Property
|
Description
|
---|---|
Font
|
The font for the text.
|
Size
|
The point size for the text.
|
Bold
|
When selected, the text appears in bold type.
|
Italic
|
When selected, the text appears in italic type.
|
Show vote text
|
Indicates whether to show the vote text for a junction with redundancy specified. The vote text refers to the m::n label, where m is the number of units required for system operation and n is the total number of units in the system. This checkbox is not shown for the start node. When this checkbox is selected, the vote text is shown. For standby junctions, the suffix so (for standby operation) is appended to the vote text.
|
Show description
|
Indicates whether to display the description entered on the General page in the text box for the junction. When this checkbox is selected, the description is shown. For more information, see General Page.
|
Text on
|
Specifies where the text is to appear in relationship to the junction. Choices are Top, Bottom, Left, and Right. The default is Bottom.
|