Administración de la empresa > Implementación de Windchill ESI > Implementing Windchill ESI in an SAP Environment > SAP API Structures > Allocate Control Characteristic (MIC) to Part (Material)
  
Allocate Control Characteristic (MIC) to Part (Material)
The following API structure tables list all the APIs and the respective API fields that are required to allocate MIC to Material within the current version of SAP distribution targets.
ZRFC_MAINTAIN_MAT_SPEC
SAP does not provide standard BAPIs to allocate MIC to Material. This custom RFC has been developed using the BDC method provided by SAP, which records the screen and its' fields, which are used to fill the values on the screen.
Windchill Attribute Name
API Structure
API Field
API Field Description
Value (If default used)
Source
Transform
Material Number
MATERIAL
Material Number
N/A
Windchill
N/A
DEL_MIC
Delete inspection characteristic
X
TIBCO
N/A
INS_MIC
Insert inspection characteristic
X
TIBCO
N/A
Control Characteristic Version
T_DELETE_INSP_CHAR
VERSION
Control Characteristic Version
N/A
Windchill
N/A
Control Characteristic Number
T_DELETE_INSP_CHAR
MIC
Control Characteristic Number
N/A
Windchill
N/A
T_DELETE_INSP_CHAR
PLANT_MIC
Plant
N/A
Windchill
N/A
Model Item Reference/ Target Value
T_DELETE_INSP_CHAR
TARGET_VAL
Target Value
N/A
Windchill
N/A
Model Item Reference/ Upper Target Value
T_DELETE_INSP_CHAR
UP_TOL_LMT
Upper Target Value
N/A
Windchill
N/A
Model Item Reference/ Lower Target Value
T_DELETE_INSP_CHAR
LW_TOL_LMT
Lower Target Value
N/A
Windchill
N/A
Control Characteristic Version
T_INSERT_INSP_CHAR
VERSION
Control Characteristic Version
N/A
Windchill
N/A
Control Characteristic Number
T_INSERT_INSP_CHAR
MIC
Control Characteristic Number
N/A
Windchill
N/A
T_INSERT_INSP_CHAR
PLANT_MIC
Plant
N/A
Windchill
N/A
Model Item Reference/ Target Value
T_INSERT_INSP_CHAR
TARGET_VAL
Target Value
N/A
Windchill
N/A
Model Item Reference/ Upper Target Value
T_INSERT_INSP_CHAR
UP_TOL_LMT
Upper Target Value
N/A
Windchill
N/A
Model Item Reference/ Lower Target Value
T_INSERT_INSP_CHAR
LW_TOL_LMT
Lower Target Value
Windchill
N/A