1. The preference View To Distribution Target Mappings takes a value of the form <View1>:<Number1>,<View2>:<Number2>,...<View n><Number n> where View1, View2, etc. are names of Windchill views and Number1, Number2, etc. are values of the number attribute of distribution targets. For example, the value can be Design:001,Manufacturing:002,Plant1:003. With such a setting in place, a distribution target with number 001 will be automatically assigned to a part created in the Design view, provided the target resides in the same context as the part and has its defaultForContext attribute set to true. See section Distribution Target Assignment Validation for more information on when a target will be considered a candidate for auto-assignment.
2. The automatic assignment of distribution targets happens at the time of publishing the part (this is true for other object types as well).
|