Multiphase Flow for a Fuel Tank: Exercise 8—Analyzing Results
This exercise describes how you analyze the results during and after the simulation. To hide CAD surfaces (not the fluid domain), switch between Flow Analysis Bodies and CAD Bodies in the Show group. Clear any variable display by selecting No Selection in the Legend drop-down. Click XYPlot Panel to view the XY Plot.
* 
1. To show/hide selected geometric entities, click Show in View Panel.
2. To change the color scheme, click on More in the Legend and select between Blue Red and Blue Purple.
Plotting the Volume Fraction of Fuel in Tank
1. Under Domains select TANK.
2. Click XYPlot. A new entity xyplot1 is added in the Flow Analysis Tree under Results > XY Plots.
3. Select xyplot1.
4. In the Properties panel, Model tab, set the Variable to Volume Fraction:fuel:[Component]. The plot, as shown above, displays the volume fraction of the fuel filling the tank.
Plotting the Volume Fraction at a Section
Volume Fraction
fuel [-]
1. In the Flow Analysis Tree, under Results click Derived Surfaces.
2. Select Section 01.
3. In the Properties panel, Model tab, set values for the options as listed below:
TypePlane Y
Position— –2.615(minus 2.615)
4. In the Properties panel, View tab, for Surface set values for the options as listed below:
GridNo
OutlineYes
VariableVolume Fraction: fuel [-]: Component
Viewing an Isosurface of Points with Volume fraction of Fuel above 0.5
1. In the Post-processing group click Isosurface. A new entity Isosurface 01 appears under Derived Surfaces in the Flow Analysis Tree.
2. Select Section 01.
3. In the Properties panel, View tab, set values for the options as listed below:
GridNo
OutlineNo
4. Select Isosurface 01.
5. In the Properties panel, Model tab, set values for the options as listed below:
Isosurface VariableVolume Fraction: fuel [-]: Component
TypeAbove Value
Value—0.5
6. In the Properties panel, View tab, for Surface set a color of your choice and set Outline to No.