Entering FIDES Resistors
The following table describes the part parameters required for resistors when a FIDES model is selected for the calculation. FIDES models support the following subcategories of resistors:
Cermet Adjustment Trimmer
High Stability Bulk Metal Foil Precision
Lower Power Film (Minimelf)
Lower Power Wirewound Precision
Power Film
Power Wirewound
Resistive Chip
SMD Resistive Grid
* 
The FIDES 2004 model does not support the High Stability Bulk Metal Foil Precision subcategory. Only FIDES 2009 models support this subcategory.
Parameter
Type
Description
[Standard FIDES Parameters]
---
For more information, see FIDES Standard Part Parameters.
Type
Choice List
Required only by the FIDES 2009 model for the High Stability Bulk Metal Foil Precision subcategory.
The method by which the device is mounted. Choices are:
SMD (for a surface-mounted device)
Through Hole
Resistance
Real
Required only by the FIDES 2009 model for the High Stability Bulk Metal Foil Precision subcategory.
The resistance value of the device. This parameter is used in conjunction with Units to enter the resistance units.
Units
Choice List
Required only by the FIDES 2009 model for the High Stability Bulk Metal Foil Precision subcategory.
The units for the Resistance value. Choices are:
ohm
Kohm (ohm * 1000)
Mohm (ohm * 1E6)
Dissipation
Choice List (Parts Count only)
Required only by the FIDES 2009 Parts Count model for the following subcategories: Lower Power Film (Minimelf), Low Power Wirewound Precision, Power Film, and Power Wirewound.
Indicates whether the device is high or low in power dissipation.
Resistor Network
Checkbox
For the FIDES 2004 model only, required for all but the SMD Resistive Grid subcategory.
Indicates whether the device is a series of resistors connected in series or parallel.
Resistor Quantity
Integer
For the SMD Resistive Grid subcategory, this parameter is always available. For the FIDES 2004 model only, for other subcategories, it is available only when Resistor Network is selected.
The number of resistors in the network or grid. Do not include resistors that are not used.
[Power Parameters]
Real
For more information, see Power Parameters.
[Derating Parameters]
---
For more information, see Derating Parameters.