Test Plan Pane
When an accelerated test plan is selected in the LDA Navigator, you supply input data in the Test Plan pane and then calculate to view results under Results. To quickly calculate results for the test plan, you click the Calculate button in the title bar of the Evaluate Test Plan pane.
Calculate Button
The following table describes the parameters that appear under Input in the Test Plan pane.
Parameter
Description
Input
The parameters under this heading supply input data for the test plan.
Stress count
Specifies the number of stresses used in the accelerated testing. Choices are 1 or 2. The default is 1. The selection you make here determines how may rows display in the table immediately below. In this table, you enter stress values.
Stress values
The table in which to enter stress data. Depending on whether 1 or 2 is selected for Stress count, the table contains either one row or two rows. In each row, you select a life stress model and enter stress values. Because these values are calculation inputs, they cannot be blank. Only non-negative values can be entered. Descriptions of table columns follow.
Stress Relation. The life stress model to use to evaluate stress data. Choices are Arrhenius, Exponential, and Power. The default is Exponential.
Usage Stress. The normal stress that the system experiences when it runs. The value must be greater than or equal to 0.
Highest Stress. The maximum stress experienced during accelerated testing. The value must be greater than the value entered for usage stress.
Distribution
The lifetime distribution of the component. When either Weibull or Lognormal is selected, a field for specifying the shape parameter is shown to the right. The value must be greater than 0. The default is 2.
For Weibull, β is the shape parameter.
For Lognormal, σ is the shape parameter.
Test plan
The criteria by which to analyze the test plan. Choices vary based on whether 1 or 2 is selected for Stress count.
Choices for one stress are:
2 Level Statistically Optimum Plan
3 Level Best Standard Plan
3 Level Best Compromise Plan
3 Level Best Equal Expected Number Failing Plan
3 Level 4:2:1 Allocation Plan
Choices for two stresses are:
3 Level Optimum Plan
5 Level Best Compromise Plan
Proportion of units at mid stress
The percent of units that should be tested at the middle stress level. This parameter is shown only when 3 Level Best Compromise Plan is selected for Test plan.
Optimum low stress reduction factor
The value to use to adjust the 3 level 4:2:1 allocation plan. This parameter is shown only when 3 Level 4:2:1 Allocation Plan is selected for Test plan. The low stress level of this plan is multiplied by the value entered here. The product is then used as the low stress level for the test, and the middle stress level is readjusted to be as close as possible to halfway between the low and high stress levels. To get an unadjusted plan, you would enter a value of 1.
Units on test
Indicates whether the number of units tested is available. When this checkbox is cleared (default), the number of units is not entered. When it is selected, a field becomes available to the right for entering the number of units. The value must be greater than or equal to 0. The default is 100.
Test duration
The number of hours that the test runs. The value must be greater than or equal to 0. The default is 100.
Test parameter type
Indicates the criteria to find the time of interest to which variance is minimized. Choices are Unreliability and Life Stress Parameters. The default is Unreliability. The selection you make here determines the prefix shown in the names for the stress parameters that appear below Usage level unreliability criterion.
When Unreliability is selected, Unreliability appears in the names.
When Life Stress Parameters is selected, η (eta) appears in the names when either the Weibull or exponential distribution is selected, and μ (mu) appears in the names when the lognormal distribution is selected.
Usage level unreliability criterion
A percentage value that indicates the unreliability of the system at the usage stress level.
When Unreliability is selected, the default is 0.10. The valid range is 0 to 1. If you enter a value outside this range, a window opens, indicating why it is invalid. When you click OK, the default value is shown once again.
When Life Stress Parameters is selected, the value is display-only. For the Weibull distribution, 0.632121 is the corresponding unreliability value. For the lognormal distribution, 0.5 is the corresponding unreliability value.
[stress parameters]
As indicated earlier, your selection for Test parameter type determines the prefix shown for stress and their default values. Your selection for Stress count determines the number of required parameters. The unreliability for the highest stress cannot be less than the unreliability for the usage stress. The life stress parameter for the highest stress cannot be greater than the life stress parameter for the usage stress.
For a single stress, two parameters are required.
(usage stress). The default is 0.20 when Unreliability is selected and 0 when Life Stress Parameters is selected.
(highest stress). The default is 0.40 when Unreliability is selected and 0 when Life Stress Parameters is selected.
For two stresses, three parameters are required.
(usage 1, usage 2). The default is 0.20 when Unreliability is selected and 0 when Life Stress Parameters is selected.
(highest 1, usage 2). The default is 0.40 when Unreliability is selected and 0 when Life Stress Parameters is selected.
(usage 1, highest 2). The default is 0.60 when Unreliability is selected and 0 when Life Stress Parameters is selected.
Results
Prior to calculating the input data, the following message is shown in the table beneath this heading: There are no results to display. Once the input data is calculated, results for low and high stress levels are shown. One row exists for each stress level, with the number of levels noted in the selection for Test plan. For example, when 3 Level Best Compromise Plan is selected, the table has three rows. Column descriptions follow.
Stress 1
The first stress used in the accelerated test plan.
Stress 2
The second stress used in the accelerated test plan. This column is shown only when 2 is selected for Stress count to indicate that two stresses are applied.
Portion Units
The proportion of units tested at the stress level or, for two stresses, the stress level combination.
Units on Test
This column is shown only when Units on test is selected when the input data was calculated.
Unreliability
Excel and Print Buttons
You use the Excel and Print buttons beneath the table to save results to a Microsoft Excel spreadsheet and print them to a printer. For more information, see Excel and Print Buttons.
Additional results
Once the accelerated test plan is calculated, additional display-only results are shown beneath the table. The last two results, Total time and Standard deviation, are shown only when Units on test was selected when the input data was calculated.
Time at unreliability
The time at the unreliability corresponding to the usage stress.
Total time
The expected total test time of all components at all stress levels.
Standard deviation
The standard deviation of the time at unreliability.