Updating OSLC links for other providers
This topic discusses how to use the OSLC Links Editor tool to update OSLC links that have been created with other OSLC providers, such as, Windchill, Codebeamer, Polarion, and PTC RV&S.
To update OSLC links
1. Open the model that contains the OSLC links that require updating.
2. Open the OSLC links editor tool. On the Modeler ribbon toolbar, click > . The OSLC Links Editor dialog opens.
3. Click the Load OSLC Links from Active Model button. The OSLC Links by Server section is populated with a list of servers by name that have OSLC links in the selected model (not all mapped servers). Any servers listed in red are shown as a URL indicating that the server is not mapped (most likely the mapping for this server has been deleted). The number of OSLC links is shown by each server.
4. Select and expand the server that contains the OSLC links you want to update.
5. To update the server, select the server and on the right pane, click the refresh button next to the New list to view all available servers.
To update the ID, enter valid ID of the item and click Rebuild OSLC Link URIs. The updated OSLC link URIs are then listed in the Updated OSLC Links section. Note that in this table, you cannot test the updated links.
6. Click the Update Modeler button.
The links are now updated in Modeler.