When using the Open as Upstream option the selected part appears in the left-hand side of the dual structure pane, which is the upstream window. All equivalent downstream parts are displayed in the right-hand side of the dual structure pane. When using the Open as Downstream option the selected part appears in the right-hand side of the dual structure pane, which is the downstream window. All equivalent upstream parts are displayed in the left-hand side of the dual structure pane.
|
Dual Structure Pane Task Tool Bar
|
||||
Icon
|
Action
|
Description
|
||
Open Part
|
Opens the Search window where you can search for an existing part to open.
|
|||
Close active structure
|
Closes the active structure.
|
|||
Edit Filter
|
Opens the Edit Filter window allowing you to change the configuration specifications used in your display.
|
|||
Show Filter List
|
Displays a list of filters currently in use.
|
|||
Refresh
|
Updates the structure of the selected object according to the current configuration specification.
|
|||
Open In Explorer
|
Opens the selected BOM in a new explorer window. See Opening Objects in an Explorer.
|
|||
Select In Explorer
|
Use to select the selected object and its related objects in an open explorer or selection tab. See Selecting Objects in an Explorer.
|
|||
Send Root Node in Downstream Tree
Send Root Node in Upstream Tree
|
If an upstream assembly is selected, this option moves the assembly to the downstream view to be used as a downstream part. If a downstream view is selected, this option moves the assembly to the upstream view to be used as an upstream part.
|
|||
Assemble Under New Part
|
Creates a new downstream part and then creates new equivalent links to the copied upstream part. When selected the New Name, New Unit of Measure, and New Number (if the auto-numbering option is disabled) columns can be updated. If the copied part is an assembly of parts, no children are created.
|
|||
Paste As New Part
|
Creates a new downstream part and then creates new equivalent links to the copied upstream part. When selected the New Name, New Unit of Measure and New Number (if the auto-numbering option is disabled) columns can be updated. If the copied part is an assembly of parts, no children are created.
|
|||
Replace with New Downstream Part Number
|
Adds the copied part and its upstream structure, and creates new equivalence links between the downstream BOM and the upstream BOM.
|
|||
Update Positioning
|
If occurrence links exist, this option updates the structural position of a downstream part relative to its equivalent upstream part, if the upstream part has been moved to a new position in the assembly.
|
|||
Update Usage Options
|
Processes downstream usages for which at least one valid occurrence link can be found to an upstream BOM.
|
|||
Update Equivalent Part
|
Updates a part's equivalent link to the latest equivalent part's version. If the updated downstream part is an assembly, the positioning of the child parts is also updated.
|
|||
Remove Selected Assembly and Move Up Child Parts
|
Removes the selected assembly node and moves all children to the next available parent in the hierarchy.
|
Dual Structure Pane Middle Bar
|
||
Icon
|
Action
|
Description
|
Open Equivalent Part in other Tree
|
Displays the equivalent part of the selected part in the opposing structure pane.
|
|
Create Equivalence Link
|
Creates an equivalent link between the part selected in the upstream structure pane, and the part selected in the downstream structure pane.
|
|
Reconcile Selected Structures
|
Reconciles differences between source and service BOM parts.
|
|
Assemble As Selected Part
|
Adds the copied part and its upstream structure, and creates new equivalence links between the downstream BOM and the upstream BOM.
|
|
Assemble As New Part
|
Creates a new downstream part.
|
|
Select Equivalent Part in other Tree
|