SysML, UAF, UML, and UPDM Profiles > SysML profile > Constraint blocks > Parametric diagrams for constraint blocks > Adding items and links to > Populating missing binding connectors on a parametric diagram (SysML)
  
Populating missing binding connectors on a parametric diagram (SysML)
You can populate Binding Connectors that are missing between symbols shown on the diagram, or populate all those Binding Connectors that are linked to a Constraint Parameter or Block Property on a diagram.
To populate all missing links:
Right-click the diagram background, point to Links, and then click All.
To populate missing binding connectors:
Right-click the background of the Parametric Diagram, point to Populate, point to Links, and then click Binding Connectors.
Modeler adds Binding Connectors that are missing between the items shown on the diagram.
To populate a constraint parameter's missing binding connectors:
Right-click the Constraint Parameter, point to Populate, point to Links, and then click Binding Connectors.
Modeler adds the Constraint Parameter's missing Binding Connectors - if Modeler needs to add missing items to show Constraint Parameter's missing Binding Connectors, those items are added to the diagram.
To populate a block property's missing binding connectors (connectors (block owned parametric diagrams only):
Right-click the Block Property, point to Populate, point to Links, and then click Binding Connectors.
Modeler adds the Block Property's missing Binding Connectors - if Modeler needs to add missing items to show Block Property's missing Binding Connectors, those items are added to the diagram.