Broadband Source Model Simulation Exercise 5— Assigning Boundary Conditions
Rotor Boundary Conditions
1. Under Boundary Conditions for > , select PROPELLER_Body_1.
2. In the Properties panel, click the Model tab.
3. For Flow, set the following values:
◦ Flow—Rotating Wall
◦ Rotational Direction—Counterclockwise
◦ Rotational Speed—5100 rpm
◦ Rotational Axis Vector—0,0,-1
◦ Rotor Center—0,0,0
Rotating Volume Conditions
1. Under Domains, select PROPELLER_Body_1.
2. In the Properties panel, click the Model tab.
3. For Flow, set the following values:
◦ Noninertial Frame—Noninertial Frame
◦ Rotational Direction—Counterclockwise
◦ Rotational Speed—5100 rpm
◦ Rotational Axis Vector—0,0,-1
◦ Rotor Center—0,0,0
Outlet Boundary Conditions
1. Under Boundary Conditions for General Boundaries, select outside_dir1_max, outside_dir1_min, outside_dir2_max, outside_dir2_min, outside_dir3_max and outside_dir3_min.
2. In the Properties panel, click the Model tab.
3. For Flow set the following values:
◦ Flow—Specified Pressure Outlet
◦ Pressure—0 Pa