|
You can customize the table view to display the extended data and department attributes associated with a part. However, only the unique attributes associated with the extended data and department data objects are displayed. The attributes with the same names within enterprise data, plant data, or department data for a part are not available when customizing the table view. For more information, see Customizing Table Views.
|
Structure Pane Task Tool bars
|
||
---|---|---|
Icon
|
Action
|
Description
|
Editing
|
Use to add parts to the selected assembly, or edit the selected part.
The Editing action can also be used to perform BOM transformation actions, such as duplicating a part or assembly, or updating an alternate BOM.
|
|
Version Control
|
Use to checkin and checkout parts or assemblies.
|
|
Clipboard
|
Allows you to cut, copy, and paste objects in the system.
|
|
Viewing
|
Allows you to modify the existing display so that you can easily work with selected objects, or display certain types of objects, such as extended data.
• Highlight Selected Rows:
Highlights the selected parts in the structure pane, for easier viewing when multiple parts have been selected in a large assembly.
• Clear All Highlighted Rows:
Selects the equivalent part of the selected part in the opposing structure pane.
• Expand by:
Opens a window where you can enter the number of levels (1–12) by which you want to expand selected assembly.
• Show/Hide Specific Information:
Use to select the information to display.
|
|
New/Add
|
Use to perform BOM transformation actions, such as new downstream parts, BOMs, or branches, and to add extended data.
|
|
Filter
|
Use to view or change the Path Filters in an Associative Structure Browser.
|
|
Tools
|
Use to view selected parts in either the upstream or downstream display, or in Creo View. You can also use this action to select an existing equivalent part in the other view.
|
|
Refresh
|
Updates the structure of the selected object according to the filter.
|
|
Table Views
|
Use to customize a Table View.
|
Middle Pane Tool bar
|
||||
---|---|---|---|---|
Icon
|
Action
|
Description
|
||
Set Configuration Specification
|
Lets you directly access and modify configuration specification for upstream and downstream views, in place of Edit Filter.
|
|||
Detect Discrepancies
|
Detects discrepancies in BOM Transformer.
|
|||
Review and Resolve Discrepancies
|
Reviews and resolves discrepancies in BOM Transformer.
|
|||
Synchronize Structures
|
Detects discrepancies between the first-level equivalent parts in upstream and downstream structures based on the criteria specified in the preference Structure Synchronization Criteria. For more information, see Synchronizing Upstream and Downstream Structures.
|
|||
Update Status Indicators
|
Updates the Downstream Equivalent Status, Downstream Equivalent Consumption Status, Upstream Equivalent Status, and Upstream Equivalent Consumption Status columns in the BOM Transformer. For more information, see Equivalent Usages.
|
|||
Reconciliation Assistance
|
Reconciles differences between upstream parts and downstream parts.
|
|||
Smart Collection
|
Creates and edits a smart collection. You can also use it to revert to a smart collection and disable a smart collection.
|
|||
Build Structure Cache
|
||||
Generate Downstream Structure
|
Generates downstream structure from an upstream structure based on a custom logic. For more information on the action, see Generating Downstream Structure.
|
|||
Create Equivalent Link
|
Creates an equivalent link between the part selected in the upstream structure pane, and the part selected in the downstream structure pane.
|
|||
Create Equivalent Usage Link
Create Equivalent Occurrence Link
|
In the usage mode, creates an equivalent usage link between the part selected in the upstream structure pane and the part selected in the downstream structure pane.
In the occurrence mode, creates an equivalent occurrence link between the part selected in the upstream structure pane and the part selected in the downstream structure pane.
|
|||
Synchronize Structure Associativity
|
Updates a downstream BOM structure with the latest information from the upstream BOM to solve basic discrepancies between structures.
The action is hidden by default. You can enable the action by setting the value of the property com.ptc.windchill.associativity.enableSSAAction to true. This property is available in the <WT_HOME>/codebase/com/ptc/core/foundation/associativity/xconfs/associativity.properties.xconf/associativity.properties.xconf file.
The following synchronizations are performed:
• Update quantities for all parts in the downstream BOM based on the quantities in the upstream BOM.
• Add and remove parts in the downstream BOM that have been added or removed from the upstream BOM.
• Propagate options and variants from upstream parts to equivalent downstream parts. To change this default behavior, set the Propagate options and variants preference to no.
A message listing identified changes confirms whether you want to proceed.
|
|||
Update Quantity and Usage Attributes
|
Updates a downstream BOM with the usage quantity and usage attributes of an equivalent upstream object. Both the selected upstream and downstream objects must be equivalent.
|
|||
Update Position
|
Updates the “out-of-position” status for the selected part occurrence based on the current position of the upstream equivalent. Alternatively, you can right-click an occurrence and select Update Position.
|
|||
Update Assigned Expressions
|
Propagates option sets and assigned expressions from the selected upstream object to the selected downstream object.
|
|||
Show Occurrences and Hide Occurrences
|
When selected displays each occurrence of a part as a separate object. If hidden, the number of occurrences of a part can be determined by the Quantity column. A BOM Transformer session, by default, opens in usage mode. Click to switch to occurrence mode. |
|||
New Downstream Branch Variant
|
Creates a new iteration at a new specified downstream branch, and transforms the selected upstream iteration into the new downstream iteration. The resulting new downstream iteration shares a master with the selected upstream iteration.
For more information, refer Adding Parts with Associative BOM Links and Implicit Replacement of Parts.
|
|||
New Downstream Part Variant
|
Creates a new part at a specified branch, and transforms the selected upstream part iteration into the new downstream part.
For more information, refer Adding Parts with Associative BOM Links and Implicit Replacement of Parts.
|
|||
Assemble As
|
Copies an upstream part and pastes it in the downstream BOM. It also creates an equivalent link between the upstream part and downstream part. BOM gets iterated.
|