Object
|
Description
|
Type
|
Displays the type of S1000D product.
|
S1000D Help
|
Displays this help topic when clicked.
|
Object
|
Description
|
Name
|
Specify the name of the product.
|
Description
|
Add a free text description of the product.
|
Owner
|
Displays the owner of the product.
|
Private Access
|
If Yes, then access is restricted to use only the access control policies that are defined within the product context being created. The product does not inherit any public access policy rules written at the organization level.
If No, then the product is accessible based on the following:
• the access control policies that are defined for the product context.
• those inherited access control policies defined in the parent context.
See your administrator for more information on access control.
|
Object
|
Description
|
Security Classification
|
Specify the default security classification for the project.
|
Item Location Code
|
Set the project default Item Location Code:
• A — On End Item
• B — On Major Assembly
• C — On Removed Equipment
• D — Any of A, B, or C.
• T— Training only
• Z— Generic item location code
|
Responsible Partner Company
|
Set the default Responsible Partner Company NSCM code and name.
|
Originator
|
Set the default NSCM code and name.
|
Language Code
|
Set the default language code.
|
Country Code
|
Set the default country code.
|
Object
|
Description
|
RPC — Use Enterprise Name
|
If set to Yes, the RPC name (<responsiblePartnerCompany><enterpriseName>) is included in the ID and Status sections of the project’s data modules.
|
RPC — Use Enterprise Code
|
If set to Yes, the originator code (<responsiblePartnerCompany> attribute enterpriseCode) is included in the ID and Status sections of the project’s data modules.
|
Originator — Use Enterprise Name
|
If set to Yes, the originator name (<originator><enterpriseName>) is included in the ID and Status sections of the project’s data modules.
|
Originator — Use Enterprise Code
|
If set to Yes, the RPC code (<originator> attribute enterpriseCode) is included in the ID and Status sections of the project’s data modules.
|
Include Info Name in DM
|
If set to Yes, the information name (<dmTitle> <infoName>) is used in the ID and Status sections of the project’s data modules.
|
Include DM Title in Referenced DMs
|
If set to Yes, the data module title (<dmTitle>) is populated in the ID and Status sections for referenced data modules.
|
Object
|
Description
|
Use Model ID-based ICNs
|
Set to Yes if you want to use Model Identification Code-based Information Control Numbers.
|
Responsible Partner Company Code
|
Enter the RPC code that is used during subsequent ICN creation.
|
Originator
|
Select the originator from the pull-down list.
|
Issue Number Length
|
Define the length of the Issue Number on newly created ICNs.
Different issues of the S1000D specification require different padding lengths for Issue Number.
|
Unique Identifier — Allow Gaps in Sequence
|
Specify whether gaps in the numbering sequence are filled or not.
For example, if you have an ICN with sequence number 00002, and the sequence is starting from 0:
• If this is set to No, a new ICN is given the sequence number 00001, and the next is given 00003
• If it is set to Yes, the first ICN is given the sequence number 00003, and the next is given 00004.
|
Security Classification
|
Specify the default security classification for the project.
|
Object
|
Description
|
Use CAGE Code-based ICNs
|
Set to Yes If you want to use CAGE Code-based Information Control Numbers.
|
CAGE Code
|
Select the originator from the pull-down list.
|
Unique Identifier Prefix
|
Enter the unique identifier that is used during subsequent ICN creation.
|
Unique Identifier Length (including prefix)
|
Specify the length of the Unique Identifier on newly created ICNs.
Different issues of the S1000D specification require different padding lengths for Unique Identifier.
|
Unique Identifier — Allow Gaps in Sequence
|
Specify whether gaps in the numbering sequence are filled or not.
For example, if you have an ICN with sequence number 00002, and the sequence is starting from 0.
• If this is set to Yes, a new ICN is given the sequence number 00001, and the next is given 00003
• If it is set to No, the first ICN is given the sequence number 00003, and the next is given 00004.
|
Security Classification
|
Specify the default security classification for the project.
|
Object
|
Description
|
||
Use ICN Metadata Files
|
Set to Yes if you want the product to support ICN Metadata Files (IMF).
|
||
Populate figure/multimedia title from ICN Metadata
|
Set to Yes if you want the title of figure/multimedia parent objects for ICNs in the product to be automatically set to the ICN Title of the ICN’s associated IMF (icnTitle element).
If Yes, the title of the figure/multimedia object is set when an ICN with a linked IMF is inserted in Arbortext Editor.
|
Object
|
Description
|
Allow Check In With Invalid Schema
|
If Yes is selected, the data modules can still be checked in even if schema validation errors are found.
|
Allow Check In With Unparsed Entities
|
If Yes is selected, the data modules can still be checked in even if unparsed entity validation errors are found.
|
Object
|
Description
|
Allow Check In With Invalid Brex
|
If Yes is selected, the data modules can still be checked in even if BREX validation errors are found.
|
Object
|
Description
|
Host URL
|
Specifies the Servigistics InService A&D host for data upload.
This must be a valid Servigistics InService A&D host location.
|
DMS Output Path
|
Specifies the Servigistics InService A&D publishing folder.
This must resolve to the same path as the DMSOutputPath defined in Servigistics InService A&D.
Recommended formats are a UNC path (for example, \\server\share) or a mapped drive path (for example, x:\share).
|
Publication Identifiers
|
Specifies the list of Servigistics InService A&D publication identifiers that apply for the product.
Use the + option to enter multiple publication identifiers for the product if required. You can select from this list when creating a new publication structure, if you want to set a default identifier for the structure.
Each Publication Identifier can include alphanumeric characters including the standard dash character (-), and open ([) and close (]) square brackets.
|
Store Copy of Published Data
|
Specifies whether a copy of the published data is stored in Windchill.
Select Yes to store the published data in Windchill.
|
Object
|
Description
|
Reference Mechanism
|
Specifies the types of reference that can be used in a data module to access CIR/TIR data.
The section is named Technical Information Repository Reference Type if creating a product using S1000D Issue 4.0.1.
|
Object
|
Description
|
OK
|
Creates the new product and closes the dialog box.
|
Cancel
|
Cancels the current operation and closes the dialog box.
|