Parameter
|
Type
|
Description
|
||
---|---|---|---|---|
Base Failure Rate
|
Real (Failures/Million Cycles). Used in Lambda b calculation.
|
The base or manufacturer-supplied failure rate entered is used to determine a calculated failure rate. The failure rate is calculated given from the equation Lambda b = 1E6 / N where N is the number of cycles to failure at the material endurance limit.
|
||
Tensile Strength
|
Real (kpsi). Used in Cf calculation.
|
The tensile strength of the shaft material. For more information, see Tensile Strength Values for Shafts.
|
||
Filter Size
|
Real (microns). Used in Ccp calculation.
|
The system filter size in microns.
|
||
Flow Rate - Actual
|
Real (Gallons/Minute). Used in Ctlf calculation.
|
The actual flow in gallons/minute.
|
||
Max Specified Flow
|
Real (Gallons/Minute). Used in Ctlf calculation.
|
The maximum pump specification flow in gallons/minute.
|
||
Finish
|
Choice List. Used in Cf calculation.
|
The appropriate type of surface finish. Choices include Polished, Ground, and more.
|
||
Casing Type
|
Choice List. Used in Ctlf calculation.
|
The correct pump casing type. Choices are:
• Ordinary Volute
• Modified Concentric
• Double Volute
|
||
Unbalanced Force
|
Real (lb). Used in Cdy calculation.
|
The force created from an unequal distribution of forces on the pump shaft from varying fluid pressures.
|
||
Modulus of Elasticity
|
Real (psi). Used in Cdy calculation.
|
The modulus of elasticity in psi.
|
||
Moment of Inertia N
|
Real (in). Used in Cdy calculation.
|
For area N, the moment of inertia in inches.
|
||
Moment of Inertia M
|
Real (in). Used in Cdy calculation.
|
For area M, the moment of inertia in inches.
|
||
Moment of Inertia L
|
Real (in). Used in Cdy calculation.
|
For area L, the moment of inertia in inches.
|
||
Moment of Inertia X
|
Real (in). Used in Cdy calculation.
|
For area X, the moment of inertia in inches.
|
||
N
|
Real (in). Used in Cdy calculation.
|
An area used in measuring shaft deflection.
|
||
M
|
Real (in). Used in Cdy calculation.
|
An area used in measuring shaft deflection.
|
||
L
|
Real (in). Used in Cdy calculation.
|
An area used in measuring shaft deflection.
|
||
X
|
Real (in). Used in Cdy calculation.
|
An area used in measuring shaft deflection.
|
||
Temperature Rise
|
Real (Degrees C). Used in Ct calculation.
|
The temperature rise from the ambient subassembly temperature to this component. The temperature rise plus the ambient temperature is equal to the operating temperature of the device.
|
||
Cycles/Hour
|
Real
|
The number of cycles/hour. This is required to convert failure ratings from failures/cycle to failures/hour.
|
||
[Derating Parameters]
|
---
|
For more information, see Derating Parameters.
|