Parameter
|
Type
|
Description
|
---|---|---|
Quality Level
|
Choice List
|
The quality screening level used in the manufacturing of the device. The quality screening level used in the manufacturing of the device. Choices vary by subcategory. For more information, see MIL-HBDK-217 Quality Levels.
|
Type
|
Choice List [Parts Count also]
|
The type of device. Choices vary by subcategory.
|
Max Rated Temp
|
Choice List [FN1 only]
|
The maximum rated temperature of the device. Information about maximum rated temperatures for insulation classes follows this table.
|
Temp Rise to Hot Spot
|
Real (Degrees C)
|
The temperature rise from the subassembly to the hot spot temperature.
|
Hot Spot Temperature
|
Real (Degrees C)
|
Generally, this field is left at #.# so that the hot spot temperature is calculated as follows:
Hot Spot Temperature = Subassembly Temperature + Temperature Rise to Hot Spot
If you enter a value for this parameter, this value is used in place of a calculated hot spot temperature.
|
[Derating Parameters]
|
---
|
For more information, see Derating Parameters.
|
Specification
|
Insulation Class
|
|||||
---|---|---|---|---|---|---|
MIL-T-27
|
Q
|
R
|
S
|
V
|
T
|
U
|
MIL-T-21038
|
Q
|
R
|
S
|
T
|
U
|
V
|
MIL-T-55631
|
O
|
A
|
B
|
C
|
---
|
---
|
Max Rated Temp. (Degrees C)
|
85
|
105
|
130
|
155
|
170
|
170
|