Entering 299B Alphanumeric Display Devices
The following table describes the part parameters required for Alphanumeric Display devices when 299B is the selected calculation model.
Parameter
Type
Description
Quality Level
Choice List [Parts Count also]
The appropriate quality screening level of the device. Accepted quality levels and values for this subcategory follow.
A2 = 0.08
A3 = 0.15
A4 = 0.30
B1 = 0.60
B2 = 1.00
C = 5.00
# of Characters
Integer [Parts Count also]
Required for the Alphanumeric Display subcategory.
The number of characters in the display.
[Temperature Parameters
---
For more information, see Comprehensive Temperature Parameters.
[Derating Parameters]
---