To Define a Temperature Measure
This procedure assumes you selected the Temperature quantity on the Measure Definition dialog box.
2. With the arrow button, select a point or appropriate reference entities as required by your selection for spatial evaluation.
3. If you want to define a transient thermal analysis, select the
Time Eval check box and specify a
time evaluation method.
4. If you want to know the time at which a minimum, maximum, or maximum absolute condition occurs, select the
Time Stamp checkbox.
5. Review the list box at the bottom of the dialog box to determine which type of analysis is valid for the measure.
6. Click OK. Each custom measure shows up on the Measures dialog box.