Parameter
|
Type
|
Description
|
||
---|---|---|---|---|
Quality Level
|
Choice List [Parts Count also]
|
The appropriate quality screening level of the device. Accepted quality levels and values for capacitors follow. For the quality value assigned to a specific capacitor, see Chinese Standard GJB/z 299B.
• A1L = 0.03
• A1W = 0.10
• A = 0.30
• A2 = 0.30
• B1 = 0.50
• B2 = 1.00
• C = 5.00
• C1 = 3.00
• C2 = 5.00
|
||
Plastic Type
|
Choice List
|
Required only for the Plastic (CFR) subcategory.
The type of plastic from which the device is made. Choices are:
• Polypropolene, PTFE
• Terylene, Polystyrene
|
||
Capacitance
|
Real
|
The capacitance value of the device. This parameter is used in conjunction with Units to enter the capacitance value.
|
||
Units
|
Choice List
|
The units for the Capacitance value. Choices are:
• F (Farad)
• uF (micro Farad = F/1E6)
• nF (nano Farad = F/1E9)
• pF (pico Farad = F/1E12)
|
||
Class Level
|
Choice List [Parts Count also]
|
Required only for the following subcategories: Chip, Ceramic (CDR); General Ceramic (CK, CKR); and Temp Compensat, Ceramic (CC, CCR).
The class of the device. Choices are:
• 1
• 2
|
||
Rated Temperature
|
Choice List
|
Required only for the following subcategories: Button Mica (CB); Feed Through, Paper (CZ, CZR); Paper (CA, CP); Paper-Plastic (CQ, CQR, CPV); Metallized Paper-Plastic (CH, CHR); Plastic (CFR); Mica (CM, CMR); and Super Metallized Plastic (CRH). Also required for the following subcategories when the class level is 2: Chip, Ceramic (CDR); General Ceramic (CK, CKR); and Temp Compensat, Ceramic (CC, CCR).
The rated temperature of the device in degrees C.
|
||
Series Resistance
|
Real
|
Required only for the following subcategories: Chip, Elec (CWR) and Solid, Elec, Tant (CSR).
The circuit resistance of the device.
|
||
[Voltage Parameters]
|
Real (Watts)
|
For more information, see Voltage Parameters.
|
||
[Temperature Parameters)
|
Real (Degrees C)
|
For more information, see Basic Temperature Parameters.
|
||
[Derating Parameters]
|
---
|