Number of Interconnections
The following points must be observed when counting the number of interconnections (NI) to be used in the model:
Each active (current-carrying) wire and each beam lead or solder blob should be counted as one interconnection.
Redundant interconnections should be counted as only one interconnection.
A bond should be considered bimetallic if any one of the bond interfaces involves more than one type of metal.
Active die attach bonds (die to substrate bonds) should not be counted as interconnections.
If an accurate count of interconnections cannot be obtained, the approximations in Table 3-3 may be made:
Table 3-3. Approximations for Number of Interconnections
Component
Number of Interconnections
Each IC chip bonding pad
1
Each transistor
2
Each diode
1
Each capacitor
2
Each external lead
1
Each chip resistor
2