Electrical Design > Cabling > Using Parameters in Cabling > To Specify a Single Value for Parameters Across Multiple Connectors
To Specify a Single Value for Parameters Across Multiple Connectors
1. Click Cabling Parameters. You can select a component in the Model Tree or graphics window, right-click, and choose Cabling Parameters. You are prompted to select a cabling component.
2. Select the connectors and click OK. The Electrical Parameters dialog box opens.
3. Under Display For, click Pins.
4. Expand Pins.
5. In the right panel of the dialog box, click multi select to the right of Pins and above the parameter you want to edit. A prompt appears above the tree headings. Values for most columns are As Is. This means that values differ for the same pin name across connectors.
6. Type a new value for the parameter in the Value box and press ENTER. The values for the selected parameter are updated across all listed connectors for the specified pin.
7. Click Apply and then OK.