Personalización avanzada > Business Logic Customization > Data Exchange using Standards in Windchill > STEP Data Exchange using EXPRESS > PLCS Data Exchange > PLCS / AP239 Mapping Implementation
  
PLCS / AP239 Mapping Implementation
ISO 10303-239 Product Life Cycle Support (PLCS) specifies an information model that defines what information can be represented and exchanged to support a product through its life cycle. The information model is specified using the EXPRESS information modeling language. Because the information model defined by PLCS is a generic model supporting the whole life cycle of a product, its scope is wider than most applications, business processes, or single data exchanges. Consequently Data Exchange Specifications (DEXs) are developed by the OASIS Product Life Cycle Support (PLCS) Technical Committee members to support the usage of subsets of the model.
PLCS uses the standard DEX templates defined in Release 5.
Reference Data
Reference data must be defined for every property associated with a Windchill object.
There are some standard annotation-based properties which must be added to newly added reference data and libraries. For details on the various annotation properties, please refer “Guidance for PLCS RDL Developers” section in the PLCS Guide for Reference Data Developer guide.
Reference data us managed in Windchill solution using the ISO_12006_3VERSION_14 schema.
* 
The PLCS Guide for Reference Date Developer guide can be downloaded from the OASIS Product Life Cycle Support (PLCS) Technical Committee website from this external link: PLCS Guide for Reference Date Developer
AP239 / PLCS Configuration
This section describes how to configure AP239/PLCS based data exchange in Windchill.
1. Load Windchill Express schema.
2. PLCS schema-specific files can be found from the <Windchill>\codebase\registry\stepdex\ap239 folder. This is the <PLCS_HOME> folder.
3. Load the PLCS schema AP239E2_ARM_ASD_DEX_1_3_EXTENSION_lf.exp schema from the <PLCS_HOME>\schema directory. While loading the schema ensure that you have selected the “edm express extension” option.
4. Load the RDL schema, ISO_12006_3_VERSION_14.exp from the <PLCS_HOME>\rdl directory.
5. Load the following query schemas located in the <PLCS_HOME>\rdl\qex directory.
a. ifd_adapter.qex
b. ifd_wsdl_express_plcs.qex
c. define_hash_tables.qex
6. Create permanent hash tables by executing a query.
a. Navigate to Data > Query > Execute Query section in the EDMSuperviser.
b. Specify SystemRepository, DummyModel, define_hash_table, define_hash_tables as entries specific to the Repository, Model, Query Schema, and Query fields.
c. Select Ok.
7. Import the plcsrdl model from the plcsrdl.stp file located in the <PLCS_HOME>\rdl directory
8. Load import/export specific xpx files located in import/export specific folders in the <PLCS_HOME> location.
* 
These manual steps have been incorporated into ant scripts. They can found at:
<WT_HOME>\bin\configureAP239.xml
<WT_HOME>\bin\configureSTEP.xml
Handling Reference Data
The new PLCS RDL Editor should be used to add or update RDL. Refer to “Reference Manual” for usage of the RDL Editor. The Reference manual can be accessed either through Short cut or through the Help menu in the RDl Editor.
To add an RDL entry:
1. Load plcsrdlptc.stp present in <Windchill>\codebase\registry\stepdex\ap239\rdl using the P21 file import model from Models menu.
2. Select the relevant super type and add a “New child”. Add as many RDL entries as required.
3. Export the model to plcsrdlptc.stp file.
* 
Model can be loaded using OWLs as well.
Adding Attributes in PLCS
IBAs in PLCS format
IBAs in PLCS standard are represented by reference data. Every attribute on the business object is represented as reference data.
A IBA should be added first as reference data in PLCSRDL model. For more information see Handling Reference Data for information on how to add attribute to reference data.
Add an entry in attribute_to_rdl.properties for each attribute. The attribute_to_rdl.properties file is located in the <WT_HOME>\codebase\registry\stepdex\ap239\common\includes directory.
The attribute_to_rdl.properties is the file that relates attribute path to RDL entry (for example WTPart\name=urn:plcs:rdl:std:Part_name).
If the attribute is soft attribute, the softtype should be included in stepdex.properties. For more information see the “Supported Types” section in Business Field Mapping.
Reference Data Library Entities
This section contains tables which depict how various Windchill object-specific attributes are represented in a Reference Data Library (RDL). The following namespace conventions are used for representing PLCS and PTC reference data representation:
PTC stands for urn:plcs:rdl:ptc
PLCS stands for urn:plcs:std:rdl
Reference Data Entry
This section represents how certain common attributes present in various Windchill Objects such as WTPart or WTDocument are represented in an RDL.
Attribute
RD Entry
Parent RD
number
PLCS:Part_identification_code
PLCS:identification_code
Ufid
PTC:ufid
PTC:wtobject_identification_code
masterufid
PTC:masterufid
PTC:wtobject_identification_code
lifeCycleState
PTC:lifeCycleState
PTC:assigned_lifecycleInfo_property
lifeCycleName
PTC:lifeCycleName
PTC:assigned_lifecycleInfo_property
folderPath
PTC:folderPath
PLCS:Assigned_property
externalTypeId
PTC:externalTypeId
PLCS:Assigned_property
versionLevel
PTC:versionLevel
PLCS:Assigned_property
Reference Data Entries for WTPart
This section represents the snippet reference data hierarchy for WTPart specific attributes.
Attribute
RD Entry
Parent RD
partType
PTC:partType
PTC:assigned_wtpart_property
defaultUnit
PTC:defaultUnit
PTC:assigned_wtpart_property
endItem
PTC:endItem
PTC:assigned_wtpart_property
defaultTraceCode
PTC:defaultTraceCode
PTC:assigned_wtpart_property
domainName
PTC:domainName
PLCS:Assigned_property
genericType
PTC:genericType
PLCS:Assigned_property
partSource
PTC:partSource
PLCS:Assigned_property
partType
PTC:partType
PLCS:Assigned_property
view
PTC:view
PLCS:Assigned_property
Reference Data Entries for WTDocument
This section represents the snippet reference data hierarchy for WTDocument specific attributes.
Attribute
RD Entry
Parent RD
department
PTC:department
PLCS:Assigned_property
domainName
PTC:domainName
PLCS:Assigned_property
docTitle
PTC:docTitle
PLCS:Assigned_document_property
docType
PTC:docType
PLCS:Assigned_document_property
description
PLCS:Description
PLCS:Descriptor_assignment
Reference Data Entries for BusinessField Attributes
In PLCS, attribute name and unit values are usually referred with a specific Reference Data (RD) entry. Since users define attributes on production system, it is suggested that you create your own RD-specific entry. For unit values, base unit-specific RD entries are already incorporated in the data exchange standards.
The following table depicts the common base unit’s specific RDL entries already incorporated into standard PLCS Import export-specific operation.
Unit Name
RD Entry
Parent RD
M
PLCS: m_Length_unit
Context_dependent_unit and Length_unit
G
PLCS : g_Mass_unit
Context_dependent_unit and Mass_unit
S
PLCS:Time_unit
Time_unit
A
PLCS:A_ Electric_current_unit
Context_depdendent_unit and Electric_current_unit
K
PLCS: K_Thermodynamic_temperature_unit
Context_dependent_unit and Thermodynamic_temperature_unit
Mol
PLCS: mol_Amount_of_substance_unit
Context_dependent_unit and : Amount_of_substance_unit
Cd
PLCS: cd_Luminous_intensity_unit
Context_dependent_unit and : Luminous_intensity_unit
R
PLCS: r_Plane_angle_unit
Context_dependent_unit and : Plane_angle_unit
Sr
PLCS: sr_Solid_angle_unit
Context_dependent_unit and : Solid_angle_unit
Base units other than above 9 standard units.
PLCS: Context_dependent_unit
Units with Multiplication or exponent or division
PLCS:Derived_unit
* 
Base units are simple units without having any multiplication, exponent or division symbols whereas derived units are units which are generated from base units. Business field names are configured against Assigned_property parent class. Only for time based business field parent should be Date or Date_and_time_assignment class.
Reference Data Entries for Representation
The following table details the snippet reference data hierarchy for representation-specific attributes.
Attribute
RD Entry
Parent RD
derivationType
PTC:derivationType
PLCS:Assigned_property
ClassName
PTC:ClassName
PLCS:Assigned_property
default
PTC:default
PLCS:Assigned_property
republishable
PTC:republishable
PLCS:Assigned_property
representationType
PTC:representationType
PLCS:Assigned_property
hasBoundingBox
PTC:hasBoundingBox
PLCS:Assigned_property
boundingBox
PTC:boundingBox
PLCS:Assigned_property
hasOctree
PTC:hasOctree
PLCS:Assigned_property
Octree
PTC:octree
PLCS:Assigned_property
repContentId
PTC:repContentId
PLCS:Assigned_property
Derived_image
PTC:Derived_image
PLCS:Document_assignment