Parameter
|
Type
|
Description
|
---|---|---|
Quality Level
|
Choice List
|
The quality screening level used in the manufacturing of the device. For more information, see Telcordia Quality Levels.
|
Type
|
Choice List
|
The type of device. Choices vary by subcategory.
|
Temp Rise to Hot Spot
|
Real (Degrees C)
|
Not required if Method I Case 1 or Method I Case 2 is selected as the calculation method.
For other calculation methods, The temperature rise from the subassembly to the hot spot temperature.
|
Hot Spot Temperature
|
Real (Degrees C)
|
Not required if Method I Case 1 or Method I Case 2 is selected as the calculation method.
For other calculation methods, this field is generally left at #.#. so that the hot spot temperature is calculated as follows.
Hot Spot Temperature = Subassembly Temperature + Temperature Rise to Hot Spot
If you enter a value for this parameter, this value is used in place of a calculated hot spot temperature.
|
[Derating Parameters]
|
---
|
For more information, see Derating Parameters.
|