SysML, UAF, UML, and UPDM Profiles > SysML profile > Blocks > Ports, flow specifications and interface blocks > Full port > Creating a full port (SysML)
  
Creating a full port (SysML)
You can create typed and untyped Full Ports in the model. After creating a Full Port, you can set or change its type.
For information about creating a Full Port on an Internal Block Diagram, click here
To create a full port:
1. In an appropriate pane, right-click the Block or Interface Block that is to own the Full Port, point to New, point to SysML, and then click Full Port
2. To use an existing item as a type:
a. In the Options group, click the Existing Type option.
b. Select the item that you want to use as a type, and then click OK.
Note that, in the Existing Type: pane, you can click the Find Items button to open the Add New Search Folder dialog where you can specify the Type and a subset or the full Name of the items that you want to find.To create a new item to use as a type:
a. In the Options group, click the New Type option.
b. From the Type list, select the type of the item you want to create and use as a type.
c. In the Name box, type the name of the item that will be used as a type, and then click OK.
To create an untyped Full Port:
In the Options group, click the Untyped option, and then click OK
3. Type the name of the Full Port, and then press the Enter key.
After creating a Full Port, you can specify its multiplicity and specify whether the Full Port is read only. For more information see the Full Port topic in the Related Topics.