Entering Telcordia Inductors
The following table describes the part parameters required for inductors when a Telcordia model is selected for the calculation. These models support all but the Chip subcategory of inductors.
Parameter
Type
Description
Quality Level
Choice List
The quality screening level used in the manufacturing of the device. For more information, see Telcordia Quality Levels.
Type
Choice List
The type of device. Choices vary by subcategory.
Temp Rise to Hot Spot
Real (Degrees C)
Not required if Method I Case 1 or Method I Case 2 is selected as the calculation method.
For other calculation methods, The temperature rise from the subassembly to the hot spot temperature.
Hot Spot Temperature
Real (Degrees C)
Not required if Method I Case 1 or Method I Case 2 is selected as the calculation method.
For other calculation methods, this field is generally left at #.#. so that the hot spot temperature is calculated as follows.
Hot Spot Temperature = Subassembly Temperature + Temperature Rise to Hot Spot
If you enter a value for this parameter, this value is used in place of a calculated hot spot temperature.
[Derating Parameters]
---
For more information, see Derating Parameters.