DA_ANALYSE configures and performs a finite element analysis of a part.
*3* - available only if the value of:MODEL
is:MODAL
or:LINEAR_BUCKLING
. *4* - available only if the value of:MODEL
is:MODAL
*5* - available only if the value of:MODEL
is:LINEAR_BUCKLING
-->DA_ANALYSE---+ | +---------------+ | +---+--+--(:STUDY)-----------------|SELECT S_FERRUM_STUDY|----------------+--> | | | | +--(:DA_MODEL)--------------+--(:LINEAR_STATIC)---(1)-+------------+ | | | | | | | +--(:P_LINEAR_STATIC)-(2)-+ | | | | | | | | +--(:MODAL)-----------(3)-+ | | | | | | | | +--(:P_MODAL)---------(4)-+ | | | | | | | | +--(:LINEAR_BUCKLING)-(5)-+ | | | | | | | | +--(:HEAT_TRANSFER)---(6)-+ | | | | | +--(:DA_MODE_CONTROL)-------+--(:LOWEST)-----------+--(3)-(4)-(5)--+ | | | | | | | +--(:LOWEST-IN-RANGE)--+ | | | | | | ^ | +--(:ALL-IN-RANGE)-----+ | | | | | | | | +--(:LOWEST-ABOVE)-----+ | | | | | +--(:DA_ERROR_PERCENTAGE)---------|positive-number|---(2)-(4)------+ | | | | +--(:DA_MIN_ORDER)----------------|positive-integer|--(2)-(4)------+ | | | | +--(:DA_MAX_ORDER)----------------|positive-integer|--(2)-(4)------+ | | | | +--(:DA_MAX_ITERATIONS)-----------|positive-integer|--(2)-(4)------+ | | | | +--(:DA_NUM_MODES)----------------|number|------------(3)-(4)-(5)--+ | | | | +--(:DA_LOWER_CUTOFF_FREQ)--------|frequency|---------(3)-(4)------+ | | | | +--(:DA_UPPER_CUTOFF_FREQ)--------|frequency|---------(3)-(4)------+ | | | ^ +--(:DA_LOWER_CUTOFF_EIGENVALUE)--|number|------------(5)----------+ | | | | +--(:DA_UPPER_CUTOFF_EIGENVALUE)--|number|------------(5)----------+ | | | | +--(:DA_STRESS_TOGGLE)-----------+--(:ON)---+----------------------+ | | | | | | | +--(:OFF)--+ | | | | | +--(:DA_DISPLACEMENT_TOGGLE)-----+--(:ON)---+----------------------+ | | | | | | | +--(:OFF)--+ | | | | | +--(:DA_STRAIN_TOGGLE)-----------+--(:ON)---+----------------------+ | | | | | | | +--(:OFF)--+ | | | | | +--(:DA_REACTION_FORCE_TOGGLE)---+--(:ON)---+----------------------+ | | | | | | | +--(:OFF)--+ | | | | | +--(:DA_APPLIED_LOADS_TOGGLE)----+--(:ON)---+----------------------+ | | | | | ^ | +--(:OFF)--+ | | | | | +--(:DA_ELEMENT_FORCE_TOGGLE)----+--(:ON)---+----------------------+ | | | | | | | +--(:OFF)--+ | | | | | +--(:DA_STRAIN_ENERGY_TOGGLE)----+--(:ON)---+----------------------+ | | | | | | | +--(:OFF)--+ | | | | | +--(:DA_TEMPERATURE)-------------+--(:ON)---+----------------------+ ^ | | | | | | +--(:OFF)--+ | | | | | +--(:DA_FLUX)--------------------+--(:ON)---+----------------------+ | | | | | +--(:OFF)--+ | | | +-------<-----------<----------<---------<-----------<---------<------+
:STUDY
- specifies the study to associate with the analysis.
:DA_MODEL
- enables selection of the analysis type.
:LINEAR_STATIC
- selects Linear Static Analysis.
:P_LINEAR_STATIC
- selects P-Linear Analysis.
:MODAL
- selects Modal Analysis.
:P_MODAL
- selects P-Modal Analysis.
:LINEAR_BUCKLING
- selects Linear Buckling Analysis.
:HEAT_TRANSFER
- selects Steady-State Thermal Integrity Analysis.
:DA_MODE_CONTROL
- enables selection of the range of mode shapes to be analyzed in Modal or Linear Buckling Analysis.
:LOWEST
- selects a specified number of the lowest frequency or eigenvalue mode shapes (value from :DA_NUMBER_MODES
).
:LOWEST_IN_RANGE
- selects a specified number of the lowest frequency mode shapes in a specified frequency or eigenvalue range (values specified with :DA_NUMBER_MODES
, :DA_LOWER_CUTOFF_FREQ
, and :DA_UPPER_CUTOFF_FREQ)
.
:ALL_IN_RANGE
- selects all mode shapes in the specified frequency or eigenvalue range (values specified with :DA_LOWER_CUTOFF_FREQ
and :DA_UPPER_CUTOFF_FREQ
).
:LOWEST_ABOVE
- selects a specified number of mode shapes above a specified frequency or eigenvalue (values specified with :DA_NUMBER_MODES
and :DA_LOWER_CUTOFF_FREQ
).
:DA_ERROR_PERCENTAGE
- specifies the error tolerance as a percentage.
:DA_MIN_ORDER
- specifies the minimum element order.
:DA_MAX_ORDER
- specifies the maximum element order.
:DA_MAX_ITERATIONS
- selects the number of iterations.
:DA_NUMBER_MODES
- selects a specified number of mode shapes to be analyzed in Modal or Linear Buckling Analysis.
:DA_LOWER_CUTOFF_FREQ
- specifies the lower frequency limit for Modal Analysis.
:DA_UPPER_CUTOFF_FREQ
- specifies the upper frequency limit for Modal Analysis.
:DA_LOWER_CUTOFF_EIGENVALUE
- specifies the lower eigenvalue limit for Linear Buckling Analysis.
:DA_UPPER_CUTOFF_EIGENVALUE
- specifies the upper eigenvalue limit for Linear Buckling Analysis.
:DA_STRESS_TOGGLE
- selects stress as a desired result information.
:DA_DISPLACEMENT_TOGGLE
- selects displacement as a desired result information.
:DA_STRAIN_TOGGLE
- selects strain as a desired result information.
:DA_REACTION_FORCE_TOGGLE
- selects reaction forces as desired result information.
:DA_APPLIED_LOADS_TOGGLE
- selects applied forces as desired result information.
:DA_ELEMENT_FORCE_TOGGLE
- selects element forces as desired result information.
:DA_STRAIN_ENERGY_TOGGLE
- selects strain energy as desired result information.
:DA_TEMPERATURE
- selects temperature as desired result information.
:DA_FLUX
- selects heat flux as desired result information.