DPM Administration > Configuring Bottleneck Analysis > Configuring Bottleneck Analysis with Work Center Demand
Configuring Bottleneck Analysis with Work Center Demand
If you know the total demand for your work centers, you can configure bottleneck analysis for a demand window using manually entered work center demand. In this configuration scenario, DPM calculates the TAKT for each work center based on the total demand value that you provide, or you can manually the enter the TAKT values.
To configure a demand window that calculates bottleneck impact using the total demand that is specified on each work center, complete the following steps:
1. In Site Demand, select a site and create a demand window. For the Demand Setting, select Set on Work Centers.
2. In Equipment List, navigate to a work center in the same site for which the demand window was created.
4. Optionally, on the Demand Settings tab, edit the TAKT value for the demand window.
5. Repeat steps 2 through 4 on each work center with demand for this demand window.
Was this helpful?