Parameter
|
Type
|
Description
|
---|---|---|
Quality Level
|
Choice List [Parts Count also]
|
The appropriate quality screening level of the device. Accepted quality levels and values for inductors follow.
• A2 = 0.30
• B1 = 0.70
• B2 = 1.00
• C = 4.00
|
Type
|
Choice List [Parts Count also]
|
The type of device. Choices vary by subcategory.
|
Construction Type
|
Choice List [Parts Count also]
|
Required only for the Coil subcategory.
The type of coil construction. Choices are:
• Fixed
• Variable
|
Rated Temperature
|
Choice List
|
The rated operation temperature of the device. Many different choices are available, including 90, 105, and more.
|
Temp Rise to Hot Spot
|
Real (Degrees C)
|
The temperature rise from the subassembly to the hot spot temperature.
|
Hot Spot Temperature
|
Real (Degrees C)
|
Generally, this field is left at #.# so that the hot spot temperature is calculated as follows:
Hot Spot Temperature = Subassembly Temperature + Temperature Rise to Hot Spot
If you enter a value for this parameter, this value is used in place of a calculated hot spot temperature.
|
[Derating Parameters]
|
---
|
For more information, see Derating Parameters.
|