Parameter
|
Description
|
||
---|---|---|---|
Quantity
|
The number of random points to generate for the data set. The default is 10. For a reliability growth data set with a data type of Duane Cumulative, this parameter is unavailable when Time is selected as the termination type.
|
||
(Slope) and (Scale) and possibly (Location)
|
The slope and scale parameters for the distribution and model selected in the Weibull Parameters pane. For example, if the distribution/model combination is Weibull/Three Parameters, then β, η, and γ values are entered for the slope, scale, and threshold parameters. For model/distribution combinations, see Models Per Distribution.
|
||
Percent Suspension
|
The percentage of suspensions. This parameter is available only if the distribution supports suspensions and Suspensions is selected in the Weibull Parameters pane. The default is 0.
|
||
|
|||
Interval Length
|
The length of the interval. This parameter is available only when Duane Interval or Crow/AMSAA Interval is selected as the data type in the Weibull Parameters pane. The default is 10.
|
||
Termination Type
|
Indicates whether the end of operation is due to a failure or reaching some specified amount of operating time. This parameter is available when Duane Cumulative or Crow/AMSAA Cumulative is chosen as the data type in the Weibull Parameters pane. Choices are:
• Failure. When selected (default), no other information is needed.
• Time. When selected, a termination time greater than or equal to the time of the last data point must be entered in the field to the right.
|