Linking FRACAS Data to a Part
As described in Parts Linked to FRACAS-Calculated Failure Rates, when the FRACAS module is also in use, you can link the FRACAS-calculated failure rate for the part to use it in the prediction.
1. In the System Tree Items table or Parts Table, select the part to link to a FRACAS-calculated failure rate. This part must be assigned a part classification of General.
2. Select Edit > Link Data. The Link Data window opens.
3. For Data Source, select FRACAS. This makes System Tree Item available. If multiple configurations exist, Configuration also becomes available.
* 
The labels for table selections use the singular names assigned to tables in the Table Settings pane in the Project Properties window. For more information, see Specifying Table Settings.
4. Select the part with the FRACAS-calculated failure rate to link and click OK to create the data link.
The Prediction Data pane for the linked part displays a Linked to FRACAS message and Failure Rate, which is display-only. Once prediction calculations run, the last FRACAS-calculated failure rate for the linked part is shown in this field.
For information about managing data links, see Data Link How-Tos. Additionally, you can link the failure rate that the FRACAS module has calculated for an assembly to the assembly. For more information, see Linking FRACAS Data to an Assembly.