Publishing a PDF or Graphical Structure from a Parts List
The following lists prerequisites for publishing:
• You must have Windchill Service Parts installed on Windchill.
• A Parts List Information Element for a product must be set up in Windchill and used in a publication structure.
• A WVS SIS Worker must be set up in Windchill. Refer to
• A Windchill Visualization Services publishing rule must be set up in Windchill.
• If the content of a parts list referenced by a parts list information element is filtered with Options and/or Service Effectivity filters, only parts that meet the filter criteria are included when the parts list is published.
• For information on publishing setup, refer to Configuring Windchill Service Information Manager and Windchill Service Parts, available from the Windchill Help Center or the PTC Reference Documents site at:
In the Navigator pane, choose a Windchill Service Information Manager product that contains a parts list information element in a publication structure folder.
The instructions for publishing a Parts List Information Element depend on where the Parts List is being published.
Publishing from the Publication Structure tab:
1. Expand the product and open the Publication Structures folder.
2. On the Publication Structures page, choose a publication structure from the list and open it.
3. On the Publication Structures information page, choose the Structure tab.
4. Find a Parts List Holder
and select it.
5. From the
Actions menu, choose
Publish Representation. The
Publish Representation window opens.
and determine whether you want the representation to be the default.
7. Click Submit Publish Job.
Publishing from the Parts List Editor page:
1. Expand the product and open the Publication Structures folder.
2. On the Publication Structures page, choose a publication structure from the list and open it.
3. On the Publication Structures page, choose the Structure tab.
4. Find a Parts List Holder
and select it.
5. On the toolbar under
Tools, expand the
Open in menu and choose
Open Content in Parts List Editor.
6. On the Parts List page, right click to display the context menu and choose
Publish Representation. The
New Representation window opens.
7. In the New Representation window, provide a Name and Description. Choose one of the following types:
◦ Parts List Structure — Creates a PVZ representation of the parts list. Check Set as Default if you would like this to be the default representation that displays in the Details tab.
◦ Published Parts List — Creates an output representation of the parts list based on the rule specified with Publishing Rule. If your Administrator has not set up publishing rules, PDF is chosen by default.
8. Click Next and choose the configuration specification.
Choose the configuration of the objects used in your object that you want published in your representation. If you want the most recent version, for example, choose
Latest. For more information, see
About Configuration Specifications.
9. When you are finished, click Submit Publish Job. A confirmation message displays stating that the job was submitted.
| You can monitor the progress of your job through the WVS Job Monitor. To access the WVS Job Monitor, click the WVS Job Monitor link in the confirmation message. |