Entering FIDES Inductors and Transformers
The following table describes the part parameters required for inductors and transformers when a FIDES model is selected for the calculation. For the Inductor, Transformer category, FIDES models support two subcategories:
Inductor
Transformer
Parameter
Type
Description
[Standard FIDES Parameters]
---
For more information, see FIDES Standard Part Parameters.
Type
Choice List [Parts Count only for Transformer category]
The type of inductor or transformer, depending on the subcategory selected. Choices vary by subcategory.
Temperature Rise
Real (Degrees C)
The rise in temperature between the operating temperature and the case. If you enter a value for this parameter, this value is added to the operating temperature.
[Derating Parameters]
---
For more information, see Derating Parameters.