Option
|
Description
|
---|---|
Verify
The checkboxes below this heading indicate the block properties to verify. By default, all checkboxes are selected.
|
|
Connections
|
When selected, a check is performed to see that all blocks and junctions have inputs and outputs, thereby incorporating them into the system analysis.
|
Component identifiers
|
When selected, a check is performed to see that all component identifiers assigned to blocks and junctions are unique.
|
Failure distribution
|
When selected, a check is performed to see that the value provided for the selected failure distribution is appropriate.
|
Load sharing
|
When selected, checks are performed for load-sharing junctions to ensure that the following conditions are met:
• Neither a junction nor a repeated block can be an input to a load-sharing junction.
• A block that is an input to a load-sharing junction can have only one input and one output.
• Each input into a load-sharing junction must have the same junction as its input.
|
Restoration distribution
|
When selected, a check is performed to see that the value provided for the selected restoration distribution is appropriate.
|
Dependencies
|
When selected, checks are performed to see that the trigger source and maintenance to perform exist.
|
Diagram
The options below this heading indicate which diagrams to include in the verification process.
|
|
Verify current diagram
|
When selected (default), verifications are performed on only the currently selected diagram in the RBD Table.
|
Verify current diagram and all linked diagrams
|
When selected, verifications are performed on the currently selected diagram in the RBD Table and on any diagrams to which this diagram is linked.
|
Verify all diagrams
|
When selected, verifications are performed on all diagrams in the RBD Table.
|