Entering 217Plus Relays
The following table describes the part parameters required for relays when 217Plus is the selected calculation model. This model supports the following subcategories of relays:
Electronic Time Delay, Non-Thermal
General Purpose
Reed, Dual In Line
Solid State, Time Delay
Thermal, Bimetal
Parameter
Type
Description
Year of Manufacture
Integer
The four-digit year in which the device was manufactured (such as 1998 or 2004). The default is the current year.
[Temperature Parameters]
---
The 217Plus model for relays does not provide for temperature changes. To meet customer demands for a way to make temperature adjustments, Temperature Rise and Case Temp Override are provided. For more information, see Basic Temperature Parameters.
[Derating Parameters]
---
For more information, see Derating Parameters.