Creating a constraint parameter (SysML)
For information about creating a Constraint Parameter on a Parametric Diagram, click here
.
To create a constraint parameter:
1. Right-click the Constraint Block that is to own the Constraint Parameter, and select New > SysML > Constraint Parameter.
2. To use an existing Value Type as a type:
a. In the Options group, click the Existing Type option.
b. Select the Value Type that you want to use as a type, and then click OK.
Note that, in the Existing Type: pane, you can click the Find Items button to open the Add New Search Folder dialog where you can specify the Type and a subset or the full Name of the items that you want to find.
To create a new Value Type to use as a type:
a. In the Options group, click the New Type option.
b. From the Type list, select the type of the Value Type you want to create and use as a type.
c. In the Name box, type the name of the Value Type that will be used as a type, and then click OK.
To create an untyped Constraint Parameter:
In the Options group, click the Untyped option, and then click OK.
At some future time, you must create a type for the Constraint Parameter.
After creating a Constraint Parameter, you can specify a default value and its multiplicity, and set it up as read only and shared. For more information, see the Related Topics.