설치 및 업그레이드 > 업그레이드 안내서 > The Windchill Upgrade Procedure > Stage the Source Data for the Upgrade > Configuring Windchill Business Reporting for Upgrade
  
Configuring Windchill Business Reporting for Upgrade
The Cognos component of Windchill Business Reporting requires additional steps prior to upgrading. Perform the following steps:
1. Stop the Cognos Service in silent mode. See the IBM Cognos Business Intelligence Installation and Configuration Guide for more details.
2. Copy the file cogstartup.xml, exported previously during the steps titled Preparing Windchill Business Reporting for Upgrade, to <WBR_HOME>/configuration.
3. Open the cogstartup.xml file and make the following changes:
Change DSA to RSA.
In the <crn:instance name="Cognos 8" class="Medium"> string, change Cognos 8 to Cognos.
4. Point the Cognos installation to the Cognos Schema of the source server (imported into a new SID).
Open the Cognos configuration. Click Data Access > Content Manager > Database child node and edit the appropriate values from Resource Properties.
5. Change the Administrative DN through the Cognos configuration.
a. Open Cognos Configuration, click Security > Authentication > Administrative Ldap and change the Base DN appropriately. This should be changed to match the Base DN of the source system.
b. (This step is not required if your Cognos version on the source system is 8.4.1). For the AdministrativeLDAP namespace, change the value of User lookup from “(uid=${environment("REMOTE_USER")})” to “uid=${userID}”.
6. Rename the CSK, signkeypair and encryptkeypair directories from the <WBR_HOME>/configuration directory.
7. If the Cognos admin username and password are different on the source system and the Target system, execute the following commands:
xconfmanager -s wt.cognos.admin.uid=<NEW_USERNAME> -t db/db.properties -p
xconfmanager -s wt.cognos.admin.password=<NEW_PASSWORD> -t db/db.properties -p
8. Open the Cognos Configuration. From Local Configuration > Environment, change all of the URIs appropriately:
Gateway Settings: Gateway URI, Dispatcher URIs for gateway & controller URIs for gateway
Dispatcher Settings: External Dispatcher URI, Internal Dispatcher URI
Other URI Settings: Dispatcher URIs for external applications, Content Manager URIs
For Cognos 11, the values for Gateway URI, Dispatcher URI for gateway and Dispatcher URI for external applications should be as follows:
Name
Values
Gateway URI
http://<host>:<port>/Cognos/bi/v1/disp
Dispatcher URI for gateway
http://<host>:<port>/bi/v1/disp
Dispatcher URI for external applications
http://<host>:<port>/bi/v1/disp
Use the following screen as an example:
9. Start the Cognos service.
10. On startup of the service, a pop-up appears asking for the upgrade report specification. Check the box and click OK. This will upgrade the old report with the new Cognos specifications. The following screenshot shows an example of this pop-up:
11. Configure Apache for Cognos (See the Windchill 설치 및 구성 안내서 for more information).
12. Verify that the Cognos service is running before running the Windchill Upgrade Manager.