Address Type
|
Format
|
Range
|
Data Types
|
Access
|
|---|---|---|---|---|
|
Process Value of Channel
|
CHxx or CHxx.PV
|
01-20
|
Double, Float
|
Read Only
|
|
Alarm Summary of Channel
|
CHxx.Alarm
|
01-20
|
DWord, Short, Word, Byte
|
Read Only
|
|
Alarm Level1 Status of Channel
|
CHxx.Alarm1
|
01-20
|
Short, Word, Byte
|
Read Only
|
|
Alarm Level2 Status of Channel
|
CHxx.Alarm2
|
01-20
|
Short, Word, Byte
|
Read Only
|
|
Alarm Level3 Status of Channel
|
CHxx.Alarm3
|
01-20
|
Short, Word, Byte
|
Read Only
|
|
Alarm Level4 Status of Channel
|
CHxx.Alarm4
|
01-20
|
Short, Word, Byte
|
Read Only
|
|
Set and Read Level1 Alarm Setpoint
|
CHxx.ASP1
|
01-20
|
Double, Float
|
Read / Write
|
|
Set and Read Level2 Alarm Setpoint
|
CHxx.ASP2
|
01-20
|
Double, Float
|
Read / Write
|
|
Set and Read Level3 Alarm Setpoint
|
CHxx.ASP3
|
01-20
|
Double, Float
|
Read / Write
|
|
Set and Read Level4 Alarm Setpoint
|
CHxx.ASP4
|
01-20
|
Double, Float
|
Read / Write
|
|
Upper Scale Value of Channel*
|
CHxx.scale_Hi
|
01-20
|
Double, Float
|
Read Only
|
|
Lower Scale Value of Channel*
|
CHxx.scale_Lo
|
01-20
|
Double, Float
|
Read Only
|
|
Unit String of Channel*
|
CHxx.unit
|
01-20
|
String
|
Read Only
|
|
Tagname of Channel*
|
CHxx.tag
|
01-20
|
String
|
Read Only
|
|
Status of Channel*
|
CHxx.status
|
01-20
|
String
|
Read Only
|
|
Precision of Channel*
|
CHxx.Precision
|
01-20
|
Short, Word, Byte
|
Read Only
|
|
Lowest Measuring Channel*
|
CH.Low
|
|
Short, Word, Byte
|
Read Only
|
|
Highest Measuring Channel*
|
CH.High
|
|
Short, Word, Byte
|
Read Only
|
|
Address Type
|
Format
|
Range
|
Data Types
|
Access
|
|---|---|---|---|---|
|
Process Value of Internal Loop
|
LPxx or LPxx.PV
|
01-06
|
Double, Float
|
Read Only
|
|
Setpoint Value of Internal Loop for current SP number
|
LPxx.SP
|
01-06
|
Double, Float
|
Read / Write
|
|
Setpoint Value of Internal Loop for specified SP number
|
LPxx.SP.n
|
xx=01-06
n=1-8
|
Double, Float
|
Read / Write
|
|
Current SP number for Internal Loop
|
LPxx.SP.Num
|
01-06
|
Short, Word,
|
Read / Write
|
|
Output Value of Internal Loop
|
LPxx.OUT
|
01-06
|
Double, Float
|
Read / Write
|
|
Alarm Summary of Internal Loop
|
LPxx.Alarm
|
01-06
|
DWord, Short, Word, Byte
|
Read Only
|
|
Alarm Level1 Status of Internal Loop
|
LPxx.Alarm1
|
01-06
|
Short, Word, Byte
|
Read Only
|
|
Alarm Level2 Status of Internal Loop
|
LPxx.Alarm2
|
01-06
|
Short, Word, Byte
|
Read Only
|
|
Alarm Level3 Status of Internal Loop
|
LPxx.Alarm3
|
01-06
|
Short, Word, Byte
|
Read Only
|
|
Alarm Level4 Status of Internal Loop
|
LPxx.Alarm4
|
01-06
|
Short, Word, Byte
|
Read Only
|
|
Set and Read Level1 Alarm Setpoint
|
LPxx.ASP1
|
01-06
|
Double, Float
|
Read / Write
|
|
Set and Read Level2 Alarm Setpoint
|
LPxx.ASP2
|
01-06
|
Double, Float
|
Read / Write
|
|
Set and Read Level3 Alarm Setpoint
|
LPxx.ASP3
|
01-06
|
Double, Float
|
Read / Write
|
|
Set and Read Level4 Alarm Setpoint
|
LPxx.ASP4
|
01-06
|
Double, Float
|
Read / Write
|
|
Set and Read Level1 Alarm
Setpoint of specified PID#
|
LPxx.ASP1.n
|
xx=01-06
n=1-8
|
Double, Float
|
Read / Write
|
|
Set and Read Level2 Alarm
Setpoint of specified PID#
|
LPxx.ASP2.n
|
xx=01-06
n=1-8
|
Double, Float
|
Read / Write
|
|
Set and Read Level3 Alarm
Setpoint of specified PID#
|
LPxx.ASP3.n
|
xx=01-06
n=1-8
|
Double, Float
|
Read / Write
|
|
Set and Read Level4 Alarm
Setpoint of specified PID#
|
LPxx.ASP4.n
|
xx=01-06
n=1-8
|
Double, Float
|
Read / Write
|
|
Upper Scale Value of Internal Loop*
|
LPxx.scale_Hi
|
01-06
|
Double, Float
|
Read Only
|
|
Lower Scale Value of Internal Loop*
|
LPxx.scale_Lo
|
01-06
|
Double, Float
|
Read Only
|
|
Unit String of Internal Loop (PV)*
|
LPxx.unit or LPxx.PV.unit
|
01-06
|
String
|
Read Only
|
|
Unit String of Internal Loop SP*
|
LPxx.SP.unit
|
01-06
|
String
|
Read Only
|
|
Unit String of Internal Loop OUT*
|
LPxx.OUT.unit
|
01-06
|
String
|
Read Only
|
|
Tagname of Internal Loop*
|
LPxx.tag
|
01-06
|
String
|
Read Only
|
|
Tagname of Internal Loop PV*
|
LPxx.PV.tag
|
01-06
|
String
|
Read Only
|
|
Tagname of Internal Loop SP*
|
LPxx.SP.tag
|
01-06
|
String
|
Read Only
|
|
Tagname of Internal Loop OUT*
|
LPxx.OUT.tag
|
01-06
|
String
|
Read Only
|
|
Status of Internal Loop (PV)*
|
LPxx.status or LPxx.PV.status
|
01-06
|
String
|
Read Only
|
|
Status of Internal Loop SP*
|
LPxx.SP.status
|
01-06
|
String
|
Read Only
|
|
Status of Internal Loop OUT*
|
LPxx.OUT.status
|
01-06
|
String
|
Read Only
|
|
Precision of Internal Loop (PV)*
|
LPxx.Precision or LPxx.PV.Precision
|
01-06
|
Short, Word, Byte
|
Read Only
|
|
Precision of Internal Loop SP*
|
LPxx.SP.Precision
|
01-06
|
Short, Word, Byte
|
Read Only
|
|
Precision of Internal Loop OUT*
|
LPxx.OUT.Precision
|
01-06
|
Short, Word, Byte
|
Read Only
|
|
Proportional band value of Internal Loop for current PID number
|
LPxx.PID.P
|
01-06
|
Double, Float
|
Read / Write
|
|
Proportional band value of Internal Loop for specified PID number
|
LPxx.PID.P.n
|
xx=01-06
n=1-8
|
Double, Float
|
Read / Write
|
|
Integral time value of Internal Loop for current PID number
|
LPxx.PID.I
|
01-06
|
Double, Float
|
Read / Write
|
|
Integral time value of Internal Loop for specified PID number
|
LPxx.PID.I.n
|
xx=01-06
n=1-8
|
Double, Float
|
Read / Write
|
|
Derivative time value of Internal Loop for current PID number
|
LPxx.PID.D
|
01-06
|
Double, Float
|
Read / Write
|
|
Derivative time value of Internal Loop for specified PID number
|
LPxx.PID.D.n
|
xx=01-06
n=1-8
|
Double, Float
|
Read / Write
|
|
Current PID number for Internal Loop
|
LPxx.PID.Num
|
01-06
|
Short, Word, Byte
|
Read Only
|
|
Set and Read Run/Stop
(0=Stop, 1=Run)
|
LPxx.RUN
|
01-06
|
Short, Word, Byte
|
Read / Write
|
|
Set and Read Remote/Local
(0=Local, 1=Remote)
|
LPxx.Remote
|
01-06
|
Short, Word, Byte
|
Read / Write
|
|
Set and Read auto/manual/cascade
(0=Auto, 1=Manual, 2=Cascade)
|
LPxx.Mode
|
01-06
|
Short, Word, Byte
|
Read / Write
|
|
Lowest Internal Loop Number*
|
LP.Low
|
|
Short, Word, Byte
|
Read Only
|
|
Highest Internal Loop Number*
|
LP.High
|
|
Short, Word, Byte
|
Read Only
|
|
Ramp Up Rate**
|
LPxx.RUR
xx=loop number
|
01-06
|
Double, Float
|
Read / Write
|
|
Ramp Down Rate**
|
LPxx.RDR
xx=loop number
|
01-06
|
Double, Float
|
Read / Write
|
|
Address Type
|
Format
|
Range
|
Data Types
|
Access
|
|---|---|---|---|---|
|
Process Value of External Loop
|
LPExx or LPExx.PV
|
01-16
|
Double, Float
|
Read Only
|
|
Setpoint Value of External Loop
|
LPExx.SP
|
01-16
|
Double, Float
|
Read / Write
|
|
Output Value of External Loop
|
LPExx.OUT
|
01-16
|
Double, Float
|
Read / Write
|
|
Alarm Summary of External Loop
|
LPExx.Alarm
|
01-16
|
DWord, Short, Word, Byte
|
Read Only
|
|
Alarm Level1 Status of External Loop
|
LPExx.Alarm1
|
01-16
|
Short, Word, Byte
|
Read Only
|
|
Alarm Level2 Status of External Loop
|
LPExx.Alarm2
|
01-16
|
Short, Word, Byte
|
Read Only
|
|
Alarm Level3 Status of External Loop
|
LPExx.Alarm3
|
01-16
|
Short, Word, Byte
|
Read Only
|
|
Alarm Level4 Status of External Loop
|
LPExx.Alarm4
|
01-16
|
Short, Word, Byte
|
Read Only
|
|
Upper Scale Value of External Loop*
|
LPExx.scale_Hi
|
01-16
|
Double, Float
|
Read Only
|
|
Lower Scale Value of External Loop*
|
LPExx.scale_Lo
|
01-16
|
Double, Float
|
Read Only
|
|
Unit String of External Loop (PV)*
|
LPExx.unit or LPExx.PV.unit
|
01-16
|
String
|
Read Only
|
|
Unit String of External Loop SP*
|
LPExx.SP.unit
|
01-16
|
String
|
Read Only
|
|
Unit String of External Loop OUT*
|
LPExx.OUT.unit
|
01-16
|
String
|
Read Only
|
|
Tagname of External Loop*
|
LPExx.tag
|
01-16
|
String
|
Read Only
|
|
Tagname of External Loop PV*
|
LPExx.PV.tag
|
01-16
|
String
|
Read Only
|
|
Tagname of External Loop SP*
|
LPExx.SP.tag
|
01-16
|
String
|
Read Only
|
|
Tagname of External Loop OUT*
|
LPExx.OUT.tag
|
01-16
|
String
|
Read Only
|
|
Status of External Loop (PV)*
|
LPExx.status or LPExx.PV.status
|
01-16
|
String
|
Read Only
|
|
Status of External Loop SP*
|
LPExx.SP.status
|
01-16
|
String
|
Read Only
|
|
Status of External Loop OUT*
|
LPExx.OUT.status
|
01-16
|
String
|
Read Only
|
|
Precision of External Loop (PV)*
|
LPExx.Precision or LPExx.PV.Precision
|
01-16
|
Short, Word, Byte
|
Read Only
|
|
Precision of External Loop*
|
LPExx.SP.Precision
|
01-16
|
Short, Word, Byte
|
Read Only
|
|
Precision of External Loop*
|
LPExx.OUT.Precision
|
01-16
|
Short, Word, Byte
|
Read Only
|
|
Set and Read auto/manual/cascade
(0=Auto, 1=Manual, 2=Cascade)
|
LPExx.MODE
|
01-02
|
Short, Word, Byte
|
Read / Write
|
|
Lowest External Loop Number*
|
LPE.Low
|
|
Short, Word, Byte
|
Read Only
|
|
Highest External Loop Number*
|
LPE.High
|
|
Short, Word, Byte
|
Read Only
|
|
Address Type
|
Format
|
Range
|
Data Types
|
Access
|
|---|---|---|---|---|
|
Process Value of Math Channel
|
CHxx or CHxx.PV
|
31-60
|
Double, Float
|
Read Only
|
|
Alarm Summary of Math Channel
|
CHxx.Alarm
|
31-60
|
DWord, Short, Word, Byte
|
Read Only
|
|
Alarm Level1 Status of Math Channel
|
CHxx.Alarm1
|
31-60
|
Short, Word, Byte
|
Read Only
|
|
Alarm Level2 Status of Math Channel
|
CHxx.Alarm2
|
31-60
|
Short, Word, Byte
|
Read Only
|
|
Alarm Level3 Status of Math Channel
|
CHxx.Alarm3
|
31-60
|
Short, Word, Byte
|
Read Only
|
|
Alarm Level4 Status of Math Channel
|
CHxx.Alarm4
|
31-60
|
Short, Word, Byte
|
Read Only
|
|
Set and Read Level1 Alarm Setpoint
|
CHxx.ASP1
|
31-60
|
Double, Float
|
Read / Write
|
|
Set and Read Level2 Alarm Setpoint
|
CHxx.ASP2
|
31-60
|
Double, Float
|
Read / Write
|
|
Set and Read Level3 Alarm Setpoint
|
CHxx.ASP3
|
31-60
|
Double, Float
|
Read / Write
|
|
Set and Read Level4 Alarm Setpoint
|
CHxx.ASP4
|
31-60
|
Double, Float
|
Read / Write
|
|
Upper Scale Value of Math Channel*
|
CHxx.scale_Hi
|
31-60
|
Double, Float
|
Read Only
|
|
Lower Scale Value of Math Channel*
|
CHxx.scale_Lo
|
31-60
|
Double, Float
|
Read Only
|
|
Unit String of Math Channel*
|
CHxx.unit
|
31-60
|
String
|
Read Only
|
|
Tagname of Math Channel*
|
CHxx.tag
|
31-60
|
String
|
Read Only
|
|
Status of Math Channel*
|
CHxx.status
|
31-60
|
String
|
Read Only
|
|
Precision of Math Channel*
|
CHxx.Precision
|
31-60
|
Short, Word, Byte
|
Read Only
|
|
Lowest Math Channel*
|
CHA.Low
|
|
Short, Word, Byte
|
Read Only
|
|
Highest Math Channel*
|
CHA.High
|
|
Short, Word, Byte
|
Read Only
|
|
Address Type
|
Format
|
Range
|
Data Types
|
Access
|
|---|---|---|---|---|
|
Control Digital Inputs
|
DI
|
DI001-DI006
|
Boolean
|
Read Only
|
|
Control Digital Outputs
|
DO
|
DO001-DO006
|
Boolean
|
Read / Write
|
|
Expansion Digital Inputs
|
RI
|
RI001-RI012
|
Boolean
|
Read / Write
|
|
Expansion Digital Outputs
|
Read Only
|
RO001-RO012
|
Boolean
|
Read / Write
|
|
Internal Switches
|
SW
|
SW001-SW036
|
Boolean
|
Read / Write
|
|
Address Type
|
Format
|
Range
|
Data Types
|
Access
|
|---|---|---|---|---|
|
Administrator Level
|
Admin
|
|
Boolean
|
Read Only
|
|
Date of Last Data
|
Date
|
|
String
|
Read Only
|
|
Time of Last Data
|
Time
|
|
String
|
Read Only
|
|
Model Name of Device
|
Model
|
|
String
|
Read Only
|
|
Host Name of Device
|
Hostname
|
|
String
|
Read Only
|
|
Serial Number of Device
|
SerialNumber
|
|
String
|
Read Only
|
|
IP Address of Device
|
IP
|
|
String
|
Read Only
|
|
Math Communication Data
|
CDxx
|
01-30
|
Float
|
Write Only
|
|
Control Math Execution
|
MathControl
|
|
Short, Word, Byte
|
Write Only
|
|
Reset Alarms
|
AlarmReset
|
|
Boolean
|
Write Only
|
|
Control Command and Response
|
Command
|
|
String
|
Read / Write
|
|
Previous Screen
|
PreScreen
|
|
Boolean
|
Write Only
|
|
Direct Reloading of Configuration
|
Reset
|
|
Boolean
|
Write Only
|
|
SetTime*
|
Tag
|
|
Boolean
|
Write Only
|
Use caution when performing write operations using the Command address.
Note: The actual number of addresses available for each type depends on the configuration of the Yokogawa device. If the driver finds that an address is not present in the device at Runtime, the driver will post an error message and remove the tag from its scan list.