Auditing Changes to ESI Target Object
Changes to the ESITarget object such as create, delete and update can be audited by modifying the following file:
<Windchill>/conf/auditing/configAudit.xml
Add the following lines:
<ConfigEntry class="com.ptc.windchill.esi.tgt.ESITarget" enabled="true">
<KeyedEventEntry eventKey="*/wt.events.summary.CreateSummaryEvent/" enabled="true" handler="wt.audit.configaudit.DefaultAuditEventRecorder"/>
<KeyedEventEntry eventKey="*/wt.events.summary.DeleteSummaryEvent/" enabled="true" handler="wt.audit.configaudit.DefaultAuditEventRecorder"/>
<KeyedEventEntry eventKey="*/wt.events.summary.ModifySummaryEvent/" enabled="true" handler="wt.audit.configaudit.DefaultAuditEventRecorder"/>
</ConfigEntry>
Then restart the Windchill server.
Auditing can be stopped by setting enabled to false for individual events. Restart the server after making these modifications to the file.