Channel Properties — Serial Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Settings
Route ID
Data Types Description
Address Descriptions
SYMAX Addressing
Square D Serial Power Logic Addressing
Error Descriptions
Address Validation
Missing address
Device address '<address>' contains a syntax error
Address '<address>' is out of range for the specified device or register
Device address '<address>' is not supported by model '<model name>'
Data Type '<type>' is not valid for device address '<address>'
Device address '<address>' is Read Only
Array size is out of range for address '<address>'
Array support is not available for the specified address: '<address>'
Serial Communications
COMn does not exist
Error opening COMn
COMn is in use by another application
Unable to set comm parameters on COMn
Communications error on '<channel name>' [<error mask>]
Device Status Messages
Device '<device name>' is not responding
Unable to write to '<address>' on device '<device name>'
Device Specific Messages
Bad address in block [<start address> to <end address>] on device '<device name>'
The Square D Serial device appears to be sending unsolicited messages
System Monitor
Overview
Setup
Channel Properties — General
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Device Properties — Import
Tag Descriptions
Device Properties — Settings
Data Types Description
Address Descriptions
Error Descriptions
Counter <counter> contains invalid data
Counter <counter> has a negative denominator
Counter <counter> has a negative time base
Counter <counter> has a negative value
Counter <counter> is not valid
Counter <counter> was not found
Devices of model type N/A cannot be multidropped
Failed to retrieve instances for object
Instance <instance> was not found
Performance <object> was not found
T-W Drivers
Thermo Westronics Ethernet
Overview
Setup
Channel Properties — General
Channel Properties — Ethernet Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Tag Generation
Device Properties — TCP/IP
Device Properties — Block Sizes
Device Properties — Settings
Optimizing Communications
Data Types Description
Address Descriptions
SV100 Addressing
SV180 Addressing
SV180 (2.0) Addressing
Error Descriptions
Address Validation
Missing address
Device address <address> contains a syntax error
Address <address> is out of range for the specified device or register
Device address <address> is not supported by model <model name>
Data Type <type> is not valid for device address <address>
Device address <address> is Read Only
Array size is out of range for address <address>
Array support is not available for the specified address: <address>
Device Status Messages
Device <device name> is not responding
Unable to write to <address> on device <device name>
Thermo Westronics Ethernet Device Specific Messages
Failure to initiate 'winsock.dll'
Bad address in block [<start address> to <end address>] on device <device name>
Thermo Westronics Serial
Overview
Setup
Channel Properties — General
Channel Properties — Serial Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Tag Generation
Device Properties — Block Sizes
Device Properties — Settings
Data Types Description
Address Descriptions
Series 1200 Addressing
Series 1600 Addressing
Series 3000 Addressing
SM100 Addressing
SV100 Addressing
SV180 Addressing
SV180 (2.0) Addressing
Error Descriptions
Address Validation
Address <address> is out of range for the specified device or register
Array size is out of range for address <address>
Array support is not available for the specified address: <address>
Data type <type> is not valid for device address <address>
Device address <address> contains a syntax error
Device address <address> is not supported by model <model name>
Device address <address> is read only
Missing address
Serial Communications
Communications error on <channel name> [<error mask>]
COMn does not exist
COMn is in use by another application
Error opening COMn
Unable to set comm properties on COMn
Device Status Messages
Device <device name> is not responding
Unable to write to <address> on device <device name>
Thermo Westronics Serial Device Specific Messages
Bad address in block [<start address> to <end address>] on device <device name>
Bad array spanning [<address> to <address>] on device <device name>
Failed to read SM100 decimal placement data
TIWAY Host Adapter
Overview
Setup
Channel Properties — General
Channel Properties — Serial Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Channel Properties — Adapter
Channel Properties — Network Manager
Channel Properties — Channel A/B
Channel Properties — HIU (Host Interface Unit)
Channel Properties — Macro Setup
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Addressing Options
Data Types Description
Address Descriptions
Standard Data Type Addressing
Standard Data Type Addressing
SS Bit Definitions
Alarm Addressing
Alarm Addressing
AVF Bit Definitions
ACF Bit Definitions
Loop Addressing
Loop Addressing
Loop V-Flag Bit Definitions
LCF Bit Definitions
LRSF Bit Definitions
UHA Status & Control Addressing
UHA Status & Control Addressing
Macro Addressing
Macro Addressing
UNILINK Macros
Channel Properties — Macro Setup
Defining Read Macros
Defining Link Macros
Macro Enable/Disable Status
Macro Response Status Word (MRSW)
Error Descriptions
Address Validation
Address <address> is out of range for the specified device or register
Array size is out of range for address <address>
Array support is not available for the specified address: <address>
Data Type <type> is not valid for device address <address>
Device address <address> contains a syntax error
Device address <address> is read only
Missing address
Serial Communications
Communications error on <channel name> [<error mask>]
COMn does not exist
COMn is in use by another application
Error opening COMn
Unable to set comm properties on COMn
Device Status Messages
Device <device name> is not responding
Device Specific Messages
Adapter reporting command timeout - Error 0x001. Reconfiguring adapter
Adapter reporting HIU not initialized - Error 0x100B. Reconfiguring adapter
Adapter reporting unrecognized command - Error 0x0084. Reconfiguring adapter
Host adapter not responding
Secondary device <device name> no longer connected to network. Reconnecting secondary
Read Errors
Unable to read block starting at <address> on device <device name>: Adapter Error <code>
Unable to read block starting at <address> on device <device name>: Adapter Error <code>. Block deactivated
Unable to read block starting at <address> on device <device name>: Framing Error
Unable to read block starting at <address> on device <device name>: Secondary Error: <code>
Unable to read block starting at <address> on device <device name>: Secondary Error: <code>. Block deactivated
Unable to read tag <address> on device <device name>: Task Error: <code>
Unable to read tag <address> on device <device name>: Task Error: <code>. Tag deactivated
Write Errors
Unable to write to <address> on device <device name>.'
Unable to write tag <address> on device <device name>: Adapter Error <code>
Unable to write tag <address> on device <device name>: Framing Error
Unable to write tag <address> on device <device name>: Secondary Error: <code>
Unable to write tag <address> on device <device name>: Task Error: <code>
Macro Specific Messages
Adapter reporting macro link error - Error 0x2020. Trigger macro cannot be configured for auto-enable
Macro tag address <address> is invalid given new macro definition. Tag deactivated
The macro referenced in tag address <address> is no longer available. Tag deactivated
Unable to read macro with source ID <ID>, macro #<num> on <device name>: Adapter Error <code>
Unable to read macro with source id <ID>, macro #<num> on <device name>: Adapter Error <code>. Block deactivated
Unable to read macro with source id <ID>, macro #<num> on <device name>: Framing Error
Unable to read macro with source id <ID>, macro #<num> on <device name>: MRSW Error <code>
Unable to read macro with source id <ID>, macro #<num> on <device name>: MRSW Error <code>. Block deactivated
Unable to read macro with source id <ID>, macro #<num> on <device name>: Secondary Error <code>
Unable to read macro with source id <ID>, macro #<num> on <device name>: Secondary Error <code>. Block deactivated
Unable to read macro with source id <ID>, macro #<num> on <device name>: Task Error <code>
Unable to read macro with source id <ID>, macro #<num> on <device name>: Task Error <code>. Tag deactivated
XML Error Messages
XML Loading Error: An existing link macro already has this macro number: <num>. Link macro not loaded
XML Loading Error: An existing read macro already has this macro number: <num>. Link macro not loaded
XML Loading Error: An existing read macro already has this macro number: <num>. Read macro not loaded
XML Loading Error: Invalid value found. Link macro not loaded
XML Loading Error: Invalid value found. Read macro not loaded
XML Loading Error: Link macro linked to missing read macro <num>. Link macro not loaded
XML Loading Error: Read macro(s) missing from file. Link macro(s) not loaded
Error Codes
Adapter Error Codes
Secondary Error Codes
Task Error Codes
MRSW Termination Codes
Torque Tool Ethernet
Overview
Setup
Channel Properties — General
Channel Properties — Ethernet Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Communications Parameters
Device Properties — Settings
Optimizing Communications
Data Types Description
Address Descriptions
Message IDs
Command Sets
Command Set: Alarm
Command Set: Auto-Disable Settings
Command Set: Communication
Command Set: Dynamic Job Request
Command Set: Flash
Command Set: Identifiers
Command Set: IO Interface
Command Set: Job Info
Command Set: Job Data
Command Set: Job Number Data
Command Set: Last Tightening Results
Command Set: Multi Spindle Results
Command Set: Old Tightening Results
Command Set: Operation Result
Command Set: Parameter Set Data
Command Set: Parameter Set Numbers
Command Set: Parameter Set Selected
Command Set: Program Messages
Command Set: Selector Messages
Command Set: Time
Command Set: Tool Data
Command Set: Trace Curve Data Messages
Command Set: User Data Messages
Command Set: VIN
Event Log Messages
Error Descriptions
Address Validation Errors
Address <address> is out of range for the specified device or register.
Array size is out of range for address <address>.
Array support is not available for the specified address: <address>.
Data type <type> is not valid for device address <address>.
Device address <address> contains a syntax error.
Device address <address> is read only.
Subscription failed for device
Ethernet Errors
Unable to bind to adapter: <adapter name>. Connect failed.
Winsock initialization failed (OS error = <error>).
Winsock shut down failed (OS Error = <error>).
Winsock V1.1 or higher must be installed to use the driver.
Runtime Errors
Device <device name> failed to connect.
Device <device name> is not responding.
Unable to read tag <tag name>: Device <device name> encountered a parsing error.
Unable to read tag <tag name>: Device <device name> received an error response (Error <error code>).
Unable to read unsolicited packed data group: Device '<device>' received an error response (Error <error num>).
Unable to write tag <tag name>: Device <device name> encountered a parsing error.
Unable to write tag <tag name>: Device <device name> received an error response (Error <error code>).
Unable to write tag <tag name>: Device <device name> received invalid data for write.
Unable to write to <address> on device <device name>.
Error Codes
Error Codes
Appendix — Dynamic Job Request
Appendix — Tightening Program Read/Write
Appendix — LTR Revision 998 Tag Behavior
Toshiba Serial
Setup
Channel Properties — General
Channel Properties — Serial Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Data Types Description
Address Descriptions
EX100 Addressing
EX200 Addressing
EX500 Addressing
T1, T1 Super Addressing
T2 Addressing
T3, T3H Addressing
Error Descriptions
Address Validation
Missing address
Device address '<address>' contains a syntax error
Address '<address>' is out of range for the specified device or register
Data Type '<type>' is not valid for device address '<address>'
Device address '<address>' is not supported by model '<model name>'
Device address '<address>' is Read Only
Serial Communications
COMn does not exist
Error opening COMn
COMn is in use by another application
Unable to set comm properties on COMn
Communications error on '<channel name>' [<error mask>]
Device Status Messages
Device '<device name>' not responding
Unable to write to address '<address>' on device '<device name>'
Toshiba Ethernet
Overview
Setup
Channel Properties — General
Channel Properties — Ethernet Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Communications Parameters
Optimizing Communications
Data Types Description
Address Descriptions
T2 Addressing
T3H Addressing
S2 Addressing
S3 Addressing
Error Descriptions
Address Validation
Address <address> is out of range for the specified device or register
Data Type <type> is not valid for device address <address>
Device address <address> contains a syntax error
Device address <address> is not supported by model <model name>.'
Device address <address> is read only
Missing address
Device Status Messages
Deactivating tag block. Bad address in block [<start address> to <end address>] on device <device name>
Device <device name> not responding
Device <device name> responded with error code 'n' (Tag <tag name>)
Unable to write to address <address> on device <device name>
Winsock initialization failed (OS Error = n)
Winsock V1.1 or higher must be installed to use the Toshiba Ethernet device driver
Hardware Configuration
S Series Setup
T2 and T3 Setup
Toyopuc PC3/PC2 Ethernet
Overview
Setup
Channel Properties — General
Channel Properties — Ethernet Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Communications Parameters
Data
Diagnostics Tags
Multi-Point Read Support
Data Types Description
Address Descriptions
PC2/PC2 Interchange Mode Address Descriptions
PC3 Address Descriptions
PC10G / Nano 10GX Address Descriptions
Event Log Messages
Address <address> is out of range for the specified device or register
Array size is out of range for address <address>.
Array support is not available for the specified address:<address>.
Device address <address> contains a syntax error.
Data Type <type> is not valid for device address <address>.
Device address <address> is read only.
Device <device name> is not responding.
Missing Address.
Read request failed. Device responded with an error. Tag Address = <address>.
Read request failed due to a framing error. Tag Address = <address>.
Unable to write to <address> on device <device name>.
Write request failed due to a framing error. Tag Address = <address>.
Write request failed. Device responded with an error. Tag Address = <address>.
Error Response Data: Error Code Table
Appendix: Configuring Modules
Configuring the PC10G-CPU for Ethernet Communications
Configuring the FL/ET-T-V2 Ethernet Module
Configuration Ladder for EN-I/F Ethernet Module
Toyopuc Serial
Overview
Setup
Channel Properties — General
Channel Properties — Serial Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Diagnostics Tags
Multi-Point Read Support
Data Types Description
Address Descriptions
Error Descriptions
Address Validation
Missing address
Device address '<address>' contains a syntax error
Address '<address>' is out of range for the specified device or register
Device address '<address>' is not supported by model '<model name>'
Data Type '<type>' is not valid for device address '<address>'
Device address '<address>' is Read Only
Array size is out of range for address '<address>'
Array support is not available for the specified address: '<address>'
Serial Communications
COMn does not exist
Error opening COMn
COMn is in use by another application
Unable to set comm properties on COMn
Communications error on '<channel name>' [<error mask>]
Device Status Messages
Device '<device name>' is not responding
Unable to write to '<address>' on device '<device name>'
Device-Specific Messages
Bad address in block [<start address> to <end address>] on device '<device name>'
Triconex Ethernet
Overview
Setup
Channel Properties — General
Channel Properties — Write Optimizations
Channel Properties — Advanced
Channel Properties — Network Interface
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Tag Generation
Device Properties — CM Configuration
Device Properties — Communications
Device Properties — Tag Import
Network Redundancy
Optimizing Communications
Automatic Tag Database Generation
Data Types Description
Address Descriptions
Tricon Addressing
Triconex Addressing
Trident Addressing
Device System Tags
Error Descriptions
Address Validation
Address '<address>' is out of range for the specified device or register
Data Type '<type>' is not valid for device address '<address>'
Device address '<address>' contains a syntax error
Device address '<address>' is not supported by model '<model name>'
Device address '<address>' is Read Only
Missing address
Device Status Messages
Could not detect available network adapters for <primary/secondary> network
Device '<device name>' is not responding
Failed to load Winsock or related library
Tag import error - invalid bin in item path: '<item path>'
Tag import error - invalid item path format: '<item path>'
Tag import error - invalid name: '<tag name>'
Tag import error - invalid offset in item path: '<item path>'
Tag import failed. Could not find data for node '<node>'
Tag import failed. Could not open file '<file>'
Tag import failed due to unexpected XML format in '<file>'
Tag import failed. No import file name or system tags specified
Unable to process data update on device '<device>'. CRC error
Unable to process data update on device '<device>'. Unexpected message format
Unable to process data update on device '<device>'. Unexpected model
Unable to process data update on device '<device>'. Unexpected node number
Unable to use network redundancy on channel '<channel>'
Unable to use specified primary network adapter '<adapter>' on channel '<channel>'
Unable to use specified secondary network adapter '<adapter>' on channel '<channel>'
Winsock initialization failed (OS Error = <error code>)
Winsock V1.1 or higher must be installed to use the Triconex Ethernet device driver
Write failed for tag '<address>' on device '<device>'. CRC error
Write failed for tag '<address>' on device '<device>'. No data for Read/Modify/Write
Write failed for tag '<address>' on device '<device>'. Timeout
Write failed for tag '<address>' on device '<device>'. TSAA Response Code: <code>
Write failed for tag '<address>' on device '<device>'. Unexpected model
Write failed for tag '<address>' on device '<device>'. Unexpected node number
Write failed for tag '<address>' on device '<device>'. Unexpected response format
Telemecanique Uni-Telway
Overview
Setup
Channel Properties — General
Channel Properties — Serial Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Channel Properties — Driver Setup
Device Properties — General
Device Properties — Scan Mode
Device Properties — Auto-Demotion
Device Properties — Address
Device Properties — Timeout
Data Types Description
Address Descriptions
Small Frame Addresses
Large Frame Addresses
Error Descriptions
Address Validation
Missing address
Device address <address> contains a syntax error
Address <address> is out of range for the specified device or register
Data type <type> is not valid for device address <address>
Device address <address> is read only
Serial Communications
COMn does not exist
Error opening COMn
COMn is in use by another application
Unable to set comm properties on COMn
Communications error on <channel name> [<error mask>]
Device Status Messages
Device <device name> is not responding
Unable to write to <address> on device <device name>
Device <device name> responded with error <error byte> (Tag <address>, Size <size>)
Device <device name> Negative response returned (Tag <address>, Size <size>)
Device <device name> response invalid (Tag <address>, Size <size>)
Universal Device
Overview
Architecture
Setup
Channel Properties
Channel Properties — General
Channel Properties — Ethernet Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Channel Properties — Profile
Setup
Device Properties — General
Device Properties — Scan Mode
Device Properties — Communication Transport
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — File Mode
Device Properties — User-Defined Settings
Data Types Descriptions
Event Log Messages
Event Log Messages
Sample Profiles
WAGO Ethernet
Overview
Setup
Channel Properties — General
Channel Properties — Ethernet Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Tag Generation
Device Properties — Communications Parameters
Device Properties — Block Sizes
Device Properties — Slot Configuration
Analog Input Modules
Analog Output Modules
Binary Spacer Module
Digital Input Modules
Digital Output Modules
Encoder and Resolver Modules
Generic Module
Power Supply and End Modules
Special Modules
Optimizing Communications
Data Types Description
Address Descriptions
750-342 Buscoupler
750-842 Programmable Fieldbus Controler (PFC)
Process Image
Input Coils
Output Coils
Internal Registers
Holding Registers
Tag Naming Convention
Error Descriptions
Address Validation
Missing address
Device address <address> contains a syntax error
Address <address> is out of range for the specified device or register
Device address <address> is not supported by model <model name>
Data Type <type> is not valid for device address <address>
Device address <address> is Read Only
Array size is out of range for address <address>
Array support is not available for the specified address: <address>
Device Status Messages
Device <device name> is not responding
Unable to write to <address> on device <device name>
Device Specific Messages
Failure to initiate 'winsock.dll'
Bad address in block [x to y] on device <device name>
Bad received length [x to y] on device <device name>
Weatherford 8500
Overview
Setup
Channel Properties — General
Channel Properties — Serial Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Channel Properties — Communication Serialization
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Tag Generation
Device Properties — Communications
Data Types Description
Address Descriptions
Function Items
Buffer Items
Command Items
Well Command Items
Dynagraph and Xdynagraph10 Items
Surface and Downhole Items
Parameter Items
Statistics Items
WellPilot RPOC Parameter Listings
Parameters 1-300
Parameters 301-600
Parameters 601-900
Parameters 901-1199
Parameters 1202-1500
Parameters 1501-1800
Parameters 1801-2100
Parameters 2100-2400
Parameters 2401-2700
Parameters 2701-3000
Parameters 3001-3300
Parameters 3301-3659
WellPilot/ePIC VSD Parameter Listings
Parameters 1-300
Parameters 309-599
Parameters 601-900
Parameters 901-1199
Parameters 1201-1500
Parameters 1501-2524
ePIC RPC Parameter Listings
Parameters 1-300
Parameters 309-599
Parameters 601-900
Parameters 901-1180
M2000 Parameter Listings
Parameters 1-300
Parameters 309-600
Parameters 601-862
8800 Parameter Listings
Parameters 1-300
Parameters 301-600
Parameters 601-862
8750/8650/8500 Parameter Listings
Parameters 1-300
Parameters 309-600
Parameters 601-669
Recommended Function, Buffer, and Command Items Usage
Error Descriptions
Address <address> is out of range for the specified device or register.
Address in block [Parameters: <parameter number list>] on device <device name> responded with exception code <code>.
Array size is out of range for address <address>.
Block address [<start address> to <end address>] on device <device name> responded with exception code <code>.
Data type ‘<type>’ is not valid for device address <address>.
Device address <address> contains a syntax error.
Device <device name> is not responding.
Query of parameter 619 setting on device <address> returned unexpected value <value>. Using actual position values.
Unable to generate a tag database for device <device name>. Reason: Memory allocation error.
Unable to load <dll>.
Unable to read from address <address> on device <device name>: Device responded with exception code <code>.
Unable to write to address <address> on device <device name>: Device responded with exception code <code>.
Error Codes
Exception Codes
Frame Process Error Codes
WITS Level 0 Active
Overview
Setup
Channel Properties — General
Channel Properties — Serial Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Channel Properties — Request
Channel Properties — Timeout
Device Properties — General
Device Properties — Scan Mode
Device Properties — Tag Generation
Device Properties — Settings
Data Types Description
Address Descriptions
Error Descriptions
Device '<device name>' item '<WITS ID>', Write value length exceeds maximum frame length. Truncating to 1024 bytes
Device '<device name>', Abandoning current message after <time in ms> ms of inactivity
Device '<device name>', Invalid delimiter. Expecting '<configured delimiter>'. Discarding remainder of message
Device '<device name>', Message parsing error. Discarding remainder of message
Device '<device name>', More than 4096 bytes in item '<WITS ID>' data. Discarding remainder of message
Device '<device name>', Non-numeric WITS ID found: '<WITS ID>'. Discarding remainder of message
Device '<device name>', Non-printable character '<hex byte>' found in WITS ID. Discarding remainder of message
Device '<device name>', Non-printable character '<hex byte>' in item '<WITS ID>' data. Discarding remainder of message
Device '<device name>', Received Null value '<Null value>' for item '<WITS ID>'. Setting tag to bad quality
Device '<device name>', Request has timed out after <time in seconds> seconds of inactivity
Device '<device name>', Value '<value>' is invalid for item '<WITS ID>' with data type '<data type>'. Setting tag to bad quality
Device '<device name>', Value '<value>' out of range for item '<WITS ID>' with data type '<data type>'. Setting tag to bad quality
WITS Level 0 Passive
Overview
Setup
Channel Properties — General
Channel Properties — Serial Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Channel Properties — Timeout
Device Properties — General
Device Properties — Scan Mode
Device Properties — Tag Generation
Device Properties — Settings
Data Types Description
Address Descriptions
Error Descriptions
Device '<device name>' item '<WITS ID>', Write value length exceeds maximum frame length. Truncating to 1024 bytes
Device '<device name>', Abandoning current message after <time in ms> ms of inactivity
Device '<device name>', Communications have timed out after <time in seconds> seconds of inactivity
Device '<device name>', Invalid delimiter. Expecting '<configured delimiter>'. Discarding remainder of message
Device '<device name>', Message parsing error. Discarding remainder of message
Device '<device name>', More than 4096 bytes in item '<WITS ID>' data. Discarding remainder of message
Device '<device name>', Non-numeric WITS ID found: '<WITS ID>'. Discarding remainder of message
Device '<device name>', Non-printable character '<hex byte>' found in WITS ID. Discarding remainder of message
Device '<device name>', Non-printable character '<hex byte>' in item '<WITS ID>' data. Discarding remainder of message
Device '<device name>', Received Null value '<Null value>' for item '<WITS ID>'. Setting tag to bad quality
Device '<device name>', Value '<value>' is invalid for item '<WITS ID>' with data type '<data type>'. Setting tag to bad quality
Device '<device name>', Value '<value>' out of range for item '<WITS ID>' with data type '<data type>'. Setting tag to bad quality
Unable to write to address '<address>' on device '<device name>'. Invalid socket
Y Drivers
Yaskawa Memobus Plus
Overview
External Dependencies
Setup
Channel Properties — General
Channel Properties — Write Optimizations
Channel Properties — Advanced
Channel Properties — Adapter
Device Properties — General
Device ID
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Settings
Device Properties — Block Sizes
Optimizing Your Yaskawa Memobus Plus (SA85) Communications
Data Types Description
Yaskawa Memobus Plus (SA85) Address Descriptions
Output Coils
Input Coils
Internal Registers
Holding Registers
Global Data
Constant Registers
Link Coils
Link Registers
MC Coils
MC Control Coils
MC Relays
MC Control Relays
MC Code Relays
Error Descriptions
Address Validation
Missing address
Device address '<address>' contains a syntax error
Address '<address>' is out of range for the specified device or register
Data Type '<type>' is not valid for device address '<address>'
Device address '<address>' is Read Only
Array size is out of range for address '<address>'
Array support is not available for the specified address: '<address>'
Device Status Messages
Started MBPLUS.SYS device
Device '<device name>' is not responding
Unable to write to '<address>' on device '<device name>'
Device Specific Messages
Unable to start MBPLUS.SYS device
Unable to communicate with MBPLUS.VXD
Unable to open MBPLUS server path
Error opening MBPLUS path [<ID>]
Bad address in block [<start address> to <end address>] on device '<device name>'
Yaskawa MP Series Ethernet
Overview
Setup
Channel Properties — General
Channel Properties — Ethernet Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Communications Parameters
Device Properties — Block Sizes
Memory Mapping for MPxxxxiec Devices
Optimizing Communications
Data Types Description
Address Descriptions for MPxxxx (218IF Module) Devices
Address Descriptions for MPxxxxiec Devices
Error Descriptions
Address Validation
Address '<address>' is out of range for the specified device or register
Array size is out of range for address '<address>'
Array support is not available for the specified address: '<address>'
Data Type '<type>' is not valid for device address '<address>'
Device address '<address>' contains a syntax error
Device address '<address>' is not supported by model '<model name>'
Device address '<address>' is Read Only
Missing address
Device Status Messages
Device '<device name>' is not responding
Unable to write to '<address>' on device '<device name>'
Device Specific Messages
Device '<device name>' block request [<start address> to <end address>] responded with exception '<exception response>'
Failure to start Winsock communications
Illegal data address for tag '<tag address>' on device '<device name>'
Illegal data address in block [<start address> to <end address>] on device '<device name>'
Illegal data value for tag '<tag address>' on device '<device name>'
Illegal data value in block [<start address> to <end address>] on device '<device name>'
Illegal function code '<function code (hex)>' in block [<start address> to <end address>] on device '<device name>'
Illegal function code '<hex function code>' for tag '<tag address>' on device '<device name>'
Modbus server device '<device name>' detected a memory parity error
Modbus server device '<device name>' has failed
Modbus server device '<device name>' is busy
Tag '<tag address>' on device '<device name>' responded with exception '<exception code>'
Unable to bind to adapter: '<adapter>'. Connect failed.
Unable to create a socket connection for Device '<device>'
Unexpected response frame received for block [<start address> to <end address>] on device '<device name>'
Unexpected response frame received for tag '<tag address>' on device '<device name>'
Winsock initialization failed (OS Error = <error code>)
Winsock shut down failed (OS Error = <error code>)
Winsock V1.1 or higher must be installed to use the Yaskawa MP Series Ethernet device driver
Hardware Configuration
Hardware Configuration for MPxxxx (218IF Module)
Hardware Configuration for MPxxxxiec
Hardware Configuration MPxxxx (218IF Module) - Ladders
Yaskawa MP Series Serial
Overview
Setup
Channel Properties — General
Channel Properties — Serial Communications
Channel Properties — Ethernet Encapsulation
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Block Sizes
Data Types Description
Address Descriptions
MP Series Address Descriptions
GL Series Address Descriptions
Error Descriptions
Address Validation
Missing address
Device address '<address>' contains a syntax error
Address '<address>' is out of range for the specified device or register
Device address '<address>' is not supported by model '<model name>'
Data Type '<type>' is not valid for device address '<address>'
Device address '<address>' is Read Only
Array size is out of range for address '<address>'
Array support is not available for the specified address: '<address>'
Device Status Messages
Device '<device name>' is not responding
Unable to write to '<address>' on device '<device name>'
Device Specific Messages
Device '<device>' responded with error '<Memobus error code>' (Tag '<tag>', Size '<bytes>')
Bad received length [<start address> to <end address>] on device '<device>'
Bad address in block [<start address> to <end address>] on device '<device>'
Device '<device>' block request [<start address> to <end address>] responded with exception <Memobus error code>
Yokogawa Controller
Overview
Setup
Channel Properties — General
Channel Properties — Serial Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Device Properties for UT37 Series
Device Properties for PCLink Series
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Tag Generation
Automatic Tag Database Generation
Device Properties — Special Data Handling
Device Properties — Request Size Settings
Device Properties — Checksum Settings
Broadcasting
Data Types Description
Default Data Types for Devices Supporting PCLink Protocol
Address Descriptions
UT37 Addressing
UT38 Addressing
UP27 Addressing
UT750 Addressing
Configuration Parameters Addressing for UT750
Control Mode Parameters Addressing for UT750
Loop Parameter Addressing for UT750
Error Status Addressing for UT750
Input Block Addressing for UT750
Loop Mode Status Addressing for UT750
Linearizer Register Addressing for UT750
Control Parametersq for UT750
OP Mode Addressing for UT750
OP Related Parameter Addressing for UT750
Output Block Addressing for UT750
PID Parameters Addressing for UT750
Process Parameters Addressing for UT750
Status Addressing for UT750
Absolute Address Mapping (D0000-D0300) for UT750
Absolute Address Mapping (D0301 - D0700)
Absolute Address Mapping (D0700 - D1100) for UT750
Absolute Address Mapping (D1100 - D1300)
Absolute Address Mapping (D1301 - D1700)
Absolute address Mapping (I0001 - I0701) for UP750
UP750 Addressing
Configuration Parameters Addressing for UP750
Control Mode Addressing for UP750
Loop Function Parameter Addressing for UP750
Error Status Addressing for UP750
Input Block Addressing for UP750
Loop Mode Status Addressing for UP750
Linearizer Registers Addressing for UP750
Control Parameter Addressing for UP750
OP Mode Parameter Addressing for UP750
OP Related Parameter Addressing for UP750
Output Block Addressing for UP750
PID Parameters addressing for UP750
Status Addressing for UP750
Process Parameters Addressing for UP750
Absolute Address Mapping (D0001 - D0300) for UP750
Absolute Address Mapping (D0301 - D0700) for UP750
Absolute Address Mapping (D0701 - D1100) for UP750
Absolute Address Mapping (D1101 - D1300) for UP750
Absolute Address Mapping (D1301 - D1710) for UP750
Absolute Address Mapping (I0001 - I0714) for UP750
UT350/UT320 Addressing
PID Parameter Addressing for UT350 / UT320
Status Addressing for UT350 / UT320
Communication Parameter Addressing for UT350 / UT320
Control Output Parameters Addressing for UT350
OP Mode Parameter Addressing for UT350 / UT320
OP Related Parameter Addressing for UT350 / UT320
PV Input Parameters Addressing for UT350 / UT320
Process Parameters addressing for UT350 / UT320
Setup Parameters Addressing for UT350 / UT320
Absolute Address Mapping (D0001 - D0301) for UT350 / UT320
Absolute Address Mapping (D0301 - D1253) for UT350 / UT320
Absolute Address Mapping (I0001-I0486) for UT350 / UT320
US1000 Addressing
Configuration Parameters Addressing for US1000
Control Mode Parameter Addressing for US1000
OP Related Parameters Addressing for US1000
PID Parameter Addressing for US1000
Process Parameters Addressing for US1000
Setup Parameter Addressing for US1000
Status Addressing for US1000
Absolute Address Mapping (D0001 - D0301) for US1000
Absolute Address Mapping (D0301 - D0700) for US1000
Absolute Address Mapping (D0901 - D1300) for US1000
Absolute Address Mapping (I0001 - I0768) for US1000
UT130/UT150/UT152/UT155/UP150 Addressing
Process Parameters Addressing for UT130 / UT150 / UT152 / UT155 / UP150
Status Addressing for UT130 / UT150 / UT152 / UT155 / UP150
User Area Parameter Addressing for UT130 / UT150 / UT152 / UT155 / UP150
Absolute Address Mapping (D0001 - D0312) for UT130 / UT150 / UT152 / UT155 / UP150
Absolute Address Mapping (I0001-I0051) for UT150 / UT130 / UT152 / UT155 / UP150
UT150L Addressing
Process Parameters Addressing for UT150L
Status Addressing for Ut150L
User Area Parameter Addressing for UT150L
Absolute Address Mapping (D0001 - D0306) for UT150L
Absolute Address Mapping (I0001 - I0051) for UT150L
UT351 Addressing
OP Mode Parameters Addressing for UT351
OP Related Parameters Addressing for UT351
PID Parameters Addressing for UT351
Process Parameters Addressing for UT351
Setup Parameters Addressing for UT351
Communication Parameters Addressing for UT351
Control Output Parameters Addressing for UT351
PV Input Parameters Addressing for UT351
Status Addressing for UT351
Absolute Address Mapping (D0001 - D1253) for UT351
Absolute Address Mapping (I0001 - I0486) for UT351
UT350L Addressing
OP Related Parameters Addressing for UT350L
PID Parameters Addressing for UT350L
Process Parameters Addressing for UT350L
Communication Parameters Addressing for UT350L
Setup Parameters Addressing for UT350L
PV Input Parameters Addressing for UT350L
Status Addressing for UT350L
Absolute Address Mapping (D0001 - D1253) for UT350L
Absolute Address Mapping (I0001 - I0098) for UT350L
UT420 Addressing
OP Related Parameters Addressing for UT420
Process Parameters Addressing for UT420
Setup Parameters Addressing for UT420
PV Input Parameters Addressing for UT420
Status Addressing for UT420
Absolute Address Mapping (D0001 - D1274) for UT420
Absolute Address Mapping (I0001-I0693) for UT420 / UT450
UT450 Addressing
OP Related Parameters Addressing for UT450
Setup Parameters Addressing for UT450
Process Parameters Addressing for UT450
PV Input Parameters Addressing for UT450
Status Addressing for UT450
Absolute Address Mapping (D0001 - D1274) for UT420
Absolute Address Mapping (I0001-I0693) for UT420 / UT450
UT520/UT550 Addressing
Configuration Parameters Addressing for UT520 / UT550
Control Mode Parameters Addressing for UT520 / UT550
Loop Parameters Addressing for UT520
L1 and L2 Mode Parameters Addressing for UT520
Linearizer Registers Addressing for UT520
Control Parameters Addressing for UT520 / UT550
OP Related Parameter Addressing for UT520 / UT550
OP Mode Parameter Addressing for UT520-UT550
PID Parameters Addressing for UT520 / UT550
Error Status Addressing for UT520 / UT550
Status Addressing for UT520 / UT550
Process Parameters Addressing for UT520 / UT550
Absolute Address Mapping (D0001 - D0301) for UT550 / UT520
Absolute Address Mapping (D0301 - D0700) for UT520 / UT550
Absolute Address Mapping (D0701 - D1100) for UT550 / UT520
Absolute Address Mapping (D1101 - D1300) for UT550 / UT520
Absolute Address Mapping (I0001 - I0701) for UT550 / UT520
UP550 Addressing
Configuration Parameters Addressing for UP150
Control Mode Parameters Addressing for UP550
Loop Parameters Addressing for UP550
Error Status Addressing for UP550
L1 and L2 Mode Parameters Addressing for UP550
Linearizer Registers Addressing for UP550
Control Parameters Addressing for UP550
OP Mode Parameter Addressing for UP550
OP Related Parameter Addressing for UP550
PID parameters for UP550
Process Parameters Addressing for UP550
Status Addressing for UP550
Absolute Address Mapping (D0001 - D0300) for UP550
Absolute Address Mapping (D0301 - D0700) for UP550
Absolute Address Mapping (D0701 - D1300) for UP550
Absolute Address Mapping (I0001 - I0714) for UP550
UP350 Addressing
OP Related Parameters Addressing for UP350
PID Parameters Addressing for UP350
Process Parameters Addressing for UP350
Setup Parameters Addressing for UP350
Communication Parameters Addressing for UP350
Control Output Parameters Addressing for UP350
PV Input Parameters Addressing for UP350
Status Addressing for UP350
Absolute Address Mapping (D0001 - D1253) for UP350
Absolute Address Mapping (I0001 - I0513) for UP350
Error Descriptions
Address Validation
Missing address
Device address <address> contains a syntax error
Address <address> is out of range for the specified device or register
Data Type <type> is not valid for device address <address>
Device address <address> is Read Only
Serial Communications
COMn does not exist
Error opening COMn
COMn is in use by another application
Unable to set comm properties on COMn
Communications error on <channel name> [<error mask>]
Device Status Messages
Device <device name> is not responding
Unable to write to <address> on device <device name>
PCLink Specific Errors
Unable to read absolute address <start address> to <last address> from device <Device ID>. EC1 = <error code>
Failed to read tag '%s' for device id %d
Frame received for absolute address <tag address> to <tag address> for device <device id> had checksum error
Frame received for tag <tag address> for device <device id> had checksum error
Yokogawa CX
Overview
Setup
Channel Properties — General
Channel Properties — Ethernet Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Tag Generation
Device Properties — Device Configuration
Optimizing Communications
Data Types Description
Automatic Tag Database Generation
Address Descriptions
CX1006_Addressing
CX1206_Addressing
CX2010_Addressing
CX2020_Addressing
CX2210_Addressing
CX2220_Addressing
CX2410_Addressing
CX2420_Addressing
CX2610_Addressing
CX2620_Addressing
Error Descriptions
Address Validation
Address '<address>' is out of range for the specified device or register
Data Type '<type>' is not valid for device address '<address>'
Device address '<address>' contains a syntax error
Device address '<address>' is Read Only
Missing address
Device Status Messages
Device '<device name>' is not responding
Device '<device name>' login failed. Check username and password
Device '<device name>' login not accepted. Choose username of 'admin' or 'user'
No more logins at this level on device '<device name>'
Unable to write to '<address>' on device '<device name>'
Write allowed for admin level only Device '<device name>', Tag '<address>')
Write allowed for devices with math option only (Device '<device name>', Tag '<address>')
Driver Error Messages
Winsock initialization failed (OS Error = n)
Winsock V1.1 or higher must be installed to use the Yokogawa CX Ethernet device driver
Yokogawa Darwin Ethernet
Overview
Setup
Channel Properties — General
Channel Properties — Ethernet Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Tag Generation
Device Properties — Device Configuration
Optimizing Communications
Data Types Description
Address Descriptions
DA100-1_Addressing
DA100-2_Addressing
DR231 Addressing
DR232 Addressing
DR241 Addressing
DR242 Addressing
DR130 Addressing
DC100-1 Addressing
DC100-2 Addressing
Automatic Tag Database Generation
Error Descriptions
Address Validation
Address '<address>' is out of range for the specified device or register
Data Type '<type>' is not valid for device address '<address>'
Device address '<address>' contains a syntax error
Device address '<address>' is Read Only
Missing address
Device Status Messages
Device '<device name>' is not responding
Unable to write to '<address>' on device '<device name>.'
Driver Error Messages
Winsock initialization failed (OS Error = n)
Winsock V1.1 or higher must be installed to use the Yokogawa Darwin Ethernet device driver
Yokogawa Darwin Serial
Overview
Setup
Channel Properties — General
Channel Properties — Serial Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Tag Generation
Device Properties — Device Configuration
Data Types Description
Address Descriptions
DA100-1_Addressing
DA100-2_Addressing
DR130 Addressing
DR231 Addressing
DR232 Addressing
DR241 Addressing
DR242 Addressing
DC100-1 Addressing
DC100-2 Addressing
Error Descriptions
Address Validation
Address '<address>' is out of range for the specified device or register
Data Type '<type>' is not valid for device address '<address>'
Device address '<address>' contains a syntax error
Device address '<address>' is Read Only
Missing address
The device '<device name>' responded with a NAK to a read request starting at address '<address>'. The requested address may not exist in the device
Serial Communications
Communications error on '<channel name>' [<error mask>]
COMn does not exist
COMn is in use by another application
Error opening COMn
Unable to set comm properties on COMn
Device Status Messages
Device '<device name>' is not responding
Unable to write to '<address>' on device '<device name>.'
Yokogawa DX Ethernet
Overview
Setup
Channel Properties — General
Channel Properties — Ethernet Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Tag Generation
Device Properties — Device Configuration
Device Properties — Redundancy
Optimizing Communications
Data Types Description
Address Descriptions
S120 Addressing for 100 Series
DX102 Addressing
DX104 Addressing
DX106 Addressing
DX112 Addressing
S120 Addressing for 200 Series
DX204 Addressing
DX208 Addressing
DX210 Addressing
DX220 Addressing
DX230 Addressing
S123 Addressing for DX210, DX220, DX230
MV100 Addressing
MV200 Addressing
DX1002 Addressing
DX1004 Addressing
DX1006 Addressing
DX1012 Addressing
DX2004 Addressing
DX2008 Addressing
DX2010 Addressing
DX2020 Addressing
DX2030 Addressing
DX2040 Addressing
DX2048 Addressing
Event Log Messages
Error Descriptions
Address Validation
Missing address
Device address '<address>' contains a syntax error
Address '<address>' is out of range for the specified device or register
Data Type '<type>' is not valid for device address '<address>'
Device address '<address>' is Read Only
Device Status Messages
Detected unsupported model series '<model series>' on device '<device name>'. Using configured model series '<model series>' for communications
Device '<device name>' is not responding
Model series '<model series>' read from device '<device name>' does not match the series of the configured model '<configured model>'. Auto generated tags may not validate
Unable to write to '<address>' on device '<device name>'
Write allowed for admin level only
Write allowed for devices with math option only
Driver Error Messages
Winsock initialization failed (OS Error = n)
Winsock V1.1 or higher must be installed to use the Yokogawa DX Ethernet device driver
Automatic Tag Database Generation Messages
Unable to generate a tag database for device '<device name>'. Reason: Device '<device name>' login failed. Check username and password
Unable to generate a tag database for device '<device name>'. Reason: Device '<device name>' login not accepted
Unable to generate a tag database for device '<device name>'. Reason: Device '<device name>' login failed. No more logins at this user level
Unable to generate a tag database for device '<device name>'. Reason: Device '<device name>' responded with error '<error code>'
Yokogawa DXP
Overview
Setup
Channel Properties — General
Channel Properties — Ethernet Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Tag Generation
Automatic Tag Database Generation
Device Properties — Device Configuration
Optimizing Communications
Data Types Description
Address Descriptions
DXP100_Addressing
DXP200_Addressing
Error Descriptions
Address Validation
Address '<address>' is out of range for the specified device or register
Data Type '<type>' is not valid for device address '<address>'
Device address '<address>' contains a syntax error
Device address '<address>' is Read Only
Missing address
Device Status Messages
Device '<device name>' is not responding
Unable to write to '<address>' on device '<device name>'
Write allowed for admin level only
Write allowed for devices with math option only
Driver Error Messages
Winsock initialization failed (OS Error = n)
Winsock V1.1 or higher must be installed to use the Yokogawa DXP Ethernet device driver
Automatic Tag Database Generation Messages
Unable to generate a tag database for device '<device name>'. Reason: Device '<device name>' login failed. Check username and password
Unable to generate a tag database for device '<device name>'. Reason: Device '<device name>' login failed. No more logins at this user level
Unable to generate a tag database for device '<device name>'. Reason: Device '<device name>' login not accepted. Choose username of 'admin' or 'user'
Unable to generate a tag database for device '<device name>'. Reason: Device '<device name>' responded with error '<error code>'
Yokogawa DX Serial
Overview
Setup
Channel Properties — General
Channel Properties — Serial Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Tag Generation
Device Properties — Device Configuration
Data Types Description
Address Descriptions
DX102 Addressing
DX104 Addressing
DX106 Addressing
DX112 Addressing
DX204 Addressing
DX208 Addressing
DX210 Addressing
DX220 Addressing
DX230 Addressing
MV100 Addressing
MV200 Addressing
Error Descriptions
Address Validation
Address '<address>' is out of range for the specified device or register
Data Type '<type>' is not valid for device address '<address>'
Device address '<address>' contains a syntax error
Device address '<address>' is Read Only
Missing address
Serial Communications
Communications error on '<channel name>' [<error mask>]
COMn does not exist
COMn is in use by another application
Error opening COMn
Unable to set comm parameters on COMn
Device Status Messages
Device '<device name>' is not responding
Unable to write to '<address>' on device '<device name>'
Yokogawa GX Ethernet
Overview
Setup
Channel Properties — General
Channel Properties — Ethernet Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Tag Generation
Device Properties — Device Configuration
Device Properties — Redundancy
Optimizing Communications
Data Types Description
Address Descriptions
Yokogawa HR
Overview
Setup
Channel Properties — General
Channel Properties — Serial Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Tag Generation
Device Properties — Device Configuration
Data Types Description
Address Descriptions
HR2400 (10CH) Addressing
HR2400 (20CH) Addressing
HR2400 (30CH) Addressing
Error Descriptions
Address Validation
Missing address
Device address '<address>' contains a syntax error
Address '<address>' is out of range for the specified device or register
Data Type '<type>' is not valid for device address '<address>'
Device address '<address>' is Read Only
Serial Communications
COMn does not exist
Error opening COMn
COMn is in use by another application
Unable to set comm parameters on COMn
Communications error on '<channel name>' [<error mask>]
Device Status Messages
Device '<device name>' is not responding
Unable to write to '<address>' on device '<device name>'
Yokogawa MW
Overview
Setup
Channel Properties — General
Channel Properties — Ethernet Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Tag Generation
Device Properties — Device Configuration
Optimizing Communications
Data Types Description
MW100 Addressing
Error Descriptions
Address Validation
Address '<address>' is out of range for the specified device or register
Data Type '<type>' is not valid for device address '<address>'
Device address '<address>' contains a syntax error
Device address '<address>' is Read Only
Missing address
Device Status Messages
Device '<device>' login failed. Check username and password
Device '<device>' responded with error '<errnum>' (Tag '<address>')
Device '<device>' responded with error '<error>'
Device '<device>' returned error '2 <Value exceeds setting range>'. (Tag '<address>')
Device '<device name>' is not responding
Device <device name> login failed. No more logins at this user level
Unable to set clock for device '<device>'
Unable to start math for device '<device>'
Unable to start measuring for device '<device>'
Unable to write to '<address>' on device '<device name>'
Driver Error Messages
Winsock initialization failed (OS Error = n)
Winsock V1.1 or higher must be installed to use the Yokogawa MW Ethernet Device Driver
Yokogawa MX
Overview
Setup
Channel Properties — General
Channel Properties — Ethernet Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Tag Generation
Device Properties — Device Configuration
Optimizing Ethernet Communications
Data Types Description
Address Descriptions
Error Descriptions
Address Validation
Address '<address>' is out of range for the specified device or register
Data Type '<type>' is not valid for device address '<address>'
Device address '<address>' contains a syntax error
Device address '<address>' is Read Only
Missing address
Device Status Messages
Detected Yokogawa MX 100 Unit Style '<version>' with '<number of modules>' modules and a total of '<number of channels>' channels on device '<device name>'
Device '<device>' response contains framing errors (Tag '<tag address>')
Device '<device name>' has no FIFO data for channel (Tag '<address>')
Device '<device name>' is not responding
Device '<device name>' responded with error '<error code>' (Tag '<address>', Size '<size>')
Unable to write to '<address>' on device '<device name>'
Driver Error Messages
Winsock initialization failed (OS Error = n)
Winsock V1.1 or higher must be installed to use the Yokogawa MX Ethernet device driver
Yokogawa YS100
Overview
Setup
Channel Properties — General
Channel Properties — Serial Communications
Channel Properties — Write Optimizations
Channel Properties — Advanced
Device Properties — General
Device Properties — Scan Mode
Device Properties — Timing
Device Properties — Auto-Demotion
Device Properties — Tag Generation
Automatic Tag Database Generation
Device Properties — Settings
Data Types Description
Address Descriptions
YS150 Addressing
YS170 Addressing
Error Descriptions
Address Validation
Address <address> is out of range for the specified device or register
Data Type <type> is not valid for device address <address>
Device address <address> contains a syntax error
Device address <address> is not supported by model <model name>.'
Device address <address> is Read Only
Missing address
Serial Communications
Communications error on <channel name> [<error mask>]
COMn does not exist
COMn is in use by another application
Error opening COMn
Unable to set comm parameters on COMn
Device Status Messages
Device <device name> is not responding
Unable to write to <address> on device <device name>.'
YS100 Serial Device Specific Messages
Failed to read static initialization data for device <device name>
No response to watchdog write on device <device name>
Received unexpected response for tag in block <tag name> on device <device name>,
ABB Totalflow Driver
Received unexpected response for tag in block <tag name> on device <device name>,
timing2
SERVERMAIN_TIME_ZONE_SECTION
EFM_GROUP
d1e8871a1310
CommunicationParameters
d1e23055a1310
Addressing
LoginTimeout
DATA_SOURCE_TABLE_SELECTION_GROUP
TIMING_OPTIONS_GROUP
AddressDescriptions
d1e40431a1310
AddressDescriptions_4
d1e64442a1310
d1e66445a1310
AddressDescriptions_1
d1e96052a1310
d1e163758a1310
d1e232841a1310
d1e236940a1310
ProtocolSettings2
d1e267003a1310
d1e267036a1310
CommonIdentification
d1e272067a1310
CommParameters2
ProtocolParms
SlotConfiguration
OpenAddressing
FLC5_Family
d1e293086a1310
Options
ADDRESS_DESCRIPTIONS
LinkSettings2
d1e319333a1310
CIP
DataAccess
d1e339328a1310
d1e345241a1310
NETWORK_INTERFACE_GROUP
d1e351867a1310
DEVICE_ID_GROUP
BLOCKS_GROUP
REDUNDANCY_SETTINGS_GROUP
d1e353994a1310
DRIVER_SETUP_GROUP
d1e362099a1310
DATA_FORMAT_GROUP
d1e364039a1310
d1e364217a1310
d1e364368a1310
d1e364490a1310
d1e364668a1310
d1e366520a1310
d1e372363a1310
d1e374176a1310
d1e374262a1310
d1e374739a1310
d1e375216a1310
d1e375694a1310
d1e382912a1310
COMMUNICATIONS_PARAMETERS_GROUP
STATION_NUMBERS_GROUP
REQUEST_SIZE_GROUP
d1e385999a1310
d1e388173a1310
d1e394010a1310
d1e397129a1310
d1e397313a1310
d1e397961a1310
d1e398666a1310
d1e399324a1310
DL_250_Addressing
d1e400601a1310
d1e401291a1310
d1e401809a1310
d1e402345a1310
d1e402969a1310
d1e403620a1310
d1e404286a1310
d1e406366a1310
d1e411883a1310
LINK_CONFIGURATION_GROUP
COMMUNICATION_SETTINGS_GROUP
DataTypesDescription
H2_EBC_F_Addressing
H4_EBC_F_Addressing
d1e415007a1310
GS_Drive_Addressing_GS3
ErrorDescriptions
d1e427178a1310
d1e432712a1310
d1e435010a1310
TAG_IMPORT_SETTINGS_GROUP
d1e435651a1310
d1e436021a1310
d1e436735a1310
d1e437516a1310
d1e438253a1310
d1e438920a1310
d1e439623a1310
d1e440305a1310
d1e441005a1310
d1e441681a1310
d1e442865a1310
d1e442898a1310
d1e448715a1310
d1e451218a1310
d1e451466a1310
d1e451662a1310
d1e452293a1310
D1_105_Addressing
d1e453643a1310
d1e454283a1310
D2_250_Addressing
D2_260_Addressing
d1e456199a1310
d1e456802a1310
d1e457440a1310
d1e458083a1310
d1e458753a1310
d1e459423a1310
d1e461745a1310
d1e467237a1310
COMMUNICATION_GROUP
DATA_HANDLING_GROUP
TAG_IMPORT_FILE_PATH_GROUP
d1e470175a1310
IDH_DISCOVERYPAGE
d1e481238a1310
Command
d1e481567a1310
COV_Shutdown
Event_Notification
ID37766400
d1e491419a1310
d1e527916a1310
COMMUNICATION_PARAMETERS_GROUP
OPTIONS_GROUP
SYMBOLIC_SETTINGS_GROUP
d1e531499a1310
Local_Port
LOCAL_PORT_GROUP
d1e545717a1310
TIMING_GROUP
d1e545892a1310
Address_Descriptions_2
d1e548562a1310
d1e548609a1310
d1e554112a1310
TCPIP_GROUP
d1e555727a1310
d1e556018a1310
d1e556341a1310
d1e556919a1310
CHANNEL_COMMUNICATION_PARAMETERS_GROUP
d1e561498a1310
ID37766912
DEVICE_GATEWAY_PARAMETERS_SECTION
DEVICE_PLC_USER_CREDENTIALS
TagBrowser
d1e566787a1310
d1e570939a1310
d1e576781a1310
d1e578414a1310
d1e578585a1310
d1e579344a1310
d1e580569a1310
d1e586428a1310
d1e588046a1310
d1e588398a1310
d1e588910a1310
d1e589362a1310
d1e589678a1310
d1e590084a1310
d1e590430a1310
d1e590836a1310
d1e591318a1310
d1e591712a1310
d1e592103a1310
d1e599924a1310
d1e611532a1310
d1e613147a1310
d1e613384a1310
d1e613458a1310
d1e614175a1310
d1e614911a1310
d1e615595a1310
d1e616842a1310
d1e622284a1310
TCP_IP_GROUP
BLOCK_SIZES_GROUP
SETTINGS_GROUP
Addressing_PV_Model
d1e632234a1310
PA_addressing
d1e637677a1310
d1e642877a1310
d1e645441a1310
d1e648846a1310
Driver_Setup
d1e653998a1310
d1e654298a1310
d1e654418a1310
Address_Descriptions_Modbus
ADVANCED_GROUP
d1e708046a1310
d1e747343a1310
d1e749692a1310
d1e756898a1310
NEW
d1e766856a1310
d1e775713a1310
d1e781590a1310
d1e784023a1310
d1e784368a1310
d1e785183a1310
d1e786161a1310
d1e787140a1310
d1e788118a1310
Open_Addressing
d1e797522a1310
d1e802792a1310
d1e807962a1310
d1e809695a1310
d1e810055a1310
d1e810791a1310
d1e811662a1310
d1e812534a1310
d1e813405a1310
d1e814276a1310
d1e818370a1310
d1e826380a1310
d1e828678a1310
d1e852375a1310
d1e854673a1310
d1e875485a1310
d1e877783a1310
d1e898669a1310
d1e900967a1310
d1e918173a1310
d1e924038a1310
d1e925648a1310
d1e925891a1310
d1e925953a1310
d1e926491a1310
d1e927056a1310
d1e928864a1310
d1e935007a1310
d1e936576a1310
d1e936834a1310
d1e937018a1310
d1e937366a1310
d1e937716a1310
d1e938067a1310
d1e938417a1310
d1e938767a1310
d1e939117a1310
d1e939467a1310
d1e939817a1310
d1e940168a1310
d1e940515a1310
d1e940966a1310
d1e941316a1310
Invalid_tag_in_block_starting_at__address__in_device__device_.
d1e943350a1310
d1e943383a1310
d1e948864a1310
Exchange
NameResolution
d1e950628a1310
d1e950937a1310
d1e951530a1310
d1e954631a1310
d1e960045a1310
PLC_SETTINGS_GROUP
d1e964392a1310
d1e964697a1310
d1e964966a1310
d1e966042a1310
d1e966592a1310
d1e967142a1310
d1e967683a1310
d1e968224a1310
d1e968759a1310
d1e969294a1310
d1e969975a1310
d1e970658a1310
d1e971338a1310
d1e972023a1310
d1e972675a1310
d1e973322a1310
d1e974021a1310
d1e974543a1310
d1e976708a1310
Address___address___is_out_of_range_for_the_specified_device_or_register.
Device_address___address___contains_a_syntax_error.
Device___device_name__not_responding.
Unable_to_write_tag___address___on_device___device_name_._
d1e979139a1310
d1e979172a1310
d1e985350a1310
d1e987717a1310
d1e988627a1310
GE_Micro
d1e989357a1310
d1e989845a1310
d1e990328a1310
d1e990807a1310
d1e991286a1310
d1e991763a1310
d1e992240a1310
d1e992719a1310
d1e993197a1310
d1e993674a1310
d1e994147a1310
d1e994624a1310
d1e995101a1310
d1e996117a1310
d1e996614a1310
d1e996669a1310
COMn_does_not_exist.
Error_opening_COMn.
d1e997093a1310
d1e997151a1310
Communications_error_on_COMn___error_mask__
d1e997326a1310
d1e997405a1310
d1e1000992a1310
d1e1001025a1310
d1e1007178a1310
d1e1009536a1310
d1e1009824a1310
d1e1010063a1310
d1e1010648a1310
Channel_Properties_Comm_None
d1e1011621a1310
d1e1012098a1310
d1e1012575a1310
d1e1013052a1310
d1e1013529a1310
d1e1014006a1310
d1e1014484a1310
d1e1014961a1310
d1e1015438a1310
d1e1015915a1310
d1e1016392a1310
d1e1019113a1310
d1e1028669a1310
TCPIPGROUP
d1e1030284a1310
d1e1030770a1310
TAG_IMPORT_GROUP
d1e1031524a1310
d1e1035476a1310
d1e1040954a1310
d1e1043314a1310
d1e1043355a1310
REGISTERS_SECTION
d1e1044194a1310
d1e1050757a1310
d1e1057735a1310
d1e1071952a1310
d1e1073515a1310
COILS_SECTION
Address_Descriptions_Honeywell_UDC
d1e1081921a1310
d1e1084362a1310
d1e1084686a1310
d1e1084821a1310
d1e1085471a1310
d1e1086581a1310
d1e1087689a1310
d1e1088875a1310
d1e1089649a1310
d1e1090423a1310
d1e1091197a1310
d1e1098246a1310
d1e1101203a1310
CONTROL_GROUP
TAG_DATABASE_SETTINGS_GROUP
d1e1102142a1310
Channel_60870
d1e1112862a1310
COMMUNICATIONS_GROUP
d1e1113816a1310
d1e1131156a1310
SETTINGS_GROUP60870
d1e1134107a1310
DEVICE_COMMUNICATIONS_GROUP
EVENT_PLAYBACK_SETTINGS_SECTION
d1e1155893a1310
d1e1160410a1310
d1e1171243a1310
d1e1171959a1310
d1e1179215a1310
DEVICE_TCPIP_GROUP
DEVICE_BLOCK_SIZES_GROUP
d1e1183129a1310
d1e1183170a1310
d1e1188565a1310
d1e1190397a1310
Hints
d1e1193559a1310
d1e1200787a1310
d1e1201570a1310
ADDRESSING_OPTIONS_GROUP
d1e1201833a1310
d1e1213441a1310
DATA_ENCODING_GROUP
FRAMING_GROUP
ERROR_HANDLING_GROUP
CARD_SETTINGS_GROUP
CHANNEL_ITEM_PERSISTENCE_GROUP
d1e1223658a1310
HintsHelpButton
d1e1224169a1310
d1e1232056a1310
d1e1233439a1310
d1e1237414a1310
d1e1239359a1310
DEVICE_SETTINGS_GROUP
d1e1240987a1310
d1e1241257a1310
d1e1241456a1310
d1e1241655a1310
d1e1241855a1310
d1e1242081a1310
d1e1242338a1310
d1e1243637a1310
d1e1249054a1310
MoreBitData
NEtworkParmsSection
Mitsubishi_A_Series_Address_Descriptions
d1e1258896a1310
d1e1281850a1310
d1e1288391a1310
d1e1298400a1310
d1e1298651a1310
FX_Addresses
FX0_Addresses
FX0N_Addresses
FX2N
FX3U_Addresses
d1e1302952a1310
d1e1303739a1310
d1e1304021a1310
d1e1304343a1310
d1e1304769a1310
d1e1305201a1310
FX2N_Addresses
d1e1306075a1310
FXOpen_Addresses
d1e1307923a1310
d1e1308333a1310
d1e1312235a1310
d1e1313353a1310
BridgingSection
FirstWordLowSection
d1e1315419a1310
d1e1315737a1310
d1e1316979a1310
d1e1319541a1310
d1e1325482a1310
d1e1326598a1310
Registers
VIS_Section
DataEncoding
ErrorHandlingSection
d1e1330113a1310
d1e1331535a1310
d1e1331820a1310
d1e1332902a1310
MODBUS_PLUS_ADAPTER_GROUP
d1e1337450a1310
d1e1340034a1310
MODBUS_PLUS_BLOCK_SIZES_GROUP
MODBUS_PLUS_VARIABLE_IMPORT_SETTINGS_GROUP
MODBUS_PLUS_SETTINGS_GROUP
d1e1348715a1310
SettingsGroup
BlockSizesGroup
VISGroup
FramingGroup
ErrorHandlingGroup
d1e1358966a1310
d1e1369511a1310
d1e1371009a1310
d1e1376433a1310
d1e1378764a1310
d1e1379483a1310
d1e1384981a1310
d1e1387279a1310
UnsolicitedGroup
d1e1387545a1310
MODBUS_ETHERNET_ETHERNET_GROUP
d1e1387694a1310
BlockSizes
d1e1389797a1310
SubModelGroup
d1e1395882a1310
d1e1395927a1310
d1e1396185a1310
d1e1396359a1310
d1e1397751a1310
d1e1399912a1310
d1e1406718a1310
d1e1416681a1310
OPTIONAL_CONFIGURATION_SECTION
CHANNEL_TIMING_GROUP
DEVICE_TAG_GENERATION_TOPIC
d1e1421468a1310
d1e1423505a1310
d1e1430839a1310
d1e1433137a1310
d1e1434217a1310
d1e1440806a1310
DATA_SOURCE_ACCESS_METHOD_GROUP
TableSelection
ATGFixed
TimingFixed
DynamicTable
ATGDynamic
TimingDynamic
BUILD_A_QUERY_GROUP
BuildQuery
MISCELLANEOUS_GROUP
d1e1444086a1310
AUTO_TAG_DATABASE_GENERATION_GROUP
QueryMod
STORED_PROCEDURE_SELECTION_GROUP
StoredProcExisting
d1e1454107a1310
d1e1455671a1310
ComParmsGroup2
d1e1475591a1310
d1e1476694a1310
FinsNetworkGroup
RunModeGroup
ComParmsGroup
d1e1479740a1310
d1e1481569a1310
d1e1482817a1310
d1e1484106a1310
d1e1485478a1310
d1e1487169a1310
d1e1489149a1310
d1e1491125a1310
d1e1492647a1310
d1e1494148a1310
d1e1495998a1310
d1e1498081a1310
d1e1499617a1310
d1e1506029a1310
d1e1506302a1310
d1e1506498a1310
d1e1508217a1310
d1e1509399a1310
d1e1510748a1310
d1e1512096a1310
d1e1513694a1310
d1e1515657a1310
d1e1517614a1310
d1e1519103a1310
d1e1520593a1310
d1e1522446a1310
d1e1524474a1310
d1e1525969a1310
d1e1528488a1310
d1e1537222a1310
d1e1538843a1310
C20HDataAreas
d1e1540323a1310
d1e1541371a1310
d1e1548998a1310
d1e1560032a1310
d1e1565881a1310
d1e1567449a1310
d1e1567882a1310
d1e1569156a1310
d1e1570395a1310
d1e1571519a1310
d1e1572705a1310
d1e1573854a1310
d1e1575040a1310
d1e1576259a1310
d1e1577410a1310
d1e1578615a1310
d1e1580932a1310
d1e1582130a1310
d1e1584978a1310
d1e1585017a1310
d1e1588904a1310
d1e1590062a1310
ComParametersSection
d1e1591682a1310
d1e1591949a1310
d1e1592812a1310
d1e1593490a1310
OPC_SERVER_GROUP
CONNECTION_GROUP
OPC_GROUP_GROUP
COMM_PARAMETERS_GROUP
WATCHDOG_GROUP
IMPORT_GROUP
d1e1606008a1310
d1e1633865a1310
d1e1692980a1310
d1e1709941a1310
d1e1723846a1310
d1e1732863a1310
d1e1742027a1310
d1e1754782a1310
d1e1758960a1310
d1e1759008a1310
d1e1765155a1310
SiemensS5_90U_AddressDescriptions
Siemens_S5_95U_Address_Descriptions
Siemens_S5_100U___100_Address_Descriptions
Siemens_S5_100U___101_Address_Descriptions
Siemens_S5_100U___103_Address_Descriptions
Siemens_S5_101U_Address_Descriptions
Siemens_S5_115U___941_Address_Descriptions
Siemens_S5_115U___942_Address_Descriptions
Siemens_S5_115U___943_Address_Descriptions
Siemens_S5_115U___944_Address_Descriptions
Siemens_S5_115U___945_Address_Descriptions
Siemens_S5_135U___921_Address_Descriptions
Siemens_S5_135U___922_Address_Descriptions
Siemens_S5_135U___928_Address_Descriptions
Siemens_S5_155U___946_Address_Descriptions
Siemens_S5_155U___947_Address_Descriptions
d1e1781538a1310
d1e1781593a1310
NetworkParms
d1e1785573a1310
d1e1786689a1310
d1e1788595a1310
d1e1789829a1310
Dev_General
d1e1795110a1310
Device-coms
AddressHints
d1e1805720a1310
d1e1806897a1310
d1e1809249a1310
d1e1810714a1310
d1e1819413a1310
d1e1832177a1310
CommParms
Address_Options
Tag_Import
S7200
S7300
S7400
S71200
S71500
NS7300
NS7400
d1e1861950a1310
d1e1887505a1310
d1e1893027a1310
PROTOCOL_GROUP505
d1e1893983a1310
d1e1894607a1310
d1e1894808a1310
CTI2500_Series
d1e1908510a1310
d1e1908749a1310
d1e1909774a1310
d1e1913486a1310
d1e1915198a1310
d1e1918345a1310
d1e1921429a1310
d1e1921897a1310
d1e1922154a1310
d1e1924062a1310
d1e1924095a1310
d1e1929557a1310
DEVICE_PORT_NUMBER_SECTION
DEVICE_REGISTERS_SECTION
d1e1931434a1310
d1e1931782a1310
d1e1932351a1310
d1e1933536a1310
d1e1939039a1310
d1e1940657a1310
d1e1941427a1310
d1e1942692a1310
Channel_Setup_Discovery_Settings
d1e1950751a1310
d1e1953049a1310
PRIVACY_SECTION
MIB_IMPORT_GROUP
TRAP_INFORM_NOTIFICATIONS_GROUP
NETWORK_ANALYST_GROUP
d1e1954564a1310
d1e1961359a1310
ModemSettings
d1e1966750a1310
d1e1968313a1310
d1e1968485a1310
d1e1968948a1310
d1e1970316a1310
d1e1975254a1310
d1e1975421a1310
d1e1975593a1310
d1e1976593a1310
d1e1982053a1310
d1e1984351a1310
d1e1984402a1310
d1e1984459a1310
d1e1984637a1310
d1e1984928a1310
d1e1985496a1310
d1e1986476a1310
d1e1987495a1310
d1e1993343a1310
d1e1995641a1310
d1e1995698a1310
d1e1995759a1310
d1e1996112a1310
d1e1996680a1310
d1e1997248a1310
d1e1997665a1310
d1e1998111a1310
d1e1998679a1310
d1e1999679a1310
d1e2001138a1310
ADAPTER_GROUP
NETWORK_MANAGER_GROUP
CHANNEL_A_GROUP
HIU_GROUP
MACRO_SETUP_GROUP
d1e2007852a1310
d1e2009801a1310
d1e2010018a1310
d1e2018986a1310
READ_MACRO_GROUP
LINK_MACRO_GROUP
d1e2019904a1310
d1e2031980a1310
d1e2032763a1310
d1e2032848a1310
Address_Descriptions_Header
d1e2060308a1310
d1e2061876a1310
EX100MemoryMap
EX200MemoryMap
EX500MemoryMap
T1MemoryMap
T2MemoryMap
d1e2065136a1310
d1e2067080a1310
d1e2072581a1310
d1e2074144a1310
d1e2074307a1310
d1e2074528a1310
d1e2074614a1310
d1e2075447a1310
d1e2076280a1310
d1e2076918a1310
d1e2077555a1310
CommunicationsParameters
d1e2079266a1310
d1e2084802a1310
d1e2085585a1310
d1e2086895a1310
d1e2087258a1310
PC3AddressDescriptions
PC10G_Address_Descriptions
d1e2094856a1310
d1e2100684a1310
d1e2103165a1310
PC2_Series_Addressing
d1e2103995a1310
d1e2105355a1310
CHANNEL_NETWORK_INTERFACE_GROUP
d1e2110514a1310
DEVICE_CM_CONFIGURATION_GROUP
d1e2112893a1310
DEVICE_TAG_IMPORT_SETTINGS_GROUP
d1e2113454a1310
d1e2113605a1310
d1e2113699a1310
d1e2115811a1310
d1e2116984a1310
d1e2119826a1310
d1e2126680a1310
d1e2126907a1310
d1e2127555a1310
Advanced
ChannelProfile
d1e2132668a1310
DEVICE_TCP_KEEP_ALIVE_INTERVAL
d1e2134175a1310
DEVICE_FILE_NAME
PROFILE_INPUTS_SECTION
d1e2143553a1310
d1e2145851a1310
d1e2145902a1310
DEVICE_SLOT_CONFIGURATION_GROUP
d1e2147337a1310
d1e2149038a1310
d1e2149452a1310
d1e2149909a1310
d1e2150196a1310
d1e2150276a1310
d1e2152225a1310
d1e2161316a1310
Address_Descriptions7
Channel_Setup_Request
Channel_Setup_Timeout
d1e2382884a1310
d1e2383146a1310
TIMEOUT_GROUP
d1e2390924a1310
d1e2391178a1310
d1e2392455a1310
d1e2395574a1310
DeviceID
d1e2397779a1310
d1e2399342a1310
d1e2399400a1310
d1e2399642a1310
MemobusAddressDescriptions
OutputCoils
InputCoils
InternalRegisters
HoldingRegisters
d1e2403200a1310
d1e2404432a1310
d1e2409902a1310
d1e2411465a1310
d1e2411518a1310
d1e2411814a1310
d1e2412114a1310
Address_Descriptions_MPxxxxiec
d1e2412944a1310
d1e2415616a1310
d1e2421605a1310
d1e2423229a1310
MP_AddressDescriptions
d1e2423885a1310
d1e2424242a1310
d1e2425392a1310
d1e2431894a1310
SPECIAL_DATA_HANDLING_GROUP
REQUEST_SIZE_SETTINGS_GROUP
CHECKSUM_SETTINGS_GROUP
Default_Datatype_for_PCLink_protocol_supported_tags
d1e2434880a1310
UT38_Addressing1
d1e2436142a1310
Configuration_Parameter_Addressing_for_UT750
Configuration_Paramete_Addressing_for_UP750
PID_parameters_addressing_for_UT320
Configuration_Parameter_Addressing_for_US1000
Process_parameters_addressing
Process_parameter_addressing_for_UT150L
OP_Mode_parameters_addressing_for_UT351
OP_related_parameters_addressing_for_UT350L
OP_related_parameters_addressing_for_UT420
OP_related_parameters_addressing_for_UT450
Config_parameters_addressing_for_UT5201
Control_Mode_Parameter_for_UP550
OP_Related_parameters_addressing_for_UP350
d1e2689960a1310
d1e2693000a1310
d1e2696043a1310
d1e2700806a1310
d1e2703916a1310
d1e2707025a1310
d1e2711836a1310
d1e2716647a1310
d1e2721470a1310
d1e2726293a1310
d1e2731117a1310
d1e2742681a1310
DEVICE_CONFIGURATION_GROUP
d1e2745258a1310
d1e2745616a1310
d1e2747734a1310
d1e2749886a1310
d1e2751942a1310
d1e2753997a1310
d1e2756052a1310
d1e2758107a1310
d1e2760162a1310
d1e2762217a1310
d1e2764447a1310
d1e2771226a1310
d1e2773524a1310
d1e2773661a1310
d1e2773987a1310
d1e2775745a1310
d1e2777536a1310
d1e2779229a1310
d1e2780921a1310
d1e2782613a1310
d1e2784305a1310
d1e2785997a1310
d1e2787689a1310
d1e2789381a1310
d1e2796038a1310
d1e2798336a1310
Redundancy
d1e2798772a1310
DX100_S120_Addressing
d1e2802264a1310
d1e2804784a1310
d1e2807305a1310
d1e2809825a1310
DX200_S120_Addressing
d1e2815456a1310
d1e2817982a1310
d1e2820502a1310
d1e2823023a1310
d1e2825543a1310
DX200_S123_Addressing
d1e2831669a1310
d1e2833924a1310
d1e2836336a1310
d1e2839122a1310
d1e2841900a1310
d1e2844678a1310
d1e2847456a1310
d1e2851165a1310
d1e2854874a1310
d1e2858584a1310
d1e2862293a1310
d1e2866002a1310
d1e2869711a1310
d1e2875835a1310
d1e2881316a1310
d1e2883773a1310
d1e2884116a1310
d1e2884353a1310
d1e2886315a1310
d1e2888177a1310
d1e2895335a1310
d1e2897633a1310
d1e2898156a1310
d1e2900026a1310
d1e2901893a1310
d1e2903761a1310
d1e2905628a1310
d1e2907495a1310
d1e2909362a1310
d1e2913091a1310
d1e2914959a1310
d1e2916900a1310
d1e2925382a1310
DEVICE_CONFIGURATION_GROUPp
d1e2927776a1310
d1e2928008a1310
SyntaxError4tagaddress
d1e2937170a1310
d1e2939468a1310
HR2400_10CH_Addressing
HR2400_20CH_Addressing
HR2400_30CH_Addressing
d1e2950051a1310
d1e2952349a1310
MX100_Addressing
d1e2956646a1310
d1e2962092a1310
GENERAL_SECTION
d1e2964574a1310
d1e2966192a1310
d1e2967382a1310
d1e2973223a1310
d1e2975571a1310
d1e2975640a1310
d1e2975875a1310
d1e2978605a1310
d1e2981335a1310