Column
|
Value
|
---|---|
#TOL or #TOL#<DAT VALUE>
|
The unit of the dowel pin, either MM or INCH. This is always the first column.
|
DN
|
The dowel pin diameter.
|
STRING
|
The string you can select from the Tolerance list in the Dowel Pin Fastener Definition dialog box. If an ISO tolerance field such as H7 is entered, then the fit is automatically assigned to the hole diameter. In this case no values for the columns LOWER and UPPER are required.
|
NOM
|
The nominal hole diameter.
|
LOWER
|
The lower limit dimension.
|
UPPER
|
The upper limit dimension.
|
|
Set the Creo Intelligent Fastener option PIN_DIAMETER_FOR_HOLECHART to DN or NOM to determine from what column in the ifx_pin_data.cfg file, you get the corresponding hole chart (*.hol).
|