Enterprise Administration > Windchill Export and Import > PTC Windchill PLM Connector - Creo Packages Administrator's and User's Guide > Windchill PLM Connector – Creo Packages > Importing Packages > Conflict Handling and Resolution > Conflict Resolution > Suggested Actions For Resolving Conflicts > Overridable
  
Overridable
The following actions are suggested for overridable conflicts:
Label in the report
Type of Conflict Message
Resolution
Error code: OVERRIDE_MISSING_REF
The following references are expected to exist in the target PLM system, but they are missing in target PLM system.
Object-level
IGNORE_MISSING_REF
Ignore if the expected object does not exist in the target PLM system.
REUSE_OR_IGNORE_MISSING_REF
If the name and master ID of the model file in the package and target database match, reuse the file in the target PLM system. Otherwise, ignore the file.
Error code:
OVERRIDE_LATER_VERSION
Later versions of the following objects already exist in the target PLM system.
Object-level
Creo Parametric may not be able to regenerate the object.
LASTEST_VERSION_REUSEUSE
Use the object from the target PLM system.
Error code:
OVERRIDE_FOLDER_NOT_FOUND
The specified folder not found in the target PLM system.
A mapped folder does not exist in the target PLM system.
Definition-level
CREATE_TARGET_FOLDER
In this example, the resolution works only if the inherited release level scheme agrees the mapping.
Error code:
REVISE_INPDMLINK
The incoming object has a different revision.
The package contains objects with a different revision, and objects have already been PDM checked in.
Definition-level
REVISE_INPDMLINK
For example:
Conflict.OVERRIDE_NEW_REVISION=REVISE_IN_PDMLINK