DA_PP_DISPLAY terminate action

DA_PP_DISPLAY selects a standard view and adjusts the results window display to produce the desired view.

Syntax


-->(DA_PP_DISPLAY)-----+-----(:DA_VIEW_FIT)------------------------------+-->
                       |                                                 |
                       +-----(:DA_DYNAMICS_ZOOM)-------------------------+
                       |                                                 |
                       +-----(:DA_DYNAMICS_ROTATE)-----------------------+
                       |                                                 |
                       +-----(:DA_DYNAMICS_ROTATEZ)----------------------+
                       |                                                 |
                       +-----(:DA_DYNAMICS_MOVE)-------------------------+
                       |                                                 |
                       +-----(:DA_VIEW)-------------+--(:FRONT)------+---+
                       |                            |                |   |
                       |                            +--(:BACK)-------+   |
                       |                            |                |   |
                       |                            +--(:LEFT)-------+   |
                       |                            |                |   |
                       |                            +--(:RIGHT)------+   |
                       |                            |                |   |
                       |                            +--(:TOP)--------+   |
                       |                            |                |   |
                       |                            +--(:BOTTOM)-----+   |
                       |                            |                |   |
                       |                            +--(:ISOMETRIC)--+   |
                       |                            |                |   |
                       |                            +--(:DIMETRIC)---+   |
                       |                            |                |   |
                       |                            +--(:TRIMETRIC)--+   |
                       |                                                 |
                       +-------<-----------<----------<---------<--------+

Options

The following options are available to select a standard view and configure the results display.

When to use

Use this action when analyzing parts with Design Integrity.

Example

See also

DA_ANALYSE terminate action, DA_PP_ANIMATE terminate action, DA_PP_RESULTS terminate action