DA_CHECK_LENGTH calculates length information for part geometry.
Note: DA_CHECK_LENGTH will be implemented inside the standard OneSpace Designer environment.
-->(DA_CHECK_LENGTH)------+ | +-------------------------+ | +-------+-----(:LENGTH_MAX)---+---|length|---+---+ | | | | | +---(:ON)------+ | | | | | | +---(:OFF)-----+ | | | +-----(:LENGTH_MIN)---+---|length|---+---+ | | | | | +---(:ON)------+ | | | | | | +---(:OFF)-----+ | | | +-----(:SM_PART)----------|part|---------+ | | +-----(:DOIT)----------------------------+ | | +-------<-----------<----------<---------+
:LENGTH_MAX
- Specifies a maximum length. When :ON
is specified, all lengths in the part which are smaller than this value will be highlighted. If :OFF
is specified, the result is the maximum length of all faces.
:LENGTH_MIN
- Specifies a minimum length. When :ON
is specified, all lengths in the part which are greater than this value will be highlighted. If :OFF
is specified, the result is the minimum length of all faces.
:SM_PART
- specifies the part for the geometry length calculations.
:DOIT
- verifys values entered and activates the command.