General Project Properties
The following table describes the properties that appear under General in the Project properties.
Property
Description
Description
A description of the Project.
Enable Alerts (Enterprise Edition only)
Indicates whether to enable the Project’s Alert file so that alerts are sent. When this checkbox is cleared (default), the Alert file is not enabled. When it is selected, the Alert file is enabled. In this case, the Windchill Risk and Reliability Alert Service checks the Project once every minute and sends out necessary alerts. For more information, see Alerts (Enterprise Edition Only).
* 
When a Project created in a version that used the Alert Setup utility is converted to Windchill Risk and Reliability, 10.2 or later, this checkbox is selected if its Alert file is selected in that utility.
Enable Audit Trail (Enterprise Edition only)
Indicates whether to enable the Audit Trail application so that modifications made to primary tables in System files for Enterprise Projects are tracked. For more information, see Audit Trails (Enterprise Edition Only). When this checkbox is cleared (default), Audit Trail files are not generated. When it is selected, Audit Trail files are generated.
Enable Master Filter file
Indicates whether to enable the Master Filter file so that all supplied filters are available for selection. For more information, see Filters. When this checkbox is selected (default), this Filter file is enabled.
Enable Master List Library file
Indicates whether to enable the Master List Library file so that all of supplied lists are available for selection. For more information, see List Library Files. When this checkbox is selected (default), this List Library file is enabled.
Part Number
The part number for the Project.
Prompt on Assembly Library inserts
Indicates whether to open a window in which you select the Assembly Library file into which to insert a System file assembly. When this checkbox is cleared (default), the System file assembly is inserted into the first Assembly Library file in the specified search order for which you have write permissions. When this checkbox is selected, a window opens for selecting the Assembly Library file into which to insert the System file assembly. All Assembly Library files for which you have write permissions are available for selection. For more information, see Assembly Library Files.
Read-Only
Indicates whether to treat all files in the Project as read-only. When this checkbox is cleared (default), files in the Project can be modified. When this checkbox is selected, files in the Project cannot be modified. While you can still use read-only Project files as the basis for reports or graphs and export the data in these files, you cannot create new files or rename or delete existing files.
Reference Designator
An identifier for systematically recognizing the Project.
Repair Time units
The units for calculating MTTR (mean time to repair) for the FRACAS and Prediction modules. The choices are Hours and Minutes. The default is Minutes.
Result units
The units for calculating result times for the FRACAS and Prediction modules. The choices are Hours and Minutes. The default is Hours.
Simplify file inputs
Indicates whether you can create multiple Table Format files per table type and multiple Form Set files. When this checkbox is selected (default), you can have only one Table Format file per table type and one Form Set file. When this checkbox is selected, you can have multiple Table Format files and Form Set files, which means you can configure multiple System file views. For more information, see Simplify File Inputs.