Hybrid Data for MIL-HDBK-217 Models
When Hybrid is selected in the General Data pane for an assembly, the following form is shown in the Hybrid pane if a MIL-HDBK-217 model is selected.
Hybrid Data for MIL-HDBK-217 Models
The following table describes the data fields that appear in the Hybrid pane for a MIL-HDBK-217 model.
Field
Description
Hybrid circuit type
The type of circuit for the hybrid. Choices are:
Digital
Linear
Microwave
Power
Video
Hybrid quality
The quality screening level used in the manufacturing of the hybrid. Choices are B, B-1, Commercial and S. If the hybrid is screened to a custom or intermediate program, you can enter a Pi Q value for Hybrid Pi Q. For more information, see MIL-HBDK-217 Quality Levels.
Hybrid years in production
The number of years the hybrid has been in production. Choices are:
<=0.1
=2.0.
0.5
1.0
1.5
Hybrid max temperature
The maximum case temperature of the hybrid in degrees C. The default is 150.00.
Hybrid Pi Q
The Pi factor value to use in the model’s failure rate calculation for the hybrid if it is screened to a custom or intermediate program.