Updating Fault Tree Events Globally
You can use the Global Change Wizard to update fault tree events globally.
1. In the FTA Table, select the top gate for the fault tree.
2. Select System > Global Change. The Global Change Wizard starts and displays the Select System Data page.
3. Select FTA events and click Next. The Select Fault Trees page appears.
4. Select the desired option.
Option
Description
All fault trees in my system
When selected (default), all trees in the system are updated.
Only the selected fault tree
When selected, only the selected tree is updated.
Selected fault tree and all children
When selected, the selected tree and all trees linked by transfer gates are updated.
5. Click Next. The Select Events page appears.
6. Select the desired option.
Option
Description
All events
When selected (default), all events are updated.
Events matching this filter
When selected, a field becomes available to the right for selecting the filter to use to limit the events you want to update. All fault tree filters in enabled Filter files are available for selection.
7. Click Next. The Change User Numeric, Change User Text, and Change Input Type pages are the next three page to appear. While the name of the field is different on each of these pages, the options are the same.
The following table describes the options on the Change User Numeric, Change User Text, and Change Input Type pages. The [X] represents the field name, which is a user numeric value, user text string, or input type.
Option
Description
Do not change the [X]
When selected (default), the value in the field is not changed.
Set the [X] to
When selected, in the field to the right, enter or select the new value for the field.
8. On the Change User Numeric, Change User Text, and Change Input Type pages, select the appropriate option and click Next.
If the input type is not being changed, the Confirm Changes page appears. Go to step 10.
If the input type is being changed, the Set Input Data page appears. The options on this page depend on the input type selected on the Change Input Type page. For descriptions, see Event Calculation Properties.
9. If the Set Input Data page appears, do the following:
a. Specify the input data values to use.
b. Click Next. The Confirm Changes page appears.
Because global changes cannot be undone, No is the default option. You must select Yes to make the Next button available.
To cancel the Global Change Wizard and discard your changes, you would click Cancel. When the confirmation window opens, you would click Yes to confirm these actions or No to return to the Confirm Changes page in the wizard.
10. On the Confirm Changes page, click Yes and then click Next. The final page of the Global Change Wizard appears, indicating that these changes cannot be undone.
If you click Back instead of Finish, the default selection of No is restored on the Confirm Changes page.
11. Click Finish to perform the global update.
A Global Change window opens, indicating the progress made as event data is updated. The amount of time necessary to complete this process depends on the amount of data to change and the number of events in the selected trees.
Once all changes are made, a window opens, indicating the number of events for which data was changed. You click OK to close the window.