Configuration API — Slot Configuration
Given this Example Slot Configuration:
Slot 1: 1746-OV32 32 Output [Trans] (Sink) 10/50 VDC
Slot 2: 1746-I*16 Any 16 pt Discrete Input Module
Slot 3: <No Module>
Slot 4: 0000-Generic Module [1 Input Word, 2 Output Words]
Slot 5: 1746-NT8 Analog 8 Ch Thermocouple Input
Slot 6 – 30: <No Module>
Configure the Slots with the API:
"controllogix_ethernet.DEVICE_SLOT_CONFIGURATION": { "controllogix_ethernet.DEVICE_SLOT_CONFIGURATION_MODULE": [ 30, 1, 255, 62, 76, 255, 255, 255, 255, 255, 255, 255, 255, 255, 255, 255, 255, 255, 255, 255, 255, 255, 255, 255, 255, 255, 255, 255, 255, 255 ], "controllogix_ethernet.DEVICE_SLOT_CONFIGURATION_INPUT_WORDS": [ 0, 1, 0, 1, 8, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0 ], "controllogix_ethernet.DEVICE_SLOT_CONFIGURATION_OUTPUT_WORDS": [ 2, 0, 0, 2, 8, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0 ]