Parameter
|
Type
|
Description
|
---|---|---|
Quality Level
|
Choice List [Parts Count also]
|
The quality screening level used in the manufacturing of the device. Choices vary by subcategory. For more information, see MIL-HBDK-217 Quality Levels.
|
Construction Type
|
Choice List
|
Not required for the following subcategories: Electronic Time Delay, Non-Thermal; Solid State, Time Delay; and Thermal, Bimetal.
The construction type of the device. Choices vary by subcategory.
|
Type
|
Choice List [Parts Count also]
|
Required only for the Solid State, Time Delay subcategory.
The type of solid state relay. Choices are:
• Solid State
• Time Delay
• Hybrid
|
Contact Form
|
Choice List
|
Not required for the Solid State, Time Delay subcategory.
The number and type of active conducting contacts. Many different choices are available, including SPDT, 3PST, and more.
|
Max Rated Temp
|
Choice List
|
Not required for the Solid State, Time Delay subcategory.
The maximum temperature rating for the device in Degrees C. Choices are:
• 85
• 125
|
Load Type
|
Choice List
|
Not required for the Solid State, Time Delay subcategory.
The type of load connected external to the device. Choices are:
• Lamp
• Inductive
• Resistive
|
Cycling Rate (#/hour)
|
Real
|
Not required for the Solid State, Time Delay subcategory.
The average number of switching cycles per hour.
|
[Current Parameters]
|
Real (Amps)
|
Not required for the Solid State, Time Delay subcategory.
For more information, see Current Parameters.
|
[Temperature Parameters]
|
---
|
Not required for the Solid State, Time Delay subcategory.
For more information, see Basic Temperature Parameters.
|
[Derating Parameters]
|
---
|
For more information, see Derating Parameters.
|