Characters
|
Data Element Title
|
Data Source
|
---|---|---|
36
|
FAILURE MODE INDICATOR
|
Always set to F.
|
37-39
|
MODE NUMBER
|
If the Mode number field in the Generate LSAR File window is set to < Automatically generated > , the modes are numbered from 1 to n for each mode associated with an item. If a field from the FMEA Worksheet table is selected, the first three characters in this field are used. A common numbering scheme is 1A1, where:
• The first character represents the item
• The second character represents each unique failure mode for each item
• The third character represents the cause of failure for each failure mode
|
40-49
|
ENGINEERING FAILURE MODE MEAN TIME BETWEEN FAILURE (MTBF)
|
Displays the inverse of the value for the Mode Failure Rate field from the FMEA Worksheet table (1 / Mode Failure Rate).
|
50
|
ENGINEERING FAILURE MODE MEAN TIME BETWEEN FAILURE MEASUREMENT BASE
|
Always set to H.
|
51
|
FAILURE MODE CLASSIFICATION
|
Always set to O.
|
52-55
|
FAILURE MODE RATIO
|
Displays the value for the Mode Percentage field from the FMEA Worksheet table.
|