Sync exception |
The sync exception indicator appears next to shared objects that are excluded from filter criteria. For example, if you are using a baseline configuration specification filter and share an object that is not included in the baseline. Sync exception objects are not eligible for the Update Project operation. You can remove the share, convert to a PDM checkout, or modify the filter criteria to include these objects. |
Out of sync share |
The out of sync indicator appears next to shared objects that are included in filter criteria but have been modified in the source context. For example, if you are using the default Latest configuration and modify a part, then the shared part is considered out of sync. Use the Update Project action to update out of sync objects. |
|
Sharing Filter Rules
|
All Filters
◦ Only shared filters appear in the Sharing Filter drop-down menu when creating and editing a project. You can share a filter using the Manage Filters action.
◦ The filter must be created from a part structure browser.
◦ If you do not specify a filter when creating or editing a project, the Latestconfiguration specification is used. This means that when the object is updated in PDM, it is considered out of sync and you should update the project. (This is the legacy behavior.)
Filters with Latest
By default, the filter is set to the basic Latest configuration specification. This simply means that whenever the object is updated in PDM, it is considered out of sync and you should update the project.
However, this behavior applies differently to objects that are recorded in the project baseline (such as parts and CAD documents) and to those that are not (such as documents). For a complete list of objects that are recorded in the project baseline, see Valid Object Types.
◦ Documents
▪ Shared documents are automatically updated when the source document is iterated. ▪ The out-of-sync status indicator does not appear for shared documents, even when revised. ▪ You cannot update a shared document to the latest revision. You must share the latest revision in a separate action. ◦ Parts, EPM documents (CAD and dynamic documents), and shared objects that are added to the project baseline ▪ The out-of-sync status indicator appears when the current version of the source object is iterated. ▪ The out-of-sync status indicator does not appear when the source object is revised. ▪ When the source object is revised and you update the project, only the latest revision is shared. You cannot update to a specific iteration within a non-latest revision. For example, you cannot update from A.3 to A.4 if B.1 exists. Filters without Latest You are not required to include the Latest configuration specification in your sharing filter criteria. However, you should keep the following factors in mind: ◦ If the filter does not include the Latest specification, then it is possible for an object to be modified in PDM but not appear as out of sync. ◦ The Update Project action only updates out-of-sync objects. This means that if the sharing filter does not include the Latest specification, then the update action might not return the most recent PDM version. ◦ To perform a Convert to PDM Checkout operation, an object must be the latest iteration. In this case, you must use the Update Selected Shares action and edit the filter criteria. |