Current Parameters
Current parameters are entered for many different part types in the Prediction Data pane. The following table describes all current parameters that can appear. If they are not required for a particular part type, either that parameter is not shown or an exception is noted in the Prediction Data pane.
Parameter
Type
Description
Operating Current
Real (Amps)
The operating load stress of the device in the circuit.
Rated Current
Real (Amps)
The maximum rated current of the device with a resistive load.
Current Ratio
Real
Generally, this field is left at #.#. The current ratio is calculated as follows:
Current Ratio = (Operating Current / Rated Current) * 100
If you enter a value for this parameter, this value is used in place of a calculated current ratio.
Rated Forward Current
Real (Amps)
The maximum rated forward rms current of the device.
Forward Peak Current
Real (Amps)
The peak forward current of the device.
Peak Current
Real (Amps)
The peak current that the device experiences.