Enterprise Administration > Windchill Export and Import > PTC Windchill PLM Connector - Creo Packages Administrator's and User's Guide > Windchill PLM Connector – Creo Packages > Importing Packages > Conflict Handling and Resolution > Conflict Resolution > Suggested Actions For Resolving Conflicts > Non-overridable
  
Non-overridable
The following actions are suggested for non-overridable conflicts:
Label in the report
Type of Conflict Message
Suggested Action
The following objects with the same file name already exist in target.
Object-level
Ignore the complete package.
Rename the object either in the source PLM system or the target PLM system, depending on which PLM system owns the object.
Cannot rename bolt.prt to bolt1.prt as object with the same name exists.
Object-level
Ignore the complete package.
Rename the object either in the source PLM system or the target PLM system, depending on which PLM system owns the object.
You do not have authorization to modify the following objects.
Definition-level
While exporting do not include these objects in the package. While importing do not import this package.
The following objects are expected to exist in the target PLM system, but they do not exist in the target PLM system.
Object-level
Expected files available in the target PLM system with same Object ID.
The lifecycle state/ release level of the following objects could not be updated.
Object-level
Manually change the life cycle state of this object in the target PLM system to see the reason for the conflict and its resolution.
File Name could not be updated for the following objects.
Object-level
Rename this object in the target PLM system to see the reason for the conflict and its resolution.
The following missing dependents could not be resolved.
Object-level
You must create these objects in the target PLM system.
The following objects were saved using later version of Creo.
Object-level
Use a later version of Creo Parametric to perform the import.
The following folders could not be created.
Mapping file provides an invalid folder name.
You have no authorization to create a particular folder.
Definition-level
Create the folder manually in the target PLM system to see the reason for the conflict and its resolution.
Review the folder mapping.
The following target locations have incompatible release scheme/lifecycle.
Definition-level
Change the mapping to map to a valid release level or life cycle state.
Create a valid definition for the release scheme or release state in the target PLM system.
The following target locations have incompatible release level/lifecycle state mapping.
Definition-level
Change the mapping to a valid one.
Create a valid definition in the target PLM system.
The following revisions do not exist in the target PLM system.
Definition-level
Create a corresponding revision in the target PLM system, if it is allowed in your PLM system.
Map the missing revision to an existing revision in the target PLM system.
The following revisions have been mapped from multiple source revisions.
Multiple revisions from a single revision scheme in the source PLM system are mapped to a single revision in the target PLM system.
Definition-level
Map a single version from a revision scheme to only one revision in the target PLM system.