Parameter
|
Type
|
Description
|
---|---|---|
Type
|
Choice List
|
The type of tube. Many different choices are available. Parameter values are sometimes needed only for certain types. When this is the case, the types that require the parameter are noted.
|
Years in Production
|
Real
|
The numbers of years that the tube has been in production.
|
-TWT, Magnetron, Unlisted Klystron-
The parameters under this heading are required only for the following types: any Twystron or Magnetron type and unlisted Klystron types.
|
||
Power
|
Real
|
The value entered is based on the part type.
• For any Twystron type, the rated power of the tube in watts (W) for a non-Pulsed type or the peak rated power in megawatts (MW) for a Pulsed type.
• For any Magnetron type, the rated peak power of the tube in megawatts (MW).
• For any CW Klystron type, the average output power of the tube.
• For any Pulsed Klystron type, the peak output power of the tube in megawatts (MW).
|
Frequency
|
Real
|
The value entered is based on the part type.
• For any Twystron or Magnetron type and any Pulsed Klystron type, the operating frequency of the tube in gigahertz (GHz).
• For any CW Klystron type, the operating frequency of the tube. in megahertz (MHz).
|
-Magnetron-
The parameter under this heading is required only for the Magnetron types.
|
||
Radiate/Filament Hrs (%)
|
Real
|
The utilization frequency ratio of the magnetron. The equation is:
Radiate Hours / Filament Hours * 100
|
Rated Peak Power (MW)
|
Real
|
Required for Magnetrons only.
The rated peak power of the tube in megawatts.
|